Accuracy of flash glucose monitoring in insulin-treated patients with type 2 diabetes

被引:27
作者
Sato, Tatsuya [1 ,2 ]
Oshima, Hiroto [1 ]
Nakata, Kei [1 ]
Kimura, Yukishige [1 ]
Yano, Toshiyuki [1 ]
Furuhashi, Masato [1 ]
Tanno, Masaya [1 ]
Miki, Takayuki [1 ]
Miura, Tetsuji [1 ]
机构
[1] Sapporo Med Univ, Sch Med, Dept Cardiovasc Renal & Metab Med, Sapporo, Hokkaido, Japan
[2] Sapporo Med Univ, Sch Med, Dept Cellular Physiol & Signal Transduct, Sapporo, Hokkaido, Japan
基金
日本学术振兴会;
关键词
Continuous glucose monitoring; Diabetes mellitus; Flash glucose monitoring; SENSING TECHNOLOGY; GLYCEMIC CONTROL; FREESTYLE LIBRE; MULTICENTER; SYSTEM; ADULTS; HYPOGLYCEMIA; INJECTIONS;
D O I
10.1111/jdi.12954
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The present study evaluated the accuracy of interstitial glucose measurements by flash glucose monitoring (FGM) and continuous glucose monitoring (CGM). Five diabetes patients simultaneously underwent FGM (FreeStyle Libre Pro) and CGM (iPro (TM) 2), and their glucose levels were compared with venous blood and capillary blood glucose levels. The range of daily venous blood glucose levels (30 measurements) was 70-245 mg/dL, with a median of 138 mg/dL. There were good correlations of glucose levels measured by FGM (r(2) = 0.90, mean absolute relative difference 8.2 +/- 5.6%), CGM (r(2) = 0.86, mean absolute relative difference 9.2 +/- 9.1%) and capillary blood (r(2) = 0.87, mean absolute relative difference 7.2 +/- 7.2%) with venous blood glucose levels. The accuracy of FGM measurements was also shown against CGM, with 99.9% of the FGM values (1,279 measurements) being within the Parkes error grid zones A and B. The results suggest that the accuracy of FGM is similar to that of CGM, and that FGM is a useful tool for determining daily glucose profile.
引用
收藏
页码:846 / 850
页数:5
相关论文
共 19 条
  • [1] Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes
    Aberer, Felix
    Hajnsek, Martin
    Rumpler, Markus
    Zenz, Sabine
    Baumann, Petra M.
    Elsayed, Hesham
    Puffing, Adelheid
    Treiber, Gerlies
    Pieber, Thomas R.
    Sourij, Harald
    Mader, Julia K.
    [J]. DIABETES OBESITY & METABOLISM, 2017, 19 (07) : 1051 - 1055
  • [2] Al Hayek AA, 2017, CLIN MED INSIGHTS EN, V10, P1
  • [3] A Multicenter Real-Life Study on the Effect of Flash Glucose Monitoring on Glycemic Control in Patients with Type 1 and Type 2 Diabetes
    Anjana, Ranjit Mohan
    Kesavadev, Jothydev
    Neeta, Deshpande
    Tiwaskar, Mangesh
    Pradeepa, Rajendra
    Jebarani, Saravanan
    Thangamani, Suresh
    Sastry, Nadiminty Ganapathi
    Kumar, Srivastava Brijendra
    Ramu, Muthu
    Gupta, Pokal Prasanna Kumar
    Vignesh, Jayaprakash
    Chandru, Sundramoorthy
    Kayalvizhi, Sengottuvel
    Jagdish, Padoor Sethuraman
    Uthra, Subash Chandra Bose
    Lovelena, Munawar
    Jyoti, Sah
    Priya, Sengodan Suguna
    Kannan, Alagarsamy
    Mohan, Viswanathan
    Unnikrishnan, Ranjit
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (09) : 533 - 540
  • [4] The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
    Bailey, Timothy
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    Alva, Shridhara
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 787 - 794
  • [5] Time Lag of Glucose From Intravascular to Interstitial Compartment in Humans
    Basu, Ananda
    Dube, Simmi
    Slama, Michael
    Errazuriz, Isabel
    Amezcua, Jose Carlos
    Kudva, Yogish C.
    Peyser, Thomas
    Carter, Rickey E.
    Cobelli, Claudio
    Basu, Rita
    [J]. DIABETES, 2013, 62 (12) : 4083 - 4087
  • [6] Continuous Glucose Monitoring Versus Usual Care in Patients With Type 2 Diabetes Receiving Multiple Daily Insulin Injections A Randomized Trial
    Beck, Roy W.
    Riddlesworth, Tonya D.
    Ruedy, Katrina
    Ahmann, Andrew
    Haller, Stacie
    Kruger, Davida
    McGill, Janet B.
    Polonsky, William
    Price, David
    Aronoff, Stephen
    Aronson, Ronnie
    Toschi, Elena
    Kollman, Craig
    Bergenstal, Richard
    [J]. ANNALS OF INTERNAL MEDICINE, 2017, 167 (06) : 365 - +
  • [7] Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial
    Beck, Roy W.
    Riddlesworth, Tonya
    Ruedy, Katrina
    Ahmann, Andrew
    Bergenstal, Richard
    Haller, Stacie
    Kollman, Craig
    Kruger, Davida
    McGill, Janet B.
    Polonsky, William
    Toschi, Elena
    Wolpert, Howard
    Price, David
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04): : 371 - 378
  • [8] Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial
    Bolinder, Jan
    Antuna, Ramiro
    Geelhoed-Duijvestijn, Petronella
    Kroeger, Jens
    Weitgasser, Raimund
    [J]. LANCET, 2016, 388 (10057) : 2254 - 2263
  • [9] Head-to-head comparison between flash and continuous glucose monitoring systems in outpatients with type 1 diabetes
    Bonora, B.
    Maran, A.
    Ciciliot, S.
    Avogaro, A.
    Fadini, G. P.
    [J]. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2016, 39 (12): : 1391 - 1399
  • [10] Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    [J]. DIABETES, 2003, 52 (11) : 2790 - 2794