Feasibility study of prompt gamma neutron activation analysis (PGNAA) of explosives simulants and bulk material using DD/DT neutron generator

被引:7
作者
Bishnoi, S. [1 ]
Sarkar, P. S. [1 ]
Patel, T. [1 ]
Adhikari, P. S. [1 ]
Sinha, Amar [1 ]
机构
[1] Bhabha Atom Res Ctr, Neutron & Xray Phys Facil, Bombay 400085, Maharashtra, India
来源
INTERNATIONAL CONFERENCE ON RECENT TRENDS IN NUCLEAR PHYSICS-2012 (ICRTNP-2012) | 2013年 / 1524卷
关键词
Prompt gamma neutron activation (PGNAA); Neutron Generator; capture prompt gamma; inelastic prompt gamma;
D O I
10.1063/1.4801732
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Elemental characterization of low Z elements (C, H, Cl, Fe) inside bulk materials were performed using PGNAA technique. Samples having elemental composition similar to explosives were used for such experimentations using moderated DD neutrons as well as DT(14MeV) neutrons. We could observe characteristic prompt capture gamma rays of hydrogen (2.224MeV), nitrogen (10.83 MeV), chlorine (6.11 MeV) and Fe (6.02MeV and 7.63MeV) also inelastic (n,n'gamma) prompt gamma signal (4.43MeV) of carbon. BGO detector has been used for gamma spectrum acquisition. These experimentations has been carried out for initial feasibility studies of detecting prompt gamma lines as a part of PGNAA technique based explosive detection system development. A detail description of experimental set up and procedure has been discussed in paper.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 9 条
[1]  
Agrawal Ashish, 2011, SAMTI 2011
[2]  
Bishnoi S., 2011, P DAE S NUCL PHYS, V56
[3]  
Choudhary Pritty, 2007, SIBTA IND
[4]   USE OF PU-ALPHA-BE AS A CALIBRATED GAMMA RAY SOURCE [J].
DRAKE, DM ;
HOPKINS, JC ;
MARTIN, JT ;
CONDE, H .
NUCLEAR INSTRUMENTS & METHODS, 1968, 62 (03) :349-&
[5]   Conversion factors from counts to chemical ratios for the EURITRACK tagged neutron inspection system [J].
El Kanawati, W. ;
Perot, B. ;
Carasco, C. ;
Eleon, C. ;
Valkovic, V. ;
Sudac, D. ;
Obhodas, J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 654 (01) :621-629
[6]  
IGUCHI T., 2004, 16 WCNDT 2004 CAN
[7]   CHOICE OF DETECTORS FOR IN-VIVO ELEMENTAL ANALYSIS BY COUNTING NATURAL AND NEUTRON-INDUCED GAMMA-RAYS FOR MEDICAL APPLICATIONS [J].
KEHAYIAS, JJ ;
ZHUANG, H ;
DOWLING, L ;
MA, RM ;
MOORE, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :444-447
[8]  
Sinha A., 2008, INDIAN NUCL SOC NEWS, V5
[9]   Pulsed fast/thermal neutron analysis: a technique for explosives detection [J].
Vourvopoulos, G ;
Womble, PC .
TALANTA, 2001, 54 (03) :459-468