Net analyte preprocessing: a new and versatile multivariate calibration technique. Analysis of mixtures of rubber antioxidants by NIR spectroscopy

被引:17
作者
Boschetti, CE
Olivieri, AC
机构
[1] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Analit, RA-2000 Rosario, Santa Fe, Argentina
[2] Pecom Energia SA, Planta PGSM, Lab Certificac Calidad, Puerto Gen San Martin, Argentina
关键词
net analyte preprocessing; rubber antioxidants; tris-(nonylphenyl)-phosphite; 4,6-bis-(octylthiomethyl)-o-cresol;
D O I
10.1255/jnirs.310
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new multivariate calibration technique called net analyte preprocessing is introduced for the study of mixtures by near infrared spectroscopy. It involves the construction of a space spanned by all sources of variability except one component (or reference property). Both the data matrix and the unknown sample spectrum are preprocessed through a projection orthogonal to the latter space, yielding a set of net analyte signals appropriate for quantifying a particular mixture component. The construction of the net analyte space is carried out using a certain number of spectral factors, which can be estimated by cross-validation. Advantages of the presently discussed method include the estimation of figures of merit (sensitivity, selectivity and limit of determination) and the presentation of data in a useful pseudounivariate mode. An example involving the successful analysis of mixtures of the two rubber antioxidants tris-(nonylphenyl)-phosphite and 4,6-bis-(octylthiomethyl)-o-cresol is described, and compared with classical techniques such as principal component regression and partial least-squares.
引用
收藏
页码:245 / 254
页数:10
相关论文
共 24 条
  • [1] An enhanced algorithm for linear multivariate calibration
    Berger, AJ
    Koo, TW
    Itzkan, I
    Feld, MS
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (03) : 623 - 627
  • [2] THEORY OF ANALYTICAL-CHEMISTRY
    BOOKSH, KS
    KOWALSKI, BR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (15) : A782 - A791
  • [3] Multivariate detection limits estimators
    Boque, R
    Rius, FX
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (01) : 11 - 23
  • [4] Improving synthetic hindered phenol antioxidants:: learning from vitamin E
    Breese, KD
    Lamèthe, JF
    DeArmitt, C
    [J]. POLYMER DEGRADATION AND STABILITY, 2000, 70 (01) : 89 - 96
  • [5] COLE JO, 1954, SYNTHETIC RUBBER, P528
  • [6] Simultaneous spectrophotometric-multivariate calibration determination of several components of ophthalmic solutions: phenylephrine, chloramphenicol, antipyrine, methylparaben and thimerosal
    Collado, MS
    Mantovani, VE
    Goicoechea, HC
    Olivieri, AC
    [J]. TALANTA, 2000, 52 (05) : 909 - 920
  • [7] COSTANZI S, 2000, 1 INT C POL MOD DEGR
  • [8] Faber K, 1997, J CHEMOMETR, V11, P181, DOI 10.1002/(SICI)1099-128X(199705)11:3<181::AID-CEM459>3.0.CO
  • [9] 2-7
  • [10] Exact presentation of multivariate calibration model as univariate calibration graph
    Faber, NM
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) : 107 - 114