Water-cooling diamond anvil cells: An approach to temperature-pressure relation in heated experiments

被引:2
作者
Zhang, Yanan [1 ]
Wu, Yue [2 ]
Han, Yonghao [1 ]
Gao, Yang [3 ]
机构
[1] Jilin Univ, State Key Lab Superhard Mat, Changchun 130012, Peoples R China
[2] Weinan Vocat & Tech Coll, Weinan 714026, Peoples R China
[3] Ctr High Pressure Sci & Technol Adv Res, Shanghai 201203, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
X-RAY-DIFFRACTION; CALIBRATION; RUBY; GAUGE; SENSOR; SYSTEM; GPA;
D O I
10.1063/5.0099202
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Temperature induced pressure drift in the diamond anvil cell (DAC) is a major issue in high-pressure high-temperature experiments. It is commonly acknowledged that these drifts originate from multiple factors, but no systematic descriptions have been made so far. By introducing an internal water-cooling system in the DAC, we have performed a systematic investigation into temperature induced pressure drifts to reveal the mechanism behind them and to find a proper experimental procedure to achieve minimal pressure variation in DAC's heating experiment. It is revealed in this experiment that pressure variation during heating processes originates from multiple temperature related factors of the DAC. The variation itself can be considered as a rebalancing process of the compression forces on the sample chamber initiated by the disturbance caused by temperature elevation. It is possible to suppress pressure variation by maintaining the temperature of the DAC body at room temperature to ensure the consistency of compression on the sample chamber. At the same time, the best procedure for the heating experiments is to properly pre-heat the sample chamber equipped with the internal water-cooling system before performing the in situ measurements on the temperature-related properties at the pressurized and heated conditions. Our discovery provides a reliable procedure for the sample heating process in the DAC and helps resolve the complex mystery of the influence of the combination of pressure and temperature in high-pressure high-temperature experiments. Published under an exclusive license by AIP Publishing.
引用
收藏
页数:9
相关论文
共 31 条
[1]   OPTICAL FLUORESCENCE SYSTEM FOR QUANTITATIVE PRESSURE MEASUREMENT IN DIAMOND-ANVIL CELL [J].
BARNETT, JD ;
BLOCK, S ;
PIERMARINI, GJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (01) :1-9
[2]   A NEW DIAMOND-ANVIL CELL FOR HYDROTHERMAL STUDIES TO 2.5 GPA AND FROM - 190-DEGREES-C TO 1200-DEGREES-C [J].
BASSETT, WA ;
SHEN, AH ;
BUCKNUM, M ;
CHOU, IM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (08) :2340-2345
[3]   TEMPERATURE-MEASUREMENT IN LASER HEATED DIAMOND ANVIL CELLS [J].
BASSETT, WA ;
WEATHERS, MS .
PHYSICA B & C, 1986, 139 (1-3) :900-902
[4]   The ruby pressure standard to 150 GPa [J].
Chijioke, AD ;
Nellis, WJ ;
Soldatov, A ;
Silvera, IF .
JOURNAL OF APPLIED PHYSICS, 2005, 98 (11)
[5]   Improved calibration of the SrB4O7:Sm2+ optical pressure gauge: Advantages at very high pressures and high temperatures [J].
Datchi, F ;
LeToullec, R ;
Loubeyre, P .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) :3333-3339
[6]   High-pressure/high-temperature phase diagram of zinc [J].
Errandonea, D. ;
MacLeod, S. G. ;
Ruiz-Fuertes, J. ;
Burakovsky, L. ;
McMahon, M., I ;
Wilson, C. W. ;
Ibanez, J. ;
Daisenberger, D. ;
Popescu, C. .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2018, 30 (29)
[7]   PRESSURE MEASUREMENT MADE BY UTILIZATION OF RUBY SHARP-LINE LUMINESCENCE [J].
FORMAN, RA ;
BLOCK, S ;
BARNETT, JD ;
PIERMARINI, GJ .
SCIENCE, 1972, 176 (4032) :284-+
[8]   Cubic boron nitride as a primary calibrant for a high temperature pressure scale [J].
Goncharov, Alexander F. ;
Sinogeikin, Stanislav ;
Crowhurst, Jonathan C. ;
Ahart, Muhtar ;
Lakshtanov, Dmitry ;
Prakapenka, Vitali ;
Bass, Jay ;
Beck, Pierre ;
Tkachev, Sergei N. ;
Zaug, Joseph M. ;
Fei, Yingwei .
HIGH PRESSURE RESEARCH, 2007, 27 (04) :409-417
[9]  
Hess N.J., 1989, High Pressure Research, V2, P57
[10]   COMPARISON OF THE PRESSURE-INDUCED FREQUENCY-SHIFT OF SM-YAG TO THE RUBY AND NITROGEN VIBRON PRESSURE SCALES FROM 6-K TO 820-K AND 0 TO 25 GPA AND SUGGESTIONS FOR USE AS A HIGH-TEMPERATURE PRESSURE CALIBRANT [J].
HESS, NJ ;
SCHIFERL, D .
JOURNAL OF APPLIED PHYSICS, 1992, 71 (05) :2082-2086