Curing depth of composite resin light cured by LED and halogen light-curing units

被引:12
|
作者
Calixto, L. R. [1 ]
Lima, D. M. [1 ]
Queiroz, R. S. [1 ]
Rastelli, A. N. S. [2 ]
Bagnato, V. S. [2 ]
Andrade, M. F. [1 ]
机构
[1] UNESP, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil
[2] USP, Phys Inst Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
关键词
47; 54; Fj; 62; 20; Qp; 68; 35; Gy;
D O I
10.1134/S1054660X08110303
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.
引用
收藏
页码:1365 / 1369
页数:5
相关论文
共 50 条
  • [1] Depth of cure of composite resin with two light-curing units
    Dannheimer, MFG
    Marais, JT
    Germishuys, PJ
    Borman, JW
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1205 - 1205
  • [2] Changes in the temperature of a dental light-cured composite resin by different light-curing units
    Rastelli, A. N. S.
    Jacomassi, D. P.
    Bagnato, V. S.
    LASER PHYSICS, 2008, 18 (08) : 1003 - 1007
  • [3] Comparison of curing depth of a colored polyacid-modified composite resin with different light-curing units
    Vandenbulcke, Jeroen D. E.
    Marks, Luc A. M.
    Martens, Luc C.
    Verbeeck, Ronald M. H.
    QUINTESSENCE INTERNATIONAL, 2010, 41 (09): : 787 - 794
  • [4] Influence of the light-curing units on the depth of cure of two shades of composite resin.
    Veronezi, MC
    Curvelo, VP
    Bastos, MTAA
    Legramandi, DB
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 685 - 685
  • [5] CURING DEPTH OF VISIBLE-LIGHT CURED COMPOSITE RESIN
    SKEETERS, TM
    TIMMONS, JH
    MITCHELL, RJ
    JOURNAL OF DENTAL RESEARCH, 1983, 62 : 219 - 219
  • [6] The influence of resin composite type on depth of cure with LED and QTH light-curing devices.
    Ernst, C. -P.
    Meyer, G. R.
    Volmerhaus, J.
    Ahlers, M. O.
    Willershausen, B.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B199 - B199
  • [7] The polymerization shrinkage of light-cured composite resin with different light-curing modes.
    Tseng, W. Y.
    Chen, M. -H.
    Wang, J. -L.
    Chen, R. -S.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B262 - B262
  • [8] Photomitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units
    Uhl, A
    Mills, RW
    Jandt, KD
    BIOMATERIALS, 2003, 24 (10) : 1787 - 1795
  • [9] Effectiveness of light-curing units
    Burke, FJT
    Earp, DP
    Farrell, S
    BRITISH DENTAL JOURNAL, 1996, 181 (08) : 283 - 283
  • [10] LIGHT-CURING RESIN SYSTEMS
    POLLACK, BF
    LEWIS, AL
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1983, 107 (03): : 386 - &