Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise

被引:29
作者
Jakovljevic, Djordje G. [1 ,2 ,3 ]
Moore, Sarah [2 ,4 ]
Hallsworth, Kate [2 ,4 ]
Fattakhova, Gulnar [2 ]
Thoma, Christian [2 ,4 ]
Trenell, Michael I. [2 ,4 ]
机构
[1] Newcastle Univ, Sch Med, MoveLab, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Newcastle Univ, MRC Ctr Brain Ageing & Vital, MoveLab Phys Activ & Exercise Res, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[3] Newcastle Univ, Sch Med, Inst Ageing & Hlth, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[4] Newcastle Univ, Inst Cellular Med, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
基金
英国医学研究理事会;
关键词
Cardiac output; Exercise testing; Bioimpedance; Bioreactance; PULMONARY-ARTERY CATHETERS; MAXIMAL AEROBIC EXERCISE; IMPEDANCE CARDIOGRAPHY; CONTROLLED-TRIAL; HEART-FAILURE; STROKE VOLUME; RELIABILITY; PRESSURE; VALIDITY; SYSTEM;
D O I
10.1007/s10877-012-9334-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance methods and those estimated from measured oxygen consumption, (2) determined the relationship between cardiac output and oxygen consumption, and (3) assessed the agreement between the bioreactance and bioimpedance methods. Twelve healthy subjects (aged 30 +/- A 4 years) performed graded cardiopulmonary exercise test on a recumbent cycle ergometer on two occasions, 1 week apart. Cardiac output was monitored at rest, at 30, 50, 70, 90, 150 W and at peak exercise intensity by bioreactance and bioimpedance and expired gases collected. Resting cardiac output was not significantly different between the bioreactance and bioimpedance methods (6.2 +/- A 1.4 vs. 6.5 +/- A 1.4 l min(-1), P = 0.42). During exercise cardiac outputs were correlated with oxygen uptake for both bioreactance (r = 0.84, P < 0.01) and bioimpedance techniques (r = 0.82, P < 0.01). At peak exercise bioimpedance estimated significantly lower cardiac outputs than both bioreactance and theoretically calculated cardiac output (14.3 +/- A 2.6 vs. 17.5 +/- A 5.2 vs. 16.9 +/- A 4.9 l min(-1), P < 0.05). Bland-Altman analyses including data from rest and exercise demonstrated that the bioimpedance method reported similar to 1.5 l min(-1) lower cardiac output than bioreactance with lower and upper limits of agreement of -2.98 to 5.98 l min(-1). Bioimpedance and bioreactance methods provide different cardiac output estimates, particularly at high exercise intensity, and therefore the two methods cannot be used interchangeably. In contrast with bioimpedance, bioreactance cardiac outputs are similar to those estimated from measured oxygen consumption.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [21] Agreement of Bioreactance Cardiac Output Monitoring With Thermodilution During Hemorrhagic Shock and Resuscitation in Adult Swine
    Berlin, David A.
    Peprah-Mensah, Harrison
    Manoach, Seth
    Heerdt, Paul M.
    CRITICAL CARE MEDICINE, 2017, 45 (02) : E195 - E201
  • [22] Comparison between Modelflow® and echocardiography in the determination of cardiac output during and following pregnancy at rest and during exercise
    Meah, Victoria L.
    Backx, Karianne
    Shave, Rob E.
    Stohr, Eric J.
    Cooper, Stephen-Mark
    JOURNAL OF HUMAN SPORT AND EXERCISE, 2022, 17 (01): : 116 - 135
  • [23] Comparison of ICG thoracic bioimpedance cardiac output monitoring system in patients undergoing cardiac surgery with pulmonary artery cardiac output measurements
    Simon, R.
    Desebbe, O.
    Henaine, R.
    Bastien, O.
    Lehot, J. -J.
    Cannesson, M.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2009, 28 (06): : 537 - 541
  • [24] Does thoracic bioimpedance accurately determine cardiac output in COPD patients during maximal or intermittent exercise?
    Bougault, V
    Lonsdorfer-Wolf, E
    Charloux, A
    Richard, R
    Geny, B
    Oswald-Mammosser, M
    CHEST, 2005, 127 (04) : 1122 - 1131
  • [25] Noninvasive cardiac output monitoring using bioreactance-based technique in pediatric patients with or without ventricular septal defect during anesthesia: in comparison with echocardiography
    Sun, Ying
    Wu, Chi
    Wu, Jun-Zheng
    Wang, Shan-Shan
    Bai, Jie
    Zhu, Ming
    Zhang, Yu-Qi
    Zhang, Ma-Zhong
    PEDIATRIC ANESTHESIA, 2015, 25 (02) : 167 - 173
  • [26] Peak Cardiac Output Determined Using Inert Gas Rebreathing: A Comparison of Two Exercise Protocols
    Bostad, William
    Mccarthy, Devin G.
    Richards, Douglas L.
    Helal, Lucas
    Gibala, Martin J.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (06) : 1014 - 1022
  • [27] Addressing Assumptions for the Use of Non-invasive Cardiac Output Measurement Techniques During Exercise in COPD
    Perrault, Helene
    Richard, Ruddy
    Kapchinsky, Sophia
    Baril, Jacinthe
    Bourbeau, Jean
    Taivassalo, Tanja
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 13 (01) : 75 - 81
  • [28] A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the "direct" Fick method
    Charloux, A
    Lonsdorfer-Wolf, E
    Richard, R
    Lampert, E
    Oswald-Mammosser, M
    Mettauer, B
    Geny, B
    Lonsdorfer, J
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 82 (04) : 313 - 320
  • [29] THE EFFECT OF A MEAL ON CARDIAC-OUTPUT IN MAN AT REST AND DURING MODERATE EXERCISE
    WAALER, BA
    ERIKSEN, M
    JANBU, T
    ACTA PHYSIOLOGICA SCANDINAVICA, 1990, 140 (02): : 167 - 173
  • [30] Measurement of cardiac output during exercise in healthy, trained humans using lithium dilution and pulse contour analysis
    Elliott, Adrian D.
    Skowno, Justin
    Prabhu, Mahesh
    Ansley, Les
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (10) : 1691 - 1701