Weighted least squares for point-based registration in digital subtraction angiography (DSA)

被引:0
|
作者
Buzug, TM [1 ]
Weese, J [1 ]
Lorenz, C [1 ]
机构
[1] Univ Appl Sci Remagen, D-53424 Remagen, Germany
来源
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2 | 1999年 / 3661卷
关键词
digital subtraction angiography; template matching; registration; similarity measure; weighted least squares;
D O I
10.1117/12.348540
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Four main problems have to be solved for template matching based motion compensation in digital subtraction angiography. All the problems are concerned with the similarity measure that is the objective function to be optimized within the template matching procedure: 1) Due to the injection of contrast agent, mask and contrast image are dissimilar, which degrades the quality of some similarity measures. 2) Homogeneous areas in the fluoroscopic images lead to an insufficient quality of the similarity measure. 3) Shift invariant structures in fluoroscopic images (e.g. straight lines or edges) lead to a ridge-like objective function that potentially gives wrong results from the optimization procedure: If a ridge-like structure of the objective function is present movements along this direction cannot be detected. Therefore, the local accuracy of the estimated motion component parallel to these directions must be ranked low while the corresponding orthogonal direction must be ranked high. We here present a technique to obtain local, directional rankings from the shape of the objective function which especially improves the quality of DSA images obtained from peripheral areas like the shinbone. 4) Inhomogeneous movements inside a single template lead to ambiguous or even irrelevant optima of the objective function: This problem is out of the scope of the present paper and will therefore not be addressed here. The performance of the point-based registration using different weightings in the least squares procedure (equally, isotropic and anisotropic weighting) has been compared. The isotropic and anisotropic weighting turned out to be superior to the equally weighted least squares procedure.
引用
收藏
页码:139 / 150
页数:12
相关论文
共 50 条
  • [1] Image registration based on weighted histogram for digital subtraction angiography
    Chu, Ying
    Mi, Hua
    Ji, Zhen
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2008, 36 (07): : 1344 - 1348
  • [2] DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) OF THE LUNG
    HARDER, T
    LACKNER, K
    VATTER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1984, 140 (04): : 425 - 430
  • [3] DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) OF THE AORTA
    HARDER, T
    SCHLOLAUT, KH
    LACKNER, K
    KOSTER, O
    QUADE, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1986, 145 (04): : 420 - 427
  • [4] An improved subtraction algorithm in Digital Subtraction Angiography (DSA)
    Jiang, LH
    Chai, ZM
    Sun, HS
    CHINESE JOURNAL OF ELECTRONICS, 2000, 9 (02): : 185 - 188
  • [6] DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) IN THE UPPER EXTREMITY
    HARDER, T
    LACKNER, K
    FRANKEN, T
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1983, 139 (06): : 609 - 615
  • [7] TECHNICAL ASPECTS OF DIGITAL SUBTRACTION ANGIOGRAPHY (DSA)
    MEANEY, TF
    ANNALES DE RADIOLOGIE, 1983, 26 (07) : 615 - 615
  • [8] Image registration for digital subtraction angiography
    Meijering, EHW
    Zuiderveld, KJ
    Viergever, MA
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 1999, 31 (2-3) : 227 - 246
  • [9] Image Registration for Digital Subtraction Angiography
    Erik H.W. Meijering
    Karel J. Zuiderveld
    Max A. Viergever
    International Journal of Computer Vision, 1999, 31 : 227 - 246
  • [10] DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) OF RENAL-TRANSPLANTS
    MEANEY, TF