On-board calibration system for millimeter-wave radiometers based on reference-polarized signal injection

被引:6
作者
Peverini, OA [1 ]
Tascone, R
Carretti, E
Virone, G
Olivieri, A
Orta, R
Cortiglioni, S
Monari, J
机构
[1] Ist Elettron & Ingn Informaz & Telecomun, I-10129 Turin, Italy
[2] Natl Astrophys Inst Italy, I-40129 Bologna, Italy
关键词
calibration techniques; millimeter waves; radiometers; waveguide components;
D O I
10.1109/TMTT.2005.860496
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the architecture of a novel on-hoard calibration system for millimeter-wave radiometers aimed at measuring the Q, U Stokes parameters of the sky emission. This technique requires the injection of differently polarized reference signals, which is carried out by means of a specific component mounted in the antenna-feed system. The presented technique was developed by Cortiglioni et al. for the calibration of the Balloon-borne Radiometers for Sky Polarization Observations radiometers, specifically designed to measure the polarized sky emission by a correlation technique. A procedure for the accurate evaluation of the polarization state of the calibration signals is also reported. Numerical and experimental results are presented for the K alpha-band calibrator in the operational conditions.
引用
收藏
页码:412 / 420
页数:9
相关论文
共 17 条
[1]   Limits due to instrumental polarisation in CMB experiments at microwave wavelengths [J].
Carretti, E ;
Tascone, R ;
Cortiglioni, S ;
Monari, J ;
Orsini, M .
NEW ASTRONOMY, 2001, 6 (03) :173-187
[2]   On-board accurate calibration of dual-channel radiometers using internal and external references [J].
Corbella, I ;
Gasiewski, AJ ;
Klein, M ;
Leuski, V ;
Francavilla, AJ ;
Piepmeier, JR .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2002, 50 (07) :1816-1820
[3]   The Sky Polarization Observatory [J].
Cortiglioni, S ;
Bernardi, G ;
Carretti, E ;
Casarini, L ;
Cecchini, S ;
Macculi, C ;
Ramponi, M ;
Sbarra, C ;
Monari, J ;
Orfei, A ;
Poloni, M ;
Poppi, S ;
Boella, G ;
Bonometto, S ;
Colombo, L ;
Gervasi, M ;
Sironi, G ;
Zannoni, M ;
Baralis, M ;
Peverini, OA ;
Tascone, R ;
Virone, G ;
Fabbri, R ;
Natale, V ;
Nicastro, L ;
Ng, KW ;
Vinyajkin, EN ;
Razin, VA ;
Sazhin, MV ;
Strukov, IA ;
Negri, B .
NEW ASTRONOMY, 2004, 9 (04) :297-327
[4]  
Cortiglioni S, 2003, ESA SPEC PUBL, V530, P271
[5]   CALIBRATION AND APPLICATIONS OF POLARIZATION-CORRELATING RADIOMETERS [J].
GASIEWSKI, AJ ;
KUNKEE, DB .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1993, 41 (05) :767-773
[6]  
Itoh T., 1989, NUMERICAL TECHNIQUES
[7]  
KRAUS J, 1996, RADIO ASTRONOMY, pCH4
[8]   A calibration method for fully polarimetric microwave radiometers [J].
Lahtinen, J ;
Gasiewski, AJ ;
Klein, M ;
Corbella, I .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (03) :588-602
[9]   HUT fully polarimetric calibration standard for microwave radiometry [J].
Lahtinen, J ;
Hallikainen, MT .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (03) :603-611
[10]   Calibration of millimeter-wave polarimeters using a thin dielectric sheet [J].
O'Dell, CW ;
Swetz, DS ;
Timbie, PT .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2002, 50 (09) :2135-2141