Residual Stress Impairs Pump Function After Surgical Ventricular Remodeling: A Finite Element Analysis

被引:4
|
作者
Pantoja, Joe Luis
Zhang, Zhihong
Tartibi, Mehrzad
Sun, Kay
Macmillan, Warrick
Guccione, Julius M.
Ge, Liang
Ratcliffe, Mark B.
机构
[1] Univ Calif San Francisco, Dept Surg, San Francisco, CA USA
[2] Univ Calif San Francisco, Dept Bioengn, San Francisco, CA 94143 USA
[3] Vet Affairs Med Ctr, San Francisco, CA 94121 USA
关键词
REDUCTION SURGERY; MODEL; ANEURYSM; RESTORATION; MECHANICS; MYOCARDIUM; MUSCLE;
D O I
10.1016/j.athoracsur.2015.05.119
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Surgical ventricular restoration (Dor procedure) is generally thought to reduce left ventricular (LV) myofiber stress (FS) but to adversely affect pump function. However, the underlying mechanism is unclear. The goal of this study was to determine the effect of residual stress (RS) on LV FS and pump function after the Dor procedure. Methods. Previously described finite element models of the LV based on magnetic resonance imaging data obtained in 5 sheep 16 weeks after anteroapical myocardial infarction were used. Simulated polyethylene terephthalate fiber (Dacron) patches that were elliptical and 25% of the infarct opening area were implanted using a virtual suture technique (VIRTUAL-DOR). In each case, diastole and systole were simulated, and RS, FS, LV volumes, systolic and diastolic function, and pump (Starling) function were calculated. Results. VIRTUAL-DOR was associated with significant RS that was tensile (2.89 +/- 1.31 kPa) in the remote myocardium and compressive (234.15 +/- 65.53 kPa) in the border zone. VIRTUAL-DOR+RS (compared with VIRTUAL-DOR-NO-RS) was associated with further reduction in regional diastolic and systolic FS, with the greatest change in the border zone (43.5-fold and 7.1-fold, respectively; p < 0.0001). VIRTUAL-DOR+RS was also associated with further reduction in systolic and diastolic volumes (7.9%; p = 0.0606, and 10.6%; p = 0.0630, respectively). The resultant effect was a further reduction in pump function after VIRTUAL-DOR+RS. Conclusions. Residual stress that occurs after the Dor procedure is positive (tensile) in the remote myocardium and negative (compressive) in the border zone and associated with reductions in FS and LV volumes. The resultant effect is a further reduction in LV pump (Starling) function. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:2198 / 2205
页数:8
相关论文
共 50 条
  • [21] Finite element formulation and analysis for an arterial wall with residual and active stresses
    Kida, Naoki
    Adachi, Taiji
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (11) : 1143 - 1159
  • [22] Prediction of Tablet Characteristics from Residual Stress Distribution Estimated by the Finite Element Method
    Hayashi, Yoshihiro
    Miura, Takahiro
    Shimada, Takuya
    Onuki, Yoshinori
    Obata, Yasuko
    Takayama, Kozo
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2013, 102 (10) : 3678 - 3686
  • [23] Reduction of Residual Stress for High-Strength Low-Alloy Steel Strip Based on Finite Element Analysis
    Qiu, Zengshuai
    He, Anrui
    Shao, Jian
    Xia, Xiaoming
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [24] Finite element analysis of the thermal residual stress distribution in the interphase of unidirectional fiber-reinforced resin matrix composites
    Guo, Yu
    Wang, Yanqing
    Guo, Gangye
    Xie, Yaoshe
    COMPOSITE INTERFACES, 2018, 25 (09) : 823 - 838
  • [25] Why is the surgical ventricular restoration operation effective for ischemic cardiomyopathy? Geometric analysis with magnetic resonance imaging of changes in regional ventricular function after surgical ventricular restoration
    Yu, Hsi-Yu
    Chen, Yih-Sharng
    Tseng, Wen-Yih
    Chi, Nai-Shin
    Wang, Chih-Hsien
    Wang, Shoei-Shen
    Lin, Fang-Yue
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) : 887 - 894
  • [26] Stress Distribution with Different Restorations in Teeth with Curved Roots: A Finite Element Analysis Study
    Chatvanitkul, Chayanee
    Lertchirakarn, Veera
    JOURNAL OF ENDODONTICS, 2010, 36 (01) : 115 - 118
  • [27] Finite element stress analysis of the hindfoot after medial displacement calcaneal osteotomy with different translation distances
    Lyu, Jinyang
    Xu, Jian
    Huang, Jiazhang
    Zhang, Chao
    Wang, Xu
    Yu, Jian
    Ma, Xin
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2025,
  • [28] Pathogenesis of Acute Aortic Dissection: A Finite Element Stress Analysis
    Nathan, Derek P.
    Xu, Chun
    Gorman, Joseph H., III
    Fairman, Ron M.
    Bavaria, Joseph E.
    Gorman, Robert C.
    Chandran, Krishnan B.
    Jackson, Benjamin M.
    ANNALS OF THORACIC SURGERY, 2011, 91 (02) : 458 - 463
  • [29] Finite element analysis of wall stress in the equine pulmonary artery
    Teeter, M. G.
    Arroyo, L. G.
    Bakker, J. D.
    Hayes, M. A.
    Viel, L.
    Runciman, R. J.
    EQUINE VETERINARY JOURNAL, 2010, 42 (01) : 68 - 72
  • [30] The Finite Element Analysis on the Stress of Strapless Bra When Worn
    Qi, Jing
    Zhang, Shi-Chen
    Zhang, Xin
    Ying, Bo-An
    TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, 2015, 2015, : 96 - 104