This prospective, double-blind, randomised controlled trial was designed to address the following research questions: firstly, is there a significant difference in outliers in alignment in the frontal and sagittal plane between PSG TKA and conventional TKA. Secondly, is there a significant difference in operation time, blood loss and length of hospital stay between the two techniques. We hypothesise that there will be fewer outliers with PSG TKA and that operation time, blood loss and length of hospital stay can be significantly reduced with PSG. A total of 180 patients were randomised for PSG TKA (group 1) or conventional TKA (group 2) in two centres. Patients were stratified per hospital. Alignment of the mechanical axis of the leg and flexion/extension and varus/valgus of the individual prosthesis components were measured on digital, standing, long-leg and standard lateral radiographs by two independent outcome assessors in both centres. Percentages of outliers (> 3A degrees) were determined. We compared blood loss, operation time and length of hospital stay. There was no statistically significant difference in mean mechanical axis or outliers in mechanical axis between groups. No statistically significant difference was found for the alignment of the individual components in the frontal plane nor for the percentages of outliers. There was a statistically significant difference in outliers for the femoral component in the sagittal plane, with a higher percentage of outliers in the group 1 (p = 0.017). No such significant result was found for the tibial component in that plane. All interclass correlation coefficients were good. Blood loss was 100 mL less in group 1 (p < 0.001). Operation time was 5 min shorter in group 1 (p < 0.001). Length of hospital stay was identical with a mean of 3.6 days (p = 0.657). The results in terms of obtaining a neutral mechanical axis and a correct position of the prosthesis components did not differ between groups. A small reduction in operation time and blood loss was found with the PSG system. Future research should especially focus on cost-effectiveness analysis and functional outcome of PSG TKA. I.
引用
收藏
页码:2206 / 2212
页数:7
相关论文
共 15 条
  • [1] Preliminary experience with the patient-specific templating total knee arthroplasty 40 cases compared with a matched control group
    Boonen, Bert
    Schotanus, Martijn G. M.
    Kort, Nanne P.
    [J]. ACTA ORTHOPAEDICA, 2012, 83 (04) : 387 - 393
  • [2] A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement
    Chareancholvanich, K.
    Narkbunnam, R.
    Pornrattanamaneewong, C.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (03) : 354 - 359
  • [3] Evaluation of the accuracy of a patient-specific instrumentation by navigation
    Conteduca, Fabio
    Iorio, Raffaele
    Mazza, Daniele
    Caperna, Ludovico
    Bolle, Gabriele
    Argento, Giuseppe
    Ferretti, Andrea
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2194 - 2199
  • [4] Frontal plane alignment after total knee arthroplasty using patient-specific instruments
    Daniilidis, Kiriakos
    Tibesku, Carsten O.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (01) : 45 - 50
  • [5] International survey of primary and revision total knee replacement
    Kurtz, Steven M.
    Ong, Kevin L.
    Lau, Edmund
    Widmer, Marcel
    Maravic, Milka
    Gomez-Barrena, Enrique
    de Pina, Maria de Fatima
    Manno, Valerio
    Torre, Marina
    Walter, William L.
    de Steiger, Richard
    Geesink, Rudolph G. T.
    Peltola, Mikko
    Roeder, Christoph
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (12) : 1783 - 1789
  • [6] Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty
    Lustig, Sebastien
    Scholes, Corey J.
    Oussedik, Sam I.
    Kinzel, Vera
    Coolican, Myles R. J.
    Parker, David A.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 469 - 473
  • [7] Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery
    Mason, J. Bohannon
    Fehring, Thomas K.
    Estok, Rhonda
    Banel, Deirdre
    Fahrbach, Kyle
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (08) : 1097 - 1106
  • [8] RADIOGRAPHIC ANALYSIS OF THE AXIAL ALIGNMENT OF THE LOWER-EXTREMITY
    MORELAND, JR
    BASSETT, LW
    HANKER, GJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05) : 745 - 749
  • [9] Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty
    Nam, Denis
    Maher, Patrick A.
    Rebolledo, Brian J.
    Nawabi, Danyal H.
    McLawhorn, Alexander S.
    Pearle, Andrew D.
    [J]. KNEE, 2013, 20 (04) : 263 - 267
  • [10] Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA
    Ng, Vincent Y.
    DeClaire, Jeffrey H.
    Berend, Keith R.
    Gulick, Bethany C.
    Lombardi, Adolph V., Jr.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) : 99 - 107