The biomechanical evaluation of four fixation techniques for proximal biceps tenodesis

被引:254
作者
Mazzocca, AD
Bicos, J
Santangelo, S
Romeo, AA
Arciero, RA
机构
[1] Univ Connecticut, Ctr Hlth, Dept Orthopaed Surg, Farmington, CT USA
[2] Rush Presbyterian St Lukes Med Ctr, Dept Orthopaed Surg, Shoulder Sect, Chicago, IL 60612 USA
关键词
biceps tenodesis; interference screw; subpectoral;
D O I
10.1016/j.arthro.2005.08.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to compare the cyclic displacement and ultimate failure strength of 4 proximal biceps tendon tenodesis fixation methods: the open subpectoral bone tunnel (SBT) biceps tenodesis, the arthroscopic suture anchor (SA) tenodesis, the open subpectoral interference screw (SIS) fixation technique, and the arthroscopic interference screw (AIS) technique. Type of Study: Biomechanical experimental control. Methods: Twenty fresh-frozen cadaver shoulders were dissected free of soft tissues, leaving the proximal humerus and the proximal biceps tendon as a free graft. Specimens were randomized to I of 4 groups with 5 total specimens in each group. A proximal biceps tenodesis was performed according to the techniques listed above. The specimens were mounted for an axial pull of the biceps tendon on a servohydraulic materials testing system with a 100-N load cycled at 1 Hz for 5,000 cycles, followed by an axial load to failure test. Cyclic displacement, ultimate load to failure, and site of failure were recorded for each specimen. Results: The mean cyclic displacement recorded for each experimental group was as follows: SBT group, 9.39 +/- 2.82 mm; AIS group, 5.26 +/- 2.60 mm; SIS group, 1.53 +/- 0.60 mm; and SA group, 3.87 +/- 2.11 mm. The mean ultimate failure loads after 5,000 cycles were as follows: SBT group, 242.4 +/- 51.33 N; AIS group, 237.6 +/- 27.58 N; SIS group, 252.4 +/- 68.63 N; and SA group, 164.8 +/- 37.47 N. Each specimen failed at the tenodesis site. Conclusions: The SBT group showed statistically significant greater displacement than the other tenodesis methods. There were no statistically significant differences in ultimate failure strength between any of the biceps tenodesis methods tested. Clinical Relevance: The data serve as a guide to the surgeon performing a proximal biceps tenodesis in choosing a fixation method.
引用
收藏
页码:1296 / 1306
页数:11
相关论文
共 24 条
[1]  
Abbott LC, 1939, SURGERY, V6, P817
[2]   Arthroscopic biceps tenodesis [J].
Ahmad, CS ;
ElAttrache, NS .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2003, 34 (04) :499-+
[3]  
[Anonymous], CLIN ORTHOP RELAT R
[4]  
[Anonymous], 1944, NY State J Med
[5]   INTEGRATED ACTIONS AND FUNCTIONS OF THE CHIEF FLEXORS OF THE ELBOW - A DETAILED ELECTROMYOGRAPHIC ANALYSIS [J].
BASMAJIAN, JV ;
LATIF, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1957, 39 (05) :1106-1118
[6]   Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation [J].
Boileau, P ;
Krishnan, SG ;
Coste, JS ;
Walch, G .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09) :1002-1012
[7]  
DEPALMA A F, 1954, Clin Orthop, V3, P69
[8]  
Edwards TB, 2003, TECH SHOULDER ELBOW, V4, P195
[9]  
FROIMSON AI, 1975, CLIN ORTHOP RELAT R, P245
[10]   Arthroscopic biceps tenodesis: Operative technique [J].
Gartsman, GM ;
Hammerman, SM .
ARTHROSCOPY, 2000, 16 (05) :550-552