Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise

被引:29
作者
Jakovljevic, Djordje G. [1 ,2 ,3 ]
Moore, Sarah [2 ,4 ]
Hallsworth, Kate [2 ,4 ]
Fattakhova, Gulnar [2 ]
Thoma, Christian [2 ,4 ]
Trenell, Michael I. [2 ,4 ]
机构
[1] Newcastle Univ, Sch Med, MoveLab, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Newcastle Univ, MRC Ctr Brain Ageing & Vital, MoveLab Phys Activ & Exercise Res, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[3] Newcastle Univ, Sch Med, Inst Ageing & Hlth, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[4] Newcastle Univ, Inst Cellular Med, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
基金
英国医学研究理事会;
关键词
Cardiac output; Exercise testing; Bioimpedance; Bioreactance; PULMONARY-ARTERY CATHETERS; MAXIMAL AEROBIC EXERCISE; IMPEDANCE CARDIOGRAPHY; CONTROLLED-TRIAL; HEART-FAILURE; STROKE VOLUME; RELIABILITY; PRESSURE; VALIDITY; SYSTEM;
D O I
10.1007/s10877-012-9334-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance methods and those estimated from measured oxygen consumption, (2) determined the relationship between cardiac output and oxygen consumption, and (3) assessed the agreement between the bioreactance and bioimpedance methods. Twelve healthy subjects (aged 30 +/- A 4 years) performed graded cardiopulmonary exercise test on a recumbent cycle ergometer on two occasions, 1 week apart. Cardiac output was monitored at rest, at 30, 50, 70, 90, 150 W and at peak exercise intensity by bioreactance and bioimpedance and expired gases collected. Resting cardiac output was not significantly different between the bioreactance and bioimpedance methods (6.2 +/- A 1.4 vs. 6.5 +/- A 1.4 l min(-1), P = 0.42). During exercise cardiac outputs were correlated with oxygen uptake for both bioreactance (r = 0.84, P < 0.01) and bioimpedance techniques (r = 0.82, P < 0.01). At peak exercise bioimpedance estimated significantly lower cardiac outputs than both bioreactance and theoretically calculated cardiac output (14.3 +/- A 2.6 vs. 17.5 +/- A 5.2 vs. 16.9 +/- A 4.9 l min(-1), P < 0.05). Bland-Altman analyses including data from rest and exercise demonstrated that the bioimpedance method reported similar to 1.5 l min(-1) lower cardiac output than bioreactance with lower and upper limits of agreement of -2.98 to 5.98 l min(-1). Bioimpedance and bioreactance methods provide different cardiac output estimates, particularly at high exercise intensity, and therefore the two methods cannot be used interchangeably. In contrast with bioimpedance, bioreactance cardiac outputs are similar to those estimated from measured oxygen consumption.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [31] VO2 AND CARDIAC-OUTPUT DURING REST-EXERCISE AND EXERCISE-EXERCISE TRANSIENTS
    LEYK, D
    HOFFMANN, U
    ESSFELD, D
    BAUM, K
    STEGEMANN, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 : 61 - 65
  • [32] Comparison of bioimpedance and oesophageal Doppler cardiac output monitoring during abdominal aortic surgery
    HK Jørgensen
    J Bisgaard
    T Gilsaa
    Critical Care, 16 (Suppl 1):
  • [33] Bioreactance Is Not Interchangeable with Thermodilution for Measuring Cardiac Output during Adult Liver Transplantation
    Han, Sangbin
    Lee, Jong Hwan
    Kim, Gaabsoo
    Ko, Justin Sangwook
    Choi, Soo Joo
    Kwon, Ji Hae
    Heo, Burn Young
    Gwak, Mi Sook
    PLOS ONE, 2015, 10 (05):
  • [34] Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization
    Barin, E
    Haryadi, DG
    Schookin, SI
    Westenskow, DR
    Zubenko, VG
    Beliaev, KR
    Morozov, AA
    CRITICAL CARE MEDICINE, 2000, 28 (03) : 698 - 702
  • [35] Cardiac output changes during exercise in heart failure patients: focus on mid-exercise
    Corrieri, Nicoletta
    Del Torto, Alberico
    Vignati, Carlo
    Maragna, Riccardo
    De Martino, Fabiana
    Cellamare, Martina
    Farina, Stefania
    Salvioni, Elisabetta
    Bonomi, Alice
    Agostoni, Piergiuseppe
    ESC HEART FAILURE, 2021, 8 (01): : 55 - 62
  • [36] A comparison of methods of measuring cardiac output during cardiac catheterization in an elderly population
    Vaitkus, PT
    Higgins, JC
    CARDIOLOGY IN THE ELDERLY, 1996, 4 (01): : 39 - 43
  • [37] Test-Retest Reliability of Non-Invasive Cardiac Output Measurement during Exercise in Healthy Volunteers in Daily Clinical Routine
    Barroso, Michael Thomas Coll
    Hoppe, Matthias Wilhelm
    Boehme, Philip
    Krahn, Thomas
    Kiefer, Christian
    Kramer, Frank
    Mondritzki, Thomas
    Pirez, Phillipe
    Dinh, Wilfried
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2019, 113 (02) : 231 - 239
  • [38] Continuous non-invasive cardiac output monitoring during exercise: validation of electrical cardiometry with Fick and thermodilution methods
    Liu, Y. H.
    Dhakal, B. P.
    Keesakul, C.
    Kacmarek, R. M.
    Lewis, G. D.
    Jiang, Y.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (01) : 129 - 131
  • [39] Measuring Cardiac Output during Cardiopulmonary Exercise Testing
    Vignati, Carlo
    Cattadori, Gaia
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2017, 14 : S48 - S52
  • [40] Haemodynamic Changes During Craniotomy Monitored By A Bioimpedance Plethysmographic Noninvasive Cardiac Output Monitor
    Zulfiqar Ali
    G. S. Umamaheswara Rao
    A. Jaganath
    Journal of Clinical Monitoring and Computing, 2009, 23 : 157 - 161