Square Wave Voltammetric Determination of Fomesafen Herbicide Using Modified Nanostructure Carbon Paste Electrode as a Sensor and Application to Food Samples

被引:18
作者
Demir, Ersin [1 ,2 ]
Inam, Recai [2 ]
机构
[1] Okan Univ, Vocat Sch Hlth Serv, Dept Perfus Tech, TR-34959 Istanbul, Turkey
[2] Gazi Univ, Dept Chem, Fac Sci, TR-06500 Ankara, Turkey
关键词
Fomesafen; Herbicide; Voltammetry; Determination; SELECTIVE POTENTIOMETRIC SENSOR; POLY(VINYL CHLORIDE) MATRIX; POLAROGRAPHIC-DETERMINATION; STRIPPING VOLTAMMETRY; SWEEP VOLTAMMETRY; RIVER WATER; PVC MATRIX; MEMBRANE; ION; MERCURY(II);
D O I
10.1007/s12161-016-0551-1
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Cyclic and square wave voltammetric measurements were performed to deduce the electrochemical behavior of fomesafen herbicide on the prepared carbon nanotube paste electrodes. Fomesafen has created a well-defined cathodic peak at -540 mV (vs. Ag/AgCl), but no corresponding oxidation peak has appeared on the reverse scan. The influence of the pH on the electro-reduction peak was tested at various pH values, and the E (p) versus pH plot suggested that protons are involved in reduction process. Electrochemical studies showed that -NO2 group was responsible for the reduction process. A linear relationship has been constructed in the concentration range of 0.30-40 mg/L. The limits of detection and quantification values were obtained as 0.089 and 0.297 mg/L, respectively. Fomesafen was determined in the presence of some well-known pesticides, and the extent of recoveries of 5 mg/L fomesafen in the presence of equal amounts of pesticides anilazine, pymetrozine, and triflumizole was 103.7 +/- 0.9, 94.3 +/- 0.4, and 97.9 +/- 0.5 %, respectively (n = 3). The accuracy of the recommended method was further proved by the determination of fomesafen in spiked real samples such as apricot juice, cherry juice, and lake water with a relative error of -4.2, -2.8, and -1.8 %, respectively. The obtained results suggest that the recommended method is sufficiently accurate, selective, and precise.
引用
收藏
页码:74 / 82
页数:9
相关论文
共 46 条
[1]   Voltammetric determination of the herbicide Bifenox in drinking and river water using a silver solid amalgam electrode [J].
Barek, Jiri ;
Cabalkova, Dana ;
Fischer, Jan ;
Navratil, Tomas ;
Peckova, Karolina ;
Yosypchuk, Bogdan .
ENVIRONMENTAL CHEMISTRY LETTERS, 2011, 9 (01) :83-86
[2]   Fe3+ - Ion Selective Electrode Developed as a Detector in Flow Injection Analysis [J].
Demir, Ersin ;
Kemer, Baris ;
Isildak, Ibrahim ;
Aboul-Enein, Hassan Y. .
CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) :104-108
[3]   Fullerene-C60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone -: An anabolic steroid used in doping [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Bachheti, Neeta .
ANALYTICA CHIMICA ACTA, 2007, 597 (01) :82-89
[4]   Voltammetric biosensors for the determination of paracetamol at carbon nanotube modified pyrolytic graphite electrode [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Chatterjee, Sanghamitra .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01) :252-258
[5]   Study and determination of the pesticide Imidacloprid by square wave adsorptive stripping voltammetry [J].
Guiberteau, A ;
Galeano, T ;
Mora, N ;
Parrilla, P ;
Salinas, F .
TALANTA, 2001, 53 (05) :943-949
[6]   Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II) [J].
Gupta, V. K. ;
Singh, A. K. ;
Al Khayat, A. ;
Gupta, Barkha .
ANALYTICA CHIMICA ACTA, 2007, 590 (01) :81-90
[7]   Copper(H)e-selective potentiometric sensors based on porphyrins in PVC matrix [J].
Gupta, V. K. ;
Jain, A. K. ;
Maheshwari, G. ;
Lang, Heinrich ;
Ishtaiwi, Z. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 117 (01) :99-106
[8]   Anion recognition using newly synthesized hydrogen bonding disubstituted phenylhydrazone-based receptors: Poly(vinyl chloride)-based sensor for acetate [J].
Gupta, Vinod K. ;
Goyal, Rajendra N. ;
Sharma, Ram A. .
TALANTA, 2008, 76 (04) :859-864
[9]   Aluminum(III) selective potentiometric sensor based on morin in poly(vinyl chloride) matrix [J].
Gupta, Vinod K. ;
Jain, Ajay K. ;
Maheshwari, Gaurav .
TALANTA, 2007, 72 (04) :1469-1473
[10]   Electrochemical Analysis of Some Toxic Metals by Ion-Selective Electrodes [J].
Gupta, Vinod K. ;
Ganjali, M. R. ;
Norouzi, P. ;
Khani, H. ;
Nayak, Arunima ;
Agarwal, Shilpi .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2011, 41 (04) :282-313