Post-cracking behavior of hybrid fiber-reinforced concrete-filled steel tube beams

被引:28
作者
Guler, Soner [1 ]
Yavuz, Demet [2 ]
机构
[1] Univ Van Yuzuncu lid, Dept Civil Engn, Fac Engn, TR-65080 Van, Turkey
[2] Univ Ege, Fac Engn, Dept Civil Engn, Izmir, Turkey
关键词
Flexural behavior; Carbon steel; Stainless steel; Aluminum tube; Performance indices; FLEXURAL BEHAVIOR; MECHANICAL-PROPERTIES; PERFORMANCE; STRENGTH; COLUMN; TOUGHNESS; MACRO;
D O I
10.1016/j.conbuildmat.2019.01.192
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The main purpose of this study was to examine the moment, ductility and toughness capacities of steel and hybrid (steel + synthetic) fiber-reinforced concrete (FRC)-filled square aluminum (AL), carbon steel (CS) and stainless steel (SS) tube beams subjected to four-point-in-plane bending. A total of 9 hollow, 18 plain and 72 steel and hybrid FRC-filled AL, CS, and SS beams were tested under four-pointbending until failure. The effects of the steel tube thickness (2, 3 and 4 mm), fiber type (steel and hybrid), fiber volume ratio (0.5% and 1.5%), and the compressive strength of concrete (30 and 70 MPa) on the moment, ductility and flexural toughness capacity of low- and high-strength steel and hybrid FRC-filled AL, CS and SS beams were examined. The results showed that while the steel and hybrid fibers considerably increased the ductility and toughness capacities of the AL, CS and SS beams, they did not significantly contribute to their moment capacities. When compared to plain concrete filled AL, CS and SS beams, although the greatest increase in the moment capacities of the 1.5% steel and hybrid FRC-filled AL, CS and SS beams were only 7.65%, 2.88%, 2.28% and 9.12%, 3.68%, 12.1%, respectively for 70 MPa compressive strength of concrete, the increase in ductility capacities of these beams were 26.6%, 64.3%, 95.2% and 29.9%, 85.9%, 98.9%, respectively. Furthermore, the increase in pre-peak and post-peak energy absorption capacities of 1.5% steel and hybrid FRC-filled AL CS, and SS beams were obtained as 7.86%, 3.26%, 6.30% and 26.57%, 38.38%, 53.44%, respectively for 70 MPa compressive strength of concrete. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:285 / 305
页数:21
相关论文
共 47 条
  • [1] A review on the assessment and prediction of the orientation and distribution of fibres for concrete
    Alberti, M. G.
    Enfedaque, A.
    Galvez, J. C.
    [J]. COMPOSITES PART B-ENGINEERING, 2018, 151 : 274 - 290
  • [2] Effects of steel fiber addition on mechanical properties of concrete and RC beams
    Altun, Fatih
    Haktanir, Tefaruk
    Ari, Kamura
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (03) : 654 - 661
  • [3] [Anonymous], 2004, 199314 EN
  • [4] [Anonymous], 2010, 2281 GBT
  • [5] [Anonymous], 2002, 2061 TS EN
  • [6] [Anonymous], 2009, 123905 TS EN
  • [7] [Anonymous], 2010, 123903 TS EN
  • [8] [Anonymous], 2004, 199313 EN
  • [9] [Anonymous], 2000, 199911 EN
  • [10] Arivalagan K., 2009, J ENG SCI TECHNOL RE, V2, P145