Integral porous femoral stem - 5- to 8-year follow-up study

被引:12
作者
Mauerhan, DR
Mesa, J
Gregory, AM
Mokris, JG
机构
[1] Miller Orthopaedic Clinic, Charlotte, NC
[2] Rothman Institute, Philadelphia, PA
[3] Miller Orthopaedic Clinic, Charlotte, NC 28203
关键词
arthroplasty; integral femoral stem; uncemented hip prosthesis; arthritis;
D O I
10.1016/S0883-5403(97)90020-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The outcome of total hip arthroplasty without cement was prospectively followed in patients who received a titanium taper wedge femoral component with a circumferential titanium plasma spray coating on the proximal surface (Integral femoral stem, Biomet, Warsaw, IN). One hundred ninety femoral components were implanted in 179 patients. Nine patients (9 hips) died prior to their 5-year examination, leaving 170 patients available for follow-up evaluation. Thirty-one of the 170 patients (33 hips) were lost at an intermediate follow-up period of 5 years (mean, 5.8 years, range; 5-8 years), giving a follow-up rate of 82% for patients and hips. The preoperative diagnoses included osteoarthritis (91 hips), avascular necrosis (38), post-traumatic arthritis (10), rheumatoid arthritis (4), congenital dislocation of the hip (3), and fractures (2). The 78 men and 61 women had a mean age of 55 years (range, 18-81 years) and a mean weight of 81 kg (range, 50-136 kg). Preoperative Harris pain and function scores for the hip were 19.9 (range, 0-40) and 55.6 (range, 12-84), respectively. At the most recent follow-up visit, the mean pain score increased to 41.2 (range, 10-44) and the mean function score increased to 93.5 (range, 6-100). Thigh pain was present in 4% of the hips at the most recent follow-up visit. Radiographically, 99% of the femoral components demonstrated spot welds in the porous-coated zone. Two hips had demarcation of the femoral component in the porous-coated zone consistent with fibrous fixation. None of the femoral stems had been revised and there were no signs of aseptic loosening. Additionally, there were no cases of pain that could be directly attributed to the stem and there was no evidence of distal femoral osteolysis. It is concluded that the Integral femoral stem provides excellent clinical and radiographic results at intermediate follow-up periods.
引用
收藏
页码:250 / 255
页数:6
相关论文
共 50 条
[31]   Total Hip Arthroplasty for Failed Treatment of Acetabular Fractures A 5-Year Follow-Up Study [J].
Zhang, Liang ;
Zhou, Yixin ;
Li, Yujun ;
Xu, Hui ;
Guo, Xiaozhong ;
Zhou, Yixiong .
JOURNAL OF ARTHROPLASTY, 2011, 26 (08) :1189-1193
[32]   Targeted partial arthroscopic trapeziectomy with temporary distraction: a retrospective study with 5-year follow-up [J].
Bargemon, Jean-Baptiste De Villeneuve ;
Lupon, Elise ;
Soude, Guillaume ;
Jaloux, Charlotte ;
Levet, Paul ;
Levadoux, Michel .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (10) :1062-1067
[33]   Asian-Specific total knee system: 5-14 year follow-up study [J].
Hosaka, Kunihiro ;
Saito, Shu ;
Ishii, Takao ;
Mori, Sei ;
Sumino, Takanobu ;
Tokuhashi, Yasuaki .
BMC MUSCULOSKELETAL DISORDERS, 2011, 12
[34]   Total hip arthroplasty in patients less than 40 years old with avascular necrosis of the femoral head A 5 to 19-year follow-up study [J].
Simon, Jean-Pierre ;
Berger, Pieter ;
Bellemans, Johan .
ACTA ORTHOPAEDICA BELGICA, 2011, 77 (01) :53-60
[35]   Cemented versus uncemented total hip replacement for femoral neck fractures in elderly patients: a retrospective, multicentre study with a mean 5-year follow-up [J].
Mao, Shuai ;
Chen, Baomin ;
Zhu, Ying ;
Qian, Liang ;
Lin, Jinluan ;
Zhang, Xinchao ;
Yu, Weiguang ;
Han, Guowei .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
[36]   Kyphoplasty for Intractable Pain Due to Glucocorticosteroid-induced Osteoporotic Vertebra Fracture of a 9-Year-Old Patient With Systemic Lupus Erythematosus: 8-Year Follow-up [J].
Kanatli, Ulunay ;
Ataoglu, Baybars ;
Ozer, Mustafa ;
Senkoylu, Alpaslan ;
Cetinkaya, Mehmet .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2015, 35 (06) :E55-E59
[37]   Impaction grafting for femoral component revision using a non-polished bead-blasted chrome cobalt stem - Average 8 1/2-year follow-up [J].
Krupp, Ryan J. ;
Malkani, Arthur L. ;
Crawford, Charles H. ;
Capello, William N. ;
Feinberg, Judy R. ;
Baker, Dale .
JOURNAL OF ARTHROPLASTY, 2006, 21 (08) :1180-1186
[38]   Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up [J].
Cinotti, G. ;
Della Rocca, A. ;
Sessa, P. ;
Ripani, F. R. ;
Giannicola, G. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (01) :30-36
[39]   The use of a long stem cemented femoral component in revision total hip replacement A FOLLOW-UP STUDY OF FIVE TO 16 YEARS [J].
te Stroet, M. A. J. ;
Bronsema, E. ;
Rijnen, W. H. C. ;
Gardeniers, J. W. M. ;
Schreurs, B. W. .
BONE & JOINT JOURNAL, 2014, 96B (09) :1207-1213
[40]   Improvement in knee osteoarthritis pain and function following bariatric surgery: 5-year follow-up [J].
Hacken, Brittney ;
Rogers, Ann ;
Chinchilli, Vernon ;
Silvis, Matthew ;
Mosher, Timothy ;
Black, Kevin .
SURGERY FOR OBESITY AND RELATED DISEASES, 2019, 15 (06) :979-984