Voltammetric Characterization of Ion-Ionophore Complexation Using Thin Polymeric Membranes: Asymmetric Thin-Layer Responses

被引:19
作者
Greenawalt, Peter J. [1 ]
Garada, Mohammed B. [1 ]
Amemiya, Shigeru [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
基金
美国国家科学基金会;
关键词
WATER-NITROBENZENE INTERFACE; ALKALI-METAL IONS; SELECTIVE ELECTRODES; FORMATION CONSTANTS; CYCLIC VOLTAMMETRY; DETECTION LIMIT; STRIPPING VOLTAMMETRY; LIQUID-MEMBRANE; DRINKING-WATER; ANIONIC SITES;
D O I
10.1021/acs.analchem.5b02355
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selective ion-ionophore complexation in a polymeric membrane is crucial to various sensing applications. In this work, we report on a novel voltammetric approach based on a thin polymeric membrane to determine the stoichiometry and overall formation constant of an ion-ionophore complex. With this approach, a similar to 1.6 mu m thick ionophore-doped membrane contacts an aqueous solution containing an excess amount of a target ion to facilitate voltammetric ion transfer across the membrane/water interface. Advantageously, the resultant thin-layer voltammogram shows no diffusional effect, which simplifies the theoretical modeling and quantitative analysis of the voltammogram. We predict theoretically that the complexation stoichiometry affects not only the peak current and peak potential of the thin-layer voltammogram, but also the symmetry of the peak shape with respect to the peak potential. Experimentally, a symmetric voltammogram ensures the formation of a 1:1 complex for a Na+-selective ionophore. By contrast, the asymmetric shape and peak current of voltammograms are used to demonstrate that a Ca2+-selective ionophore forms 1:3 and 1:2 complexes with calcium and magnesium ions, respectively. The complexation stoichiometry is needed to yield the formation constants that are consistent with those determined previously by potentiometry. In addition, both 1:2 and 1:1 complexes are voltammetrically observed with another Na+-selective ionophore, which was assumed to form only a 1:2 complex in previous potentiometric studies. The formation constants of both complexes are determined from a single voltammogram to reveal that the preceding formation of a 1:2 complex thermodynamically hampers the voltammetric observation of a 1:1 complex.
引用
收藏
页码:8564 / 8572
页数:9
相关论文
共 47 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]  
Amemiya S., 2013, Specialist Periodical Reports in Electrochemistry, V12, P1
[3]  
Amemiya S, 2007, HANDBOOK OF ELECTROCHEMISTRY, P261, DOI 10.1016/B978-044451958-0.50020-3
[4]   Electrochemical sensing and imaging based on ion transfer at liquid/liquid interfaces [J].
Amemiya, Shigeru ;
Kim, Jiyeon ;
Izadyar, Anahita ;
Kabagambe, Benjamin ;
Shen, Mei ;
Ishimatsu, Ryoichi .
ELECTROCHIMICA ACTA, 2013, 110 :836-845
[5]   Monitoring Pb2+ with optical sensing films [J].
Anticó, E ;
Lerchi, M ;
Rusterholz, B ;
Achermann, N ;
Badertscher, M ;
Valiente, M ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1999, 388 (03) :327-338
[6]   SELECTIVITY OF POLYMER MEMBRANE-BASED ION-SELECTIVE ELECTRODES - SELF-CONSISTENT MODEL DESCRIBING THE POTENTIOMETRIC RESPONSE IN MIXED ION SOLUTIONS OF DIFFERENT CHARGE [J].
BAKKER, E ;
MERUVA, RK ;
PRETSCH, E ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3021-3030
[7]   Ion-selective electrodes based on two competitive ionophores for determining effective stability constants of ion-carrier complexes in solvent polymer membranes [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :295-302
[8]   DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES [J].
BAKKER, E ;
WILLER, M ;
LERCHI, M ;
SEILER, K ;
PRETSCH, E .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :516-521
[9]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[10]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132