Thermal Performance Evaluation of a Double Pipe Heat Exchanger Installed in a Biomass Gasification System

被引:8
作者
Nwokolo, Nwabunwanne [1 ]
Mukumba, Patrick [1 ]
Obileke, KeChrist [1 ]
机构
[1] Univ Ft Hare, Dept Phys, PBag X1314, ZA-5700 Alice, South Africa
来源
JOURNAL OF ENGINEERING | 2020年 / 2020卷
关键词
CONDUCTIVITY;
D O I
10.1155/2020/6762489
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Heat exchangers are widely used for heat recovery purposes in many industrial applications such as gasification systems. In a biomass gasification system situated at Melani village in Eastern Cape of South Africa, a significant quantity of heat energy is lost during syngas cooling. Thus, a heat exchanger was constructed and installed in the gasification system for the purpose of heat recovery. Therefore, the aim of this study is to evaluate the performance of the heat exchanger under variable operating conditions for counterflow and parallel flow configurations. The experimental investigation was carried out on a double pipe heat exchanger as the downdraft gasifier system operated on a wood consumption rate of 180 kg/h. The heat exchanger was installed at the exit point of the syngas in the gasifier, and water served as the cooling fluid. Inlet and outlet temperatures of the hot syngas and cooling water (fluids) were measured using thermocouples at variable flow rates. Experimental data were processed using energy equations to determine vital performance parameters (overall heat transfer coefficient, effectiveness, and log mean temperature difference). The findings showed that optimum heat exchanger effectiveness of 0.55 was determined at a mass flow rate of 0.07 kg/s. In addition, counterflow configuration was found to be approximately 14% more effective than the parallel flow configuration. This is attributed to the relative direction of the fluids in the configurations of both flows. The study recommends that double pipe heat exchanger is suitable for recovering heat from the gasification system.
引用
收藏
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 2012, INT J MODEL SIMUL SC
[2]  
[Anonymous], 2016, PLOS NEGLECT TROP D
[3]  
[Anonymous], 2018, ARCH MECH ENG, DOI DOI 10.24425/119408
[4]  
Chawdhury MA, 2013, J SCI RES, V3, P51
[5]   The effect of cyclone inlet dimensions on the flow pattern and performance [J].
Elsayed, Khairy ;
Lacor, Chris .
APPLIED MATHEMATICAL MODELLING, 2011, 35 (04) :1952-1968
[6]   Performance evaluation and exergy analysis of a double pipe heat exchanger under air bubble injection [J].
Heyhat, Mohammad Mahdi ;
Abdi, Adel ;
Jafarzad, Ali .
APPLIED THERMAL ENGINEERING, 2018, 143 :582-593
[7]  
Jain AK, 1999, J AGR ENG, V36, P27
[8]   Biomass gasification for district heating [J].
Kirsanovs, Vladimirs ;
Blumberga, Dagnija ;
Karklina, Katrina ;
Veidenbergs, Ivars ;
Rochas, Claudio ;
Vigants, Edgars ;
Vigants, Girts .
INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2016, 2017, 113 :217-223
[9]   Thermochemical Biomass Gasification: A Review of the Current Status of the Technology [J].
Kumar, Ajay ;
Jones, David D. ;
Hanna, Milford A. .
ENERGIES, 2009, 2 (03) :556-581
[10]   Thermal conductivity of gaseous and liquid n-hexane [J].
Le Neindre, B. ;
Lombardi, G. ;
Desmarest, P. ;
Kayser, M. ;
Sabirzianov, A. N. ;
Gabitov, F. R. ;
Gumerov, F. ;
Garrabos, Y. .
FLUID PHASE EQUILIBRIA, 2018, 474 :60-75