Compressive behaviour of slender FRP-confined concrete-encased cross-shaped steel columns

被引:25
作者
Huang, Le [1 ]
Yu, Tao [1 ,2 ]
Wang, Zhen-Yu [3 ]
Zhang, Shi-Shun [4 ]
机构
[1] Univ Wollongong, Fac Engn & Informat Sci, Sch Civil Min & Environm Engn, Wollongong, NSW, Australia
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hung Hom, Kowloon, Hong Kong, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin, Peoples R China
[4] Huazhong Univ Sci & Technol, Sch Civil Engn & Mech, Wuhan, Peoples R China
基金
澳大利亚研究理事会; 中国国家自然科学基金;
关键词
Fibre-reinforced polymer (FRP); Concrete; Steel section; Hybrid columns; Tubular columns; Slender columns; Eccentric compression; SQUARE RC COLUMNS; TUBULAR COLUMNS; LONGITUDINAL CFRP; CAPACITY;
D O I
10.1016/j.conbuildmat.2020.120356
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fibre-reinforced polymer (FRP)-confined concrete-encased cross-shaped steel columns (FCCSCs) consist of a square FRP outer tube with round corners, a cross-shaped inner steel section and concrete filled in the between. The unique configuration of FCCSCs ensures that the concrete in the columns is well con-fined despite the square column shape, as demonstrated by the relevant existing research. The existing work on FCCSCs, however, has been limited to the behavior of short FCCSCs under axial compression. With their optimal configuration, the use of FCCSCs means that considerably reduced section dimensions may be adopted for the same load demand, leading to relatively slender columns in practice. In addition, the load eccentricity is an important parameter to consider in the column design. This paper presents the first-ever experimental study on the behaviour of slender FCCSCs. The test variables in this study included the load eccentricity, the slenderness ratio of the column and the thickness of FRP tube. The test results confirm the excellent structural performance of slender FCCSCs, and show that the load capacity of FCCSCs decreases with the slenderness ratio and the load eccentricity. Nevertheless, the confinement effects on the behavior of FCCSCs were found to be remarkable even when the column slenderness ratio and load eccentricity are large. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:18
相关论文
共 37 条
[1]  
[Anonymous], 2005, 41 BS
[2]  
[Anonymous], 1987, 18 BSI
[3]  
[Anonymous], 2016, 36791 ASNZS
[4]  
[Anonymous], 2004, STANDARD TEST METHOD
[5]  
[Anonymous], 2014, AS1012.9
[6]  
Beer F.P., 2016, Statics and mechanics of materials
[7]   Square FRP-HSC-steel composite columns: Behavior under axial compression [J].
Fanggi, Butje Alfonsius Louk ;
Ozbakkaloglu, Togay .
ENGINEERING STRUCTURES, 2015, 92 :156-171
[8]   Mechanical behavior of concrete-filled square steel tube with FRP-confined concrete core subjected to axial compression [J].
Feng, Peng ;
Cheng, Shi ;
Bai, Yu ;
Ye, Lieping .
COMPOSITE STRUCTURES, 2015, 123 :312-324
[9]   Slenderness Effects on Circular CFRP Confined Reinforced Concrete Columns [J].
Fitzwilliam, Jason ;
Bisby, Luke A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (03) :280-288
[10]  
Hollaway LC, 2008, WOODHEAD PUBL MATER, P1