Practical operation of a biaxial goniometer at the wrist joint

被引:55
作者
Buchholz, B
Wellman, H
机构
[1] Department of Work Environment, University of Massachusetts Lowell, Lowell, MA
[2] Department of Work Environment, University of Massachusetts Lowell, Lowell, MA 01854
[3] Massachusetts Dept. of Public Health, Bureau of Labor Statistics, Boston, MA
关键词
CUMULATIVE TRAUMA DISORDERS; FLEXIBLE ELECTROGONIOMETER; SYSTEM;
D O I
10.1518/001872097778940696
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
The objectives of this study were (a) to determine errors in wrist angle measurements from a commercially available biaxial electrogoniometer and (b) to develop a calibration routine in order to correct for these errors. Goniometric measurements were collected simultaneously with true angular data using a fixture that allowed wrist movement in one plane while restricting motion in the orthogonal plane. These data were collected in two sets of trials: flexion/extension with radial/ulnar deviation restricted, and radial/ulnar deviation with flexion/extension restricted. During these trials, we studied discrete 30 degrees increments of forearm rotation. The results showed the expected cross talk and zero drift errors during forearm rotation. The application of mathematical equations that describe the effect of goniometer twist resulted in significant error reduction for most forearm rotations. The calibration technique employs both a slope and a displacement transformation to improve the accuracy of angular data. The calibration technique may be used on data collected in the field if forearm rotation is measured simultaneously with the goniometer data.
引用
收藏
页码:119 / 129
页数:11
相关论文
共 16 条
[1]  
ARMSTRONG T, 1993, 24 C INT COMM OCC HL
[2]   INVESTIGATION OF CUMULATIVE TRAUMA DISORDERS IN A POULTRY-PROCESSING PLANT [J].
ARMSTRONG, TJ ;
FOULKE, JA ;
JOSEPH, BS ;
GOLDSTEIN, SA .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1982, 43 (02) :103-116
[3]  
ARMSTRONG TJ, 1986, HAND CLIN, V2, P553
[4]   RELIABILITY OF HINDFOOT GONIOMETRY WHEN USING A FLEXIBLE ELECTROGONIOMETER [J].
BALL, P ;
JOHNSON, GR .
CLINICAL BIOMECHANICS, 1993, 8 (01) :13-19
[5]  
BOOCOCK MG, 1994, EROGNOMICS, V37, P173
[6]  
CASOLO F, 1990, 1 WORKD C BIOM SAN D
[7]  
GARRETT JW, 1970, AMRLTR6942AER MED DI
[8]  
GARRETT JW, 1970, AMRLTR6926 AER MED D
[9]   WRIST MOTIONS IN INDUSTRY [J].
MARRAS, WS ;
SCHOENMARKLIN, RW .
ERGONOMICS, 1993, 36 (04) :341-351
[10]   QUANTIFYING EXPOSURE IN OCCUPATIONAL MANUAL TASKS WITH CUMULATIVE TRAUMA DISORDER POTENTIAL [J].
MOORE, A ;
WELLS, R ;
RANNEY, D .
ERGONOMICS, 1991, 34 (12) :1433-1453