Optimization of instrument setup and post-run corrections for oxygen and hydrogen stable isotope measurements of water by isotope ratio infrared spectroscopy (IRIS)

被引:193
作者
van Geldern, Robert [1 ]
Barth, Johannes A. C. [1 ]
机构
[1] Univ Erlangen Nurnberg, GeoZentrum Nordbayern, D-91054 Erlangen, Germany
来源
LIMNOLOGY AND OCEANOGRAPHY-METHODS | 2012年 / 10卷
关键词
RING-DOWN SPECTROSCOPY; CHROMIUM REDUCTION; SAMPLES; DELTA-O-18; PRECISION; DELTA-H-2; NORMALIZATION; SPECTROMETRY; CALIBRATION; EXTRACTION;
D O I
10.4319/lom.2012.10.1024
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Light stable isotope analyses of hydrogen (H-2/H-1) and oxygen (O-18/O-16) of water are used in many terrestrial and marine aquatic studies. The advantage of using stable isotope ratios is that water molecules serve as ubiquitous and already present natural tracers. Within recent years, these analyses have been revolutionized by the development of new isotope ratio laser spectroscopy (IRIS) systems that are cheaper, more robust, and mobile compared with traditional isotope ratio mass spectrometry (IRMS). Although easier to operate, laser systems also need thorough calibration with international reference materials, and raw data need correction for analytical effects (i.e., memory and drift). This study presents modifications to the hardware for liquid water injection, an optimized sequence layout and a simple post-run correction procedure. These protocols will maximize precision, accuracy, and sample throughput via an efficient memory correction. The number of injections per unknown sample can be reduced to 4 or less. This procedure meets the demands of faster throughput with reduced costs per analysis. Procedures presented here are based on real analyses. They were also verified by an international proficiency test and traditional IRMS techniques.
引用
收藏
页码:1024 / 1036
页数:13
相关论文
共 32 条
[1]  
[Anonymous], 2006, GLOB NETW IS PREC GN
[2]  
[Anonymous], HDB STABLE ISOTOPE A
[3]  
[Anonymous], 1998, ISOTOPE TRACERS CATC, DOI DOI 10.1016/C2009-0-10239-8
[4]   Automated analyses of 18O/16O ratios in dissolved oxygen from 12-mL water samples [J].
Barth, JAC ;
Tait, A ;
Bolshaw, M .
LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2004, 2 :35-41
[5]   STABLE ISOTOPES OF OXYGEN AND HYDROGEN IN THE TRUCKEE RIVER PYRAMID LAKE SURFACE-WATER SYSTEM .1. DATA-ANALYSIS AND EXTRACTION OF PALEOCLIMATIC INFORMATION [J].
BENSON, LV .
LIMNOLOGY AND OCEANOGRAPHY, 1994, 39 (02) :344-355
[6]   Cavity ring-down spectroscopy versus high-temperature conversion isotope ratio mass spectrometry; a case study on δ2H and δ18O of pure water samples and alcohol/water mixtures [J].
Brand, Willi A. ;
Geilmann, Heike ;
Crosson, Eric R. ;
Rella, Chris W. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (12) :1879-1884
[7]  
Brooks P. D., 2004, JOINT EUR STABL IS U
[8]   Analysis of the hydrogen and oxygen stable isotope ratios of beverage waters without prior water extraction using isotope ratio infrared spectroscopy [J].
Chesson, Lesley A. ;
Bowen, Gabriel J. ;
Ehleringer, James R. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (21) :3205-3213
[9]  
Clark I., 1997, ENV ISOTOPES HYDROLO
[10]  
COPLEN TB, 2000, 00345 USGS