Study Design. A 1-year-old calf was implanted with titanium pedicle screws either uncoated (n = 7) or coated with hydroxyapatite (n = 7) by the dipping method on the pedicles of vertebrae (t10-I3). Objective. To evaluate biomechanical and histomorphologic responses to titanium pedicle screws uncoated and coated with hydroxyapatite. Summary of Background Data. Failure of fixation caused by loosening of pedicle screws is a problem in spinal surgery. Enhancement of the fixation ability of screws by coating with biocompatible materials may improve prognosis of surgery. Methods. The calf was euthanized 4 months after implantation for determination of insertion and extraction torques for screws, and histologic and scanning electron microscopic examinations of areas screw embedded. Results. Insertion torques did not differ by the kind of screws (99 +/- 5.7 Ncm). However, extraction torques for screws coated with hydroxyapatite were higher than for screws uncoated (249 vs. 133 Ncm, P < 0.01). As compared with uncoated screws, implanted areas for hydroxyapatitecoated screws were denser, had more cracks, and provided better bonding. Fibrous tissue and new bone formation were observed around the areas of uncoated and hydroxyapatitecoated screws embedded, respectively. Conclusions. Hydroxyapatite coating of titanium pedicle screws by the dipping method improved fixation and vertebral bone-implant interface, suggesting a decreased risk of a screw-loosening problem.
引用
收藏
页码:E215 / E220
页数:6
相关论文
共 32 条
[1]  
Aldini NN, 2002, J ORTHOP RES, V20, P1217
[2]  
Barber JW, 1998, J SPINAL DISORD, V11, P215
[3]   Biologic enhancement of spinal fusion [J].
Boden, SD ;
Schimandle, JH .
SPINE, 1995, 20 (24) :S113-S123
[4]   Calcium phosphate coatings deposited by aerosol chemical vapour deposition [J].
Cabañas, MV ;
Vallet-Regí, M .
JOURNAL OF MATERIALS CHEMISTRY, 2003, 13 (05) :1104-1107
[5]   Titanium-alloy enhances bone-pedicle screw fixation:: mechanical and histomorphometrical results of titanium-alloy versus stainless steel [J].
Christensen, FB ;
Dalstra, M ;
Sejling, F ;
Overgaard, S ;
Bünger, C .
EUROPEAN SPINE JOURNAL, 2000, 9 (02) :97-103
[6]   Biocompatibility and osseointegration in osteoporotic bone - A preliminary in vitro and in vivo study [J].
Fini, M ;
Giavaresi, G ;
Torricelli, P ;
Krajewski, A ;
Ravaglioli, A ;
Belmonte, MM ;
Biagini, G ;
Giardino, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :139-143
[7]   Biomaterials for orthopedic surgery in osteoporotic bone: A comparative study in osteopenic rats [J].
Fini, M ;
Aldini, NN ;
Gandolfi, MG ;
Belmonte, MM ;
Giavaresi, G ;
Zucchini, C ;
DeBenedittis, A ;
Amati, S ;
Ravaglioli, A ;
Krayewski, A ;
Rocca, M ;
Guzzardella, GA ;
Biagini, G ;
Giardino, R .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (05) :291-297
[8]   BONDING OF BONE TO APATITE-COATED IMPLANTS [J].
GEESINK, RGT ;
DEGROOT, K ;
KLEIN, CPAT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (01) :17-22
[9]   The effect of hydroxyapatite coating on the bonding of bone to titanium implants in the femora of ovariectomised rats [J].
Hara, T ;
Hayashi, K ;
Nakashima, Y ;
Kanemaru, T ;
Iwamoto, Y .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (04) :705-709
[10]   REMODELING OF BONE AROUND HYDROXYAPATITE AND TITANIUM IN EXPERIMENTAL OSTEOPOROSIS [J].
HAYASHI, K ;
UENOYAMA, K ;
MASHIMA, T ;
SUGIOKA, Y .
BIOMATERIALS, 1994, 15 (01) :11-16