Ultrasound Measures of the Lumbar Multifidus: Effect of Task and Transducer Position on Reliability

被引:24
作者
Lariviere, Christian [1 ,2 ]
Gagnon, Dany [2 ,3 ]
De Oliveira, Eros, Jr. [2 ,3 ]
Henry, Sharon M. [4 ]
Mecheri, Hakim [1 ,2 ]
Dumas, Jean-Pierre [5 ]
机构
[1] Occupat Hlth & Safety Res Inst Robert Sauve IRSST, Montreal, PQ H3A 3C2, Canada
[2] Site Inst Readaptat Gingras Lindsay de Montreal I, Ctr Interdisciplinary Res Rehabil Greater Montrea, Montreal, PQ, Canada
[3] Univ Montreal, Sch Rehabil, Montreal, PQ, Canada
[4] Univ Vermont, Burlington, VT USA
[5] Univ Sherbrooke, Sch Rehabil, Sherbrooke, PQ J1K 2R1, Canada
关键词
LOW-BACK-PAIN; TRANSVERSUS ABDOMINIS; TRUNK MUSCLES; PHYSICAL-ACTIVITY; MEASUREMENT ERROR; THICKNESS; SIZE; QUESTIONNAIRE; SPINE;
D O I
10.1016/j.pmrj.2013.03.010
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To (1) assess the intra- and inter-rater reliability of different ultrasound (US) measures of the lumbar multifidus muscle in subjects with and without chronic low back pain and (2) test 3 different ways to enhance reliability, that is, by testing different tasks, using a template, and averaging trials within or between days. Design: Cross-sectional repeated-measures design. Setting: Laboratory setting. Patients: Fifteen subjects with chronic low back pain and 15 control subjects. Methods: Subjects (n = 30) performed contralateral arm lifting and contralateral leg lifting while in the prone position. Two 7-second videos of the lumbar multifidus (from rest to contraction) were collected with and without a template (transparency) to reposition the transducer on the skin. One of the two raters repeated the testing 7 to 14 days later to assess intrarater reliability in addition to inter-rater reliability. Reliability was assessed with the generalizability theory as a framework. Main outcome measurements: US imaging measures of the lumbar multifidus thickness were obtained in patients at rest and during standardized contractions (hereafter called primary measures) at 2 vertebral levels and on both sides. These primary measures were used to calculate different, potentially useful US parameters (hereafter called derived measures). Results: Intrarater reliability was better than inter-rater reliability, and primary measures were more reliable than derived measures. The tasks investigated showed comparable reliability results, and the use of the transducer position template was not effective to increase reliability. Averaging the measures of 3 images increased reliability substantially. Conclusions: Optimal reliability requires the use of a single rater and the averaging of at least 3 images per visit. In these conditions, primary measures reach acceptable levels of reliability, which was more difficult to achieve for most derived measures. Arm or leg lifting tasks showed similar reliability, and thus the arm-lifting task is recommended for comparisons with previous studies. The use of a transducer position template is not recommended.
引用
收藏
页码:678 / 687
页数:10
相关论文
共 28 条
  • [1] BAECKE JAH, 1982, AM J CLIN NUTR, V36, P936
  • [2] Changes in the cross-sectional area of multifidus and psoas in patients with unilateral back pain - The relationship to pain and disability
    Barker, KL
    Shamley, DR
    Jackson, D
    [J]. SPINE, 2004, 29 (22) : E515 - E519
  • [3] Reproducibility of Rehabilitative Ultrasound Imaging for the Measurement of Abdominal Muscle Activity: A Systematic Review
    Costa, Leonardo Oliveira Pena
    Maher, Chris G.
    Latimer, Jane
    Smeets, Rob J. E. M.
    [J]. PHYSICAL THERAPY, 2009, 89 (08): : 756 - 769
  • [4] Reliability of EMG measurements for trunk muscles during maximal and sub-maximal voluntary isometric contractions in healthy controls and CLBP patients
    Dankaerts, W
    O'Sullivan, PB
    Burnett, AF
    Straker, LM
    Danneels, LA
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (03) : 333 - 342
  • [5] BODY FAT ASSESSED FROM TOTAL-BODY DENSITY AND ITS ESTIMATION FROM SKINFOLD THICKNESS - MEASUREMENTS ON 481 MEN AND WOMEN AGED FROM 16 TO 72 YEARS
    DURNIN, JVGA
    WOMERSLEY, J
    [J]. BRITISH JOURNAL OF NUTRITION, 1974, 32 (01) : 77 - 97
  • [6] Changes in recruitment of the abdominal muscles in people with low back pain - Ultrasound measurement of muscle activity
    Ferreira, PH
    Ferreira, ML
    Hodges, PW
    [J]. SPINE, 2004, 29 (22) : 2560 - 2566
  • [7] Fleiss R.L., 1986, The design and analysis of clinical experiments, DOI DOI 10.1002/9781118032923.CH1
  • [8] A Systematic Review of the Reliability of Rehabilitative Ultrasound Imaging for the Quantitative Assessment of the Abdominal and Lumbar Trunk Muscles
    Hebert, Jeffrey J.
    Koppenhaver, Shane L.
    Parent, Eric C.
    Fritz, Julie M.
    [J]. SPINE, 2009, 34 (23) : E848 - E856
  • [9] EVIDENCE OF LUMBAR MULTIFIDUS MUSCLE WASTING IPSILATERAL TO SYMPTOMS IN PATIENTS WITH ACUTE SUBACUTE LOW-BACK-PAIN
    HIDES, JA
    STOKES, MJ
    SAIDE, M
    JULL, GA
    COOPER, DH
    [J]. SPINE, 1994, 19 (02) : 165 - 172
  • [10] Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging
    Kiesel, Kyle B.
    Uhl, Tim L.
    Underwood, Frank B.
    Rodd, Donald W.
    Nitz, Arthur J.
    [J]. MANUAL THERAPY, 2007, 12 (02) : 161 - 166