Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise

被引:29
作者
Jakovljevic, Djordje G. [1 ,2 ,3 ]
Moore, Sarah [2 ,4 ]
Hallsworth, Kate [2 ,4 ]
Fattakhova, Gulnar [2 ]
Thoma, Christian [2 ,4 ]
Trenell, Michael I. [2 ,4 ]
机构
[1] Newcastle Univ, Sch Med, MoveLab, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Newcastle Univ, MRC Ctr Brain Ageing & Vital, MoveLab Phys Activ & Exercise Res, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[3] Newcastle Univ, Sch Med, Inst Ageing & Hlth, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[4] Newcastle Univ, Inst Cellular Med, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
基金
英国医学研究理事会;
关键词
Cardiac output; Exercise testing; Bioimpedance; Bioreactance; PULMONARY-ARTERY CATHETERS; MAXIMAL AEROBIC EXERCISE; IMPEDANCE CARDIOGRAPHY; CONTROLLED-TRIAL; HEART-FAILURE; STROKE VOLUME; RELIABILITY; PRESSURE; VALIDITY; SYSTEM;
D O I
10.1007/s10877-012-9334-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance methods and those estimated from measured oxygen consumption, (2) determined the relationship between cardiac output and oxygen consumption, and (3) assessed the agreement between the bioreactance and bioimpedance methods. Twelve healthy subjects (aged 30 +/- A 4 years) performed graded cardiopulmonary exercise test on a recumbent cycle ergometer on two occasions, 1 week apart. Cardiac output was monitored at rest, at 30, 50, 70, 90, 150 W and at peak exercise intensity by bioreactance and bioimpedance and expired gases collected. Resting cardiac output was not significantly different between the bioreactance and bioimpedance methods (6.2 +/- A 1.4 vs. 6.5 +/- A 1.4 l min(-1), P = 0.42). During exercise cardiac outputs were correlated with oxygen uptake for both bioreactance (r = 0.84, P < 0.01) and bioimpedance techniques (r = 0.82, P < 0.01). At peak exercise bioimpedance estimated significantly lower cardiac outputs than both bioreactance and theoretically calculated cardiac output (14.3 +/- A 2.6 vs. 17.5 +/- A 5.2 vs. 16.9 +/- A 4.9 l min(-1), P < 0.05). Bland-Altman analyses including data from rest and exercise demonstrated that the bioimpedance method reported similar to 1.5 l min(-1) lower cardiac output than bioreactance with lower and upper limits of agreement of -2.98 to 5.98 l min(-1). Bioimpedance and bioreactance methods provide different cardiac output estimates, particularly at high exercise intensity, and therefore the two methods cannot be used interchangeably. In contrast with bioimpedance, bioreactance cardiac outputs are similar to those estimated from measured oxygen consumption.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [41] COMPARISON OF BIOIMPEDANCE AND DOPPLER ULTRASOUND CARDIAC-OUTPUT IN CAPD PATIENTS
    NG, HWK
    WALLEYL, TJ
    TSAO, Y
    FAHAL, IH
    AHMAD, R
    BRECKENRIDGE, AM
    METHODS AND FINDINGS IN EXPERIMENTAL AND CLINICAL PHARMACOLOGY, 1995, 17 (01): : 59 - 65
  • [42] HAEMODYNAMIC CHANGES DURING CRANIOTOMY MONITORED BY A BIOIMPEDANCE PLETHYSMOGRAPHIC NONINVASIVE CARDIAC OUTPUT MONITOR
    Ali, Zulfiqar
    Rao, Umamaheswara
    Jaganath, A.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2009, 23 (03) : 157 - 161
  • [43] A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method
    Anne Charloux
    Evelyne Lonsdorfer-Wolf
    Ruddy Richard
    Eliane Lampert
    Monique Oswald-Mammosser
    Bertrand Mettauer
    Bernard Geny
    Jean Lonsdorfer
    European Journal of Applied Physiology, 2000, 82 : 313 - 320
  • [44] Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography
    Alicia Gonzalez-Represas
    Laurent Mourot
    The International Journal of Cardiovascular Imaging, 2020, 36 : 447 - 455
  • [45] Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography
    Gonzalez-Represas, Alicia
    Mourot, Laurent
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (03) : 447 - 455
  • [46] QUANTITATIVE RADIOCARDIOGRAPHIC EVALUATION OF CARDIAC DYNAMICS IN MAN AT REST AND DURING EXERCISE
    KUIKKA, J
    TIMISJARVI, J
    TUOMINEN, M
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1979, 39 (05) : 423 - 434
  • [47] Noninvasive Cardiac Output Measurement at Rest and During Exercise in Pediatric Patients After Interventional or Surgical Atrial Septal Defect Closure
    Wiegand, Gesa
    Binder, Wolfhard
    Ulmer, Heidi
    Kaulitz, Renate
    Riethmueller, Joachim
    Hofbeck, Michael
    PEDIATRIC CARDIOLOGY, 2012, 33 (07) : 1109 - 1114
  • [48] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY A CARBON-DIOXIDE REBREATHING METHOD AT REST AND DURING EXERCISE
    NUGENT, AM
    MCPARLAND, J
    MCENEANEY, DJ
    STEELE, I
    CAMPBELL, NPS
    STANFORD, CF
    NICHOLLS, DP
    EUROPEAN HEART JOURNAL, 1994, 15 (03) : 361 - 368
  • [49] Agreement of Cardiac Output Measurements between Bioreactance and Transthoracic Echocardiography in Preterm Infants during the Transitional Phase: A Single-Centre, Prospective Study
    Van Wyk, Lizelle
    Smith, Johan
    Lawrenson, John
    De Boode, Willem Pieter
    NEONATOLOGY, 2020, 117 (03) : 271 - 278
  • [50] INFLUENCE OF THE VENTILATORY CYCLE ON CARDIAC-OUTPUT DETERMINATION DURING MECHANICAL VENTILATION - COMPARISON OF NONINVASIVE ELECTRICAL BIOIMPEDANCE TO THE STANDARD THERMODILUTION METHOD
    CASTOR, G
    HELMS, J
    NIEDERMARK, I
    MOLTER, G
    MOTSCH, J
    ALTMAYER, P
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (01): : 57 - 61