Seismic performance of a novel interior precast concrete beam-column joint using ultra-high performance concrete

被引:64
|
作者
Zhang, Zi-Yu [1 ]
Ding, Ran [2 ]
Nie, Xin [2 ]
Fan, Jian-Sheng [2 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Dept Civil Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Ultra high performance concrete (UHPC); Precast concrete beam-column joints; Seismic performance; Non-steam-cured; Headed bars; Anchorage length; Stirrup ratio; ENGINEERED CEMENTITIOUS COMPOSITES; SHEAR PERFORMANCE; BEHAVIOR; BOND;
D O I
10.1016/j.engstruct.2020.111145
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In traditional precast reinforced concrete (RC) frame structures, the reinforcement details are usually complex in the joint zone, which makes the fabrication process difficult and thus affects the construction quality and speed. Ultra-high performance concrete (UHPC) exhibits substantially higher shear resistance and bond strength than normal concrete due to its much larger compressive and tensile strengths. As a result, the application of UHPC can significantly help reducing the amount of stirrups and anchorage length of the longitudinal bar in the joint zone of precast RC frames, which can obviously simplify the joint construction. This paper presents the cyclic tests of four interior precast UHPC/RC composite beam-column joints to evaluate quantitatively the effect of replacing the normal concrete by UHPC in the joint zone. Considering that the condition of steam curing is difficult to achieve in the actual construction environment, the non-steam-cured UHPC was adopted and proved to exhibit adequate compressive (> 120 MPa) and tensile strength (> 7 MPa) with the ultimate tensile strain larger than 1%. The main variables in this study are the anchorage methods, anchorage lengths and stirrup ratios in the joint zone. The cyclic load tests demonstrate that the cast-in-situ UHPC can work well with the precast concrete and there is no need of stirrups in the UHPC joint zone. With the use of UHPC instead of normal concrete, the anchorage length of the beam straight and headed bars can be decreased to 16d(b) and 8.1d(b), respectively. Therefore, the application of UHPC in the joint zone is practicable and can greatly ease the fabrication process, especially with the use of headed bars.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Experimental Investigation of Seismic Performance of a Hybrid Beam-Column Connection in a Precast Concrete Frame
    Chen, Weihong
    Xie, Yujun
    Guo, Xiaohui
    Li, Dong
    BUILDINGS, 2022, 12 (06)
  • [22] Seismic performance of a novel precast concrete beam-column connection using low-shrinkage engineered cementitious composites
    Gou, Shuangke
    Ding, Ran
    Fan, Jiansheng
    Nie, Xin
    Zhang, Jun
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 192 : 643 - 656
  • [23] Study of seismic performance and resilience of a precast concrete beam-column joint with a replaceable energy-dissipation component
    Ge, Qi
    Ai, Jingsong
    Mao, Yu
    Zhou, Decai
    Li, Youjie
    Lu, Yang
    Xiong, Feng
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [24] Experimental study on seismic behavior of precast reinforced concrete beam-column joint
    Gao, Xiangling
    Xu, Longbiao
    Zhang, Yuanda
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 235 - 241
  • [25] Experimental study on seismic performance of ultra-high performance concrete connected precast columns
    Deng M.-K.
    Jin M.-N.
    Guo L.-Y.
    Ma F.-D.
    Liu H.-Z.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2022, 56 (10): : 1995 - 2006
  • [26] Seismic performance evaluation of precast post-tensioned high-performance concrete frame beam-column joint under cyclic loading
    Pang, Xuefei
    Li, Yangchun
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [27] Experimental study on seismic performance of damaged steel concrete special-shaped beam-column joints reinforced by manually compacted ultra-high performance concrete
    Hu, Aoxiang
    Du, Jing
    Song, Xiaofang
    Liao, Xi
    STEEL AND COMPOSITE STRUCTURES, 2024, 53 (04): : 421 - 434
  • [28] Experimental study on internal precast beam-column ultra-high-performance concrete connection and shear capacity of its joint
    Ma, Fudong
    Deng, Mingke
    Yang, Yong
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [29] Seismic performance of reinforced concrete beam-column joint strengthening by frp sheets
    Attari, Nassereddine
    Youcef, Youcef Si
    Amziane, Sofiane
    STRUCTURES, 2019, 20 : 353 - 364
  • [30] Seismic performance of exterior reinforced concrete beam-column joint with corroded reinforcement
    Zhang, Xinchen
    Li, Bing
    ENGINEERING STRUCTURES, 2021, 228