Adsorption stripping voltammetry of phenol at Nafion-modified glassy carbon electrode in the presence of surfactants

被引:131
|
作者
Yi, HC
Wu, KB
Hu, SS [1 ]
Cui, DF
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[2] Hubei Agr Coll, Dept Food Sci, Jinzhou 434103, Peoples R China
[3] Chinese Acad Sci, State Key Lab Transducer Technol, Inst Elect, Beijing 100080, Peoples R China
关键词
adsorption stripping voltammetry; phenol; Nafion; cetyltrimethylammonium bromide;
D O I
10.1016/S0039-9140(01)00531-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a new voltammetric method for the determination of phenol is described. In pH 8.00 phosphate buffer and in the presence of long-chain cationic surfactant-cetyltrimethylammonium bromide-phenol has a very sensitive oxidation peak at 0.47 V (vs. SCE) on the Nafion-modified glassy carbon electrode (GCE). The experimental parameters, such as supporting electrolyte and pH values, amounts of Nafion, varieties and concentration of surfactants, accumulation potential and time, as well as scan rate were optimized. The peak current is linear with the concentration of phenol in the range from 8 x 10(-9) to 1 x 10(-5) M, and the detection limit is 1 x 10(-9) M after being accumulated at - 0.50 V (vs. SCE) for 3 min. Trace levels of phenol in water samples were determined by using this voltammetric method, the average recovery was calculated to be 99.56%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1205 / 1210
页数:6
相关论文
共 50 条
  • [1] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [2] Nafion-modified glassy carbon electrode for trace determination of indium
    Xiang, CL
    Zou, YJ
    Xie, JJ
    Fei, XM
    Li, JH
    ANALYTICAL LETTERS, 2005, 38 (13) : 2045 - 2055
  • [3] Voltammetric behavior and determination of estrogens at Nafion-modified glassy carbon electrode in the presence of cetyltrimethylammonium bromide
    Hu, SS
    Wu, KB
    Yi, HC
    Cui, DF
    ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 209 - 216
  • [4] Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid
    Vu Thi Huong
    Toshinori Shimanouchi
    Do Phuc Quan
    Hiroshi Umakoshi
    Pham Hung Viet
    Ryoichi Kuboi
    Journal of Applied Electrochemistry, 2009, 39 : 2035 - 2042
  • [5] Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid
    Huong, Vu Thi
    Shimanouchi, Toshinori
    Quan, Do Phuc
    Umakoshi, Hiroshi
    Viet, Pham Hung
    Kuboi, Ryoichi
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (10) : 2035 - 2042
  • [6] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Marcelina Łysoń
    Anna Górska
    Beata Paczosa-Bator
    Robert Piech
    Electrocatalysis, 2021, 12 : 641 - 649
  • [7] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Lyson, Marcelina
    Gorska, Anna
    Paczosa-Bator, Beata
    Piech, Robert
    ELECTROCATALYSIS, 2021, 12 (06) : 641 - 649
  • [8] Anodic stripping voltammetry of arsenic determination with edible mushroom-nafion-modified glassy carbon electrode
    Salinas, Arturo
    Trivino, Juan Jose
    Alvarez-Lueje, Alejandro
    Pizarro, Isabel
    Segura, Rodrigo
    Arancibia, Veronica
    TALANTA, 2024, 277
  • [9] DETERMINATION OF ADENINE BY CHRONOPOTENTIOMETRIC STRIPPING ANALYSIS WITH NAFION-MODIFIED ELECTRODE
    JIN, LT
    LIU, SH
    BAI, ZP
    FANG, YZ
    ELECTROANALYSIS, 1993, 5 (07) : 611 - 614
  • [10] Cadmium determination in phosphate fertiliser using a PAN-Nafion® modified glassy carbon electrode by stripping voltammetry
    Phaisansuthichol, Sirirat
    Ratana-ohpas, Roongroje
    Dejmanee, Saravut
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (07) : 783 - 796