Biomechanical comparison of polylactide-based versus titanium miniplates in mandible reconstruction in vitro

被引:17
作者
Steffen, C. [1 ,2 ,3 ,4 ]
Sellenschloh, K. [6 ]
Polster, V [6 ]
Heyland, M. [7 ]
Vollmer, M. [6 ]
Morlock, M. M. [6 ]
Heiland, M. [1 ,2 ,3 ,4 ]
Huber, G. [6 ]
Rendenbach, C. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Charite, Dept Oral & Maxillofacial Surg, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Free Univ Berlin, Augustenburger Pl 1, D-13353 Berlin, Germany
[3] Humboldt Univ, Augustenburger Pl 1, D-13353 Berlin, Germany
[4] Berlin Inst Hlth, Augustenburger Pl 1, D-13353 Berlin, Germany
[5] Berlin Inst Hlth BIH, Anna Louisa Karsch Str 2, D-10178 Berlin, Germany
[6] TUHH Hamburg Univ Technol, Inst Biomech, Denickestr 15, D-21703 Hamburg, Germany
[7] Charite, Julius Wolff Inst, Augustenburger Pl 1, D-13353 Berlin, Germany
关键词
Polylactide; Mandible reconstruction; Fibula free flap; Fatigue strength; Biomechanics; Mechanical integrity; MAXILLOFACIAL SURGERY; BIODEGRADABLE PLATES; INTERNAL-FIXATION; STRENGTH; SYSTEMS; DEVICES; SCREWS;
D O I
10.1016/j.jormas.2019.12.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Evaluation of the mechanical integrity and reliability of polylactide-based miniplates for osseous free flap fixation at the mandible in an experimental study setup of a mandible reconstruction model. Material and methods: 1.0 mm titanium miniplates (group TI) (MatrixMandible, DePuy Synthes, Umkirch, Germany) and 1.5 mm polylactide miniplates (group PL) (Inion CPS, Inion Oy, Tampere, Finland) were used to fix a polyurethane (PU) fibula segment to a PU mandible reconstruction model using monocortical non-locking screws. Mastication was simulated via unilateral cyclic dynamic loading at 1 Hz with increasing loads (+ 0.15 N/cycle, Bionix, MTS, USA). A 3D optical tracking system (Aramis, GOM, Braunschweig, Germany) was used to determine interosteotomy movements (IOM). Results: IOM were higher in the polylactide group (distal: P = 0.001, mesial: P = 0.001). Differences in mean stiffness (titanium: 478 + 68 N/mm; polylactide: 425 + 38 N/mm, P = 0.240) and mean force at a vertical displacement of 1.0 mm (titanium: 201.6 + 87.1 N; polylactide: 141.3 + 29.9 N, P= 0.159) were not significant. Conclusions: The results of this study suggest that polylactide-based miniplates provide reduced mechanical integrity and higher interosteotomy movements in comparison to titanium miniplates in vitro. Indications for clinical use of polylactide-based miniplates in mandible reconstruction have to be placed critically. Future studies will focus on clinical complications of polylactide-based plates in risk patients. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:377 / 382
页数:6
相关论文
共 31 条
[1]   Resorbable versus titanium plates for orthognathic surgery [J].
Agnihotry, A. ;
Fedorowicz, Z. ;
Nasser, M. ;
Gill, K. S. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (10)
[2]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[3]   Removal of miniplates in maxillofacial surgery: A follow-up study [J].
Bhatt, V ;
Chhabra, P ;
Dover, MS .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (06) :756-760
[4]   Efficacy and safety of biodegradable osteofixation devices in oral and maxillofacial surgery: a systematic review [J].
Buijs, G. J. ;
Stegenga, B. ;
Bos, R. R. M. .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (11) :980-989
[5]   Mechanical strength and stiffness of biodegradable and titanium osteofixation systems [J].
Buijs, Gerrit J. ;
van der Houwen, Eduard B. ;
Bos, Rudulf R. M. ;
Verkerke, Gijsbertus J. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (11) :2148-2158
[6]   Torsion strength of biodegradable and titanium screws: A comparison [J].
Buijs, Gerritj ;
van der Houwen, Eduard B. ;
Stegenga, Boudewyn ;
Bos, Rudulf R. M. ;
Verkerke, Gsbeffus J. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (11) :2142-2147
[7]  
Buijs GJ, 2011, THESIS
[8]  
Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
[9]  
Dambrain R., 1993, Revue de Stomatologie et de Chirurgie Maxillo-Faciale, V94, P140
[10]   Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial [J].
Gareb, B. ;
van Bakelen, N. B. ;
Buijs, G. J. ;
Jansma, J. ;
de Visscher, J. G. A. M. ;
Hoppenreijs, Th. J. M. ;
Bergsma, J. E. ;
van Minnen, B. ;
Stegenga, B. ;
Bos, R. R. M. .
PLOS ONE, 2017, 12 (05)