Integral porous femoral stem - 5- to 8-year follow-up study

被引:12
作者
Mauerhan, DR
Mesa, J
Gregory, AM
Mokris, JG
机构
[1] Miller Orthopaedic Clinic, Charlotte, NC
[2] Rothman Institute, Philadelphia, PA
[3] Miller Orthopaedic Clinic, Charlotte, NC 28203
关键词
arthroplasty; integral femoral stem; uncemented hip prosthesis; arthritis;
D O I
10.1016/S0883-5403(97)90020-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The outcome of total hip arthroplasty without cement was prospectively followed in patients who received a titanium taper wedge femoral component with a circumferential titanium plasma spray coating on the proximal surface (Integral femoral stem, Biomet, Warsaw, IN). One hundred ninety femoral components were implanted in 179 patients. Nine patients (9 hips) died prior to their 5-year examination, leaving 170 patients available for follow-up evaluation. Thirty-one of the 170 patients (33 hips) were lost at an intermediate follow-up period of 5 years (mean, 5.8 years, range; 5-8 years), giving a follow-up rate of 82% for patients and hips. The preoperative diagnoses included osteoarthritis (91 hips), avascular necrosis (38), post-traumatic arthritis (10), rheumatoid arthritis (4), congenital dislocation of the hip (3), and fractures (2). The 78 men and 61 women had a mean age of 55 years (range, 18-81 years) and a mean weight of 81 kg (range, 50-136 kg). Preoperative Harris pain and function scores for the hip were 19.9 (range, 0-40) and 55.6 (range, 12-84), respectively. At the most recent follow-up visit, the mean pain score increased to 41.2 (range, 10-44) and the mean function score increased to 93.5 (range, 6-100). Thigh pain was present in 4% of the hips at the most recent follow-up visit. Radiographically, 99% of the femoral components demonstrated spot welds in the porous-coated zone. Two hips had demarcation of the femoral component in the porous-coated zone consistent with fibrous fixation. None of the femoral stems had been revised and there were no signs of aseptic loosening. Additionally, there were no cases of pain that could be directly attributed to the stem and there was no evidence of distal femoral osteolysis. It is concluded that the Integral femoral stem provides excellent clinical and radiographic results at intermediate follow-up periods.
引用
收藏
页码:250 / 255
页数:6
相关论文
共 50 条
  • [1] Partial trapeziectomy and pyrocarbon interpositional arthroplasty for trapeziometacarpal osteoarthritis: minimum 8-year follow-up
    Smeraglia, Francesco
    Barrera-Ochoa, Sergi
    Mendez-Sanchez, Gerardo
    Basso, Morena A.
    Balato, Giovanni
    Mir-Bullo, Xavier
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (05) : 472 - 476
  • [2] 5-year clinical and radiographic follow-up of the uncemented Symax hip stem in an international study
    Kruijntjens, Dennis Silvester Maria Gerardus
    Kjaersgaard-Andersen, Per
    Revald, Peter
    Leonhardt, Jane Schwartz
    Arts, Jacobus Johannes Chris
    ten Broeke, Rene Hendrikus Maria
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [3] Total Wrist Arthroplasty With a New Design: 20 Cases With 8-Year Follow-Up
    Reiser, Daniel
    Fischer, Per
    Pettersson, Kurt
    Wretenberg, Per
    Sagerfors, Marcus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (03): : 377e1 - 377e8
  • [4] A 5-8 Year Retrospective Follow-Up of the C-Stem AMT Femoral Component: Patient Reported Outcomes and Survivorship Analysis
    Berstock, James R.
    Whitehouse, Michael R.
    Piper, Danielle C.
    Eastaugh-Waring, Stephen J.
    Blom, Ashley W.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 1753 - 1757
  • [5] Total knee arthroplasty with an oxidised zirconium femoral component: a 5-year follow-up study
    Park, Derek H.
    Leong, Julian
    Palmer, Stephen J.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01): : 75 - 79
  • [6] Cementless titanium tapered-wedge femoral stem - 10-to 15-year follow-up
    Marshall, AD
    Mokris, JG
    Reitman, RD
    Dandar, A
    Mauerhan, DR
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05) : 546 - 552
  • [7] A well-fixed femoral stem facing a failed acetabular component: To exchange or not? A 5-to 15-year follow-up study
    de Thomasson, E.
    Conso, C.
    Mazel, C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (01) : 24 - 29
  • [8] 8-year follow-up after cementless hip arthroplasty with a second generation spongy metal total hip replacement
    Gollwitzer, Hans
    Gerdesmeyer, Ludger
    Horn, Carsten
    Diehl, Peter
    Toepfer, Andreas
    Gradinger, Reiner
    HIP INTERNATIONAL, 2009, 19 (04) : 359 - 366
  • [9] Acetabular reconstruction using a Kerboull-type acetabular reinforcement device and hydroxyapatite granules - A 3-to 8-year follow-up study
    Tanaka, C
    Shikata, J
    Ikenaga, M
    Takahashi, M
    JOURNAL OF ARTHROPLASTY, 2003, 18 (06) : 719 - 725
  • [10] The Journey patellofemoral joint arthroplasty: A minimum 5 year follow-up study
    Ahearn, Nathanael
    Metcalfe, Andrew J.
    Hassaballa, Mohammed A.
    Porteous, Andrew J.
    Robinson, James R.
    Murray, James R.
    Newman, John H.
    KNEE, 2016, 23 (05) : 900 - 904