Analysis of Intraocular lens power calculation for eyes with previous myopic LASIK

被引:0
|
作者
Jin, GJC
Crandall, AS
Jin, Y
机构
[1] Eye Inst Utah, Salt Lake City, UT 84107 USA
[2] Univ Utah, Moran Eye Ctr, Salt Lake City, UT USA
[3] Univ Iowa, Dept Ophthalmol, Iowa City, IA 52242 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the effectiveness of a manual keratometry (K) adjusted value for intraocular lens (IOL) power calculation in patients who underwent cataract surgery following previous myopic LASIK. METHODS: Sixteen eyes of 14 consecutive patients who underwent cataract surgery after previous LASIK were evaluated retrospectively. All IOL powers were calculated using an adjusted K value (K minus 1.0 diopter [D]) with the Binkhorst 11 formula aiming for -0.75 to -1.00 D final refraction. Additionally, the IOL power for each eye was retrospectively calculated using K, refractive-derived K, and adjusted K with the Binkhorst 11, Holladay 1, and SRK/T formulas. The final refraction was used as a criterion of accuracy of each approach. RESULTS: Uncorrected visual acuity >= 20/40 was achieved in 14 (87.5%) of 16 eyes. The mean postoperative spherical equivalent refraction was -0.41 +/- 0.57 D (range: +0.50 to -2.00 D). Twelve (75%) of 16 eyes were within +/- 0.50 D of emmetropia and 15 (94%) of 16 eyes were within +/- 1.00 D. No eye was > + 1.00 D. CONCLUSIONS: Using an adjusted K with the Binkhorst 11 formula, aiming for -0.75 to -1.00 D, and with the Holladay I formula, aiming for -0.50 to - 1.00 D, measuring K with a regular manual keratometer permits determination of an IOL power after myopic LASIK without the need of preoperative LASIK refractive data.
引用
收藏
页码:387 / 395
页数:9
相关论文
共 50 条
  • [1] Intraocular lens power calculation for eyes with previous myopic LASIK - Reply
    Lin, George I. C.
    Crandall, Alan S.
    Jin, Yian
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) : 847 - 848
  • [2] Intraocular lens power calculation in high myopic eyes with previous radial keratotomy
    Han, Eui Seok
    Lee, Jin Hak
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 713 - 716
  • [3] Accuracy of recent intraocular lens power calculation methods in post-myopic LASIK eyes
    Gettinger, Kate
    Masui, Sachiko
    Omoto, Miki
    Torii, Hidemasa
    Yotsukura, Erisa
    Nishi, Yasuyo
    Ayaki, Masahiko
    Hayashi, Ken
    Negishi, Kazuno
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Intraocular lens power in myopic eyes
    Savini, Giacomo
    Ducoli, Pietro
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1340 - 1341
  • [5] Intraocular lens power calculation and optimized constants for highly myopic eyes
    Petermeier, Katrin
    Gekeler, Florian
    Messias, Andre
    Spitzer, Martin S.
    Haigis, Wolfgang
    Szurman, Peter
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09): : 1575 - 1581
  • [6] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [7] Accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    EYE AND VISION, 2018, 5
  • [10] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Anders, Philipp
    Anders, Lisa-Marie
    Barbara, Adel
    Szentmary, Nora
    Langenbucher, Achim
    Gatzioufas, Zisis
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14