A design for improving the sensitivity of a Mach-Zehnder interferometer to chemical and biological measurands

被引:57
作者
Qi, ZM [1 ]
Matsuda, N
Itoh, K
Murabayashi, M
Lavers, CR
机构
[1] Natl Inst Adv Ind Sci & Technol, Nanoarchitecton Res Ctr, Tsukuba, Ibaraki 3058561, Japan
[2] Yokohama Natl Univ, Inst Environm Sci & Technol, Yokohama, Kanagawa 2408501, Japan
[3] Britannia Royal Naval Coll, Dartmouth TQ6 0HJ, Devon, England
关键词
MZI; COWG; adiabatic transition; enhanced evanescent field; sensitivity improvement; buffer layer elimination;
D O I
10.1016/S0925-4005(01)00960-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Integrated optical Mach-Zehnder interferometers (MZIs) composed of graded-index channel waveguides are often used as chemical/ biological sensors. Such MZIs have a relatively low sensitivity because the graded-index active arms have a weak evanescent field. To improve the sensitivity, a channel-planar composite optical waveguide (COWG) is proposed as a substitute for the graded-index active arm. An actual channel-planar COWG was fabricated by sputtering a tapered TiO2 film onto a straight glass channel waveguide prepared by the potassium ion exchange method. Measurement of the evanescent absorption of the dye solution demonstrated a significantly enhanced evanescent field over the TiO2 film region caused by adiabatic transition of the guided mode between the channel waveguide and TiO2 film. Theoretical calculations show that the sensitivity of a glass-based MZI can increase 71 times when the COWG active arm contains a 25 mu thick and 5 mm long tapered TiO2 film. The use of a COWG as the active arm of a glass-based MZI also allows for elimination of the low-index buffer layer because of a large difference in evanescent field between the COWG and channel waveguide. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 12 条
[1]  
BOIARSKI AA, 1991, FIBER SENSORS 3, V1587, P114
[2]   Effects of Langmuir-Blodgett-film gas sensors with integrated optical interferometers [J].
Chen, FS ;
Liu, YQ ;
Xu, Y ;
Qu, LA .
OPTICS LETTERS, 1996, 21 (20) :1700-1702
[3]   A GAS SENSOR BASED ON AN INTEGRATED OPTICAL MACH-ZEHNDER INTERFEROMETER [J].
FABRICIUS, N ;
GAUGLITZ, G ;
INGENHOFF, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :672-676
[4]   Remote opto-chemical sensing with extreme sensitivity: design, fabrication and performance of a pigtailed integrated optical phase-modulated Mach-Zehnder interferometer system [J].
Heideman, RG ;
Lambeck, PV .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 61 (1-3) :100-127
[5]   BIOSENSORS USING INTEGRATED OPTICAL-DEVICES [J].
INGENHOFF, J ;
DRAPP, B ;
GAUGLITZ, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :580-583
[6]   AN INTEGRATED OPTICAL SENSOR FOR MEASURING GLUCOSE-CONCENTRATION [J].
LIU, Y ;
HERING, P ;
SCULLY, MO .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1992, 54 (01) :18-23
[7]   Integrated optical Mach-Zehnder biosensor [J].
Luff, BJ ;
Wilkinson, JS ;
Piehler, J ;
Hollenbach, U ;
Ingenhoff, J ;
Fabricius, N .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1998, 16 (04) :583-592
[8]   A GaAs/AlGaAs-based refractometer platform for integrated optical sensing applications [J].
Maisenholder, B ;
Zappe, HP ;
Kunz, RE ;
Riel, P ;
Moser, M ;
Edlinger, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) :324-329
[9]   TAPERED VELOCITY COUPLERS FOR INTEGRATED OPTICS - DESIGN [J].
MILTON, AF ;
BURNS, WK .
APPLIED OPTICS, 1975, 14 (05) :1207-1212
[10]   Characterization and application of a channel-planar composite waveguide [J].
Qi, ZM ;
Itoh, K ;
Murabayashi, M ;
Lavers, CR .
OPTICS LETTERS, 2000, 25 (19) :1427-1429