3D free-breathing cardiac magnetic resonance fingerprinting

被引:43
作者
Cruz, Gastao [1 ]
Jaubert, Olivier [1 ]
Qi, Haikun [1 ]
Bustin, Aurelien [1 ]
Milotta, Giorgia [1 ]
Schneider, Torben [2 ]
Koken, Peter [3 ]
Doneva, Mariya [3 ]
Botnar, Rene M. [1 ,4 ]
Prieto, Claudia [1 ,4 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] Philips Healthcare, Guildford, England
[3] Philips Res Europe, Hamburg, Germany
[4] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
3D whole heart; low rank; MR fingerprinting; myocardial tissue characterization; quantitative cardiac MRI; T(1)map; T(2)map; INVERSION-RECOVERY; MOTION CORRECTION; SATURATION RECOVERY; MYOCARDIAL T-1; RECONSTRUCTION; QUANTIFICATION; HEART; MRI; RESOLUTION; MOLLI;
D O I
10.1002/nbm.4370
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose To develop a novel respiratory motion compensated three-dimensional (3D) cardiac magnetic resonance fingerprinting (cMRF) approach for whole-heart myocardialT(1)andT(2)mapping from a free-breathing scan. Methods Two-dimensional (2D) cMRF has been recently proposed for simultaneous, co-registeredT(1)andT(2)mapping from a breath-hold scan; however, coverage is limited. Here we propose a novel respiratory motion compensated 3D cMRF approach for whole-heart myocardialT(1)andT(2)tissue characterization from a free-breathing scan. Variable inversion recovery andT(2)preparation modules are used for parametric encoding, respiratory bellows driven localized autofocus is proposed for beat-to-beat translation motion correction and a subspace regularized reconstruction is employed to accelerate the scan. The proposed 3D cMRF approach was evaluated in a standardizedT(1)/T(2)phantom in comparison with reference spin echo values and in 10 healthy subjects in comparison with standard 2D MOLLI, SASHA andT(2)-GraSE mapping techniques at 1.5 T. Results 3D cMRFT(1)andT(2)measurements were generally in good agreement with reference spin echo values in the phantom experiments, with relative errors of 2.9% and 3.8% forT(1)andT(2)(T-2< 100 ms), respectively. in vivo left ventricle (LV) myocardialT(1)values were 1054 +/- 19 ms for MOLLI, 1146 +/- 20 ms for SASHA and 1093 +/- 24 ms for the proposed 3D cMRF; correspondingT(2)values were 51.8 +/- 1.6 ms for T2-GraSE and 44.6 +/- 2.0 ms for 3D cMRF. LV coefficients of variation were 7.6 +/- 1.6% for MOLLI, 12.1 +/- 2.7% for SASHA and 5.8 +/- 0.8% for 3D cMRFT(1), and 10.5 +/- 1.4% for T2-GraSE and 11.7 +/- 1.6% for 3D cMRFT(2). Conclusion The proposed 3D cMRF can provide whole-heart, simultaneous and co-registeredT(1)andT(2)maps with accuracy and precision comparable to those of clinical standards in a single free-breathing scan of about 7 min.
引用
收藏
页数:16
相关论文
共 77 条
  • [61] Free-running 3D whole heart myocardial T1 mapping with isotropic spatial resolution
    Qi, Haikun
    Jaubert, Olivier
    Bustin, Aurelien
    Cruz, Gastao
    Chen, Huijun
    Botnar, Rene
    Prieto, Claudia
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1331 - 1342
  • [62] Online Real-Time Reconstruction of Adaptive TSENSE With Commodity CPU/GPU Hardware
    Roujol, Sebastien
    de Senneville, Baudouin Denis
    Vahala, Erkki
    Sorensen, Thomas Sangild
    Moonen, Chrit
    Ries, Mario
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) : 1658 - 1664
  • [63] Respiratory Bellows Revisited for Motion Compensation: Preliminary Experience for Cardiovascular MR
    Santelli, Claudio
    Nezafat, Reza
    Goddu, Beth
    Manning, Warren J.
    Smink, Jouke
    Kozerke, Sebastian
    Peters, Dana C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 1098 - 1103
  • [64] Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition (CABIRIA)
    Santini, Francesco
    Kawel-Boehm, N.
    Greiser, A.
    Bremerich, J.
    Bieri, O.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 365 - 371
  • [65] Spatial excitation using variable-density spiral trajectories
    Schröder, C
    Börnert, P
    Aldefeld, B
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) : 136 - 141
  • [66] Accurate, precise, simultaneous myocardial T1 and T2 mapping using a radial sequence with inversion recovery and T2 preparation
    Shao, Jiaxin
    Zhou, Ziwu
    Nguyen, Kim-Lien
    Finn, J. Paul
    Hu, Peng
    [J]. NMR IN BIOMEDICINE, 2019, 32 (11)
  • [67] Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping
    Sprinkart, Alois M.
    Luetkens, Julian A.
    Traeber, Frank
    Doerner, Jonas
    Gieseke, Juergen
    Schnackenburg, Bernhard
    Schmitz, Georg
    Thomas, Daniel
    Homsi, Rami
    Block, Wolfgang
    Schild, Hans
    Naehle, Claas P.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [68] Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Stuber, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 476 - 480
  • [69] Acute versus Chronic Myocardial Infarction: Diagnostic Accuracy of Quantitative Native T1 and T2 Mapping versus Assessment of Edema on Standard T2-weighted Cardiovascular MR Images for Differentiation
    Tahir, Enver
    Sinn, Martin
    Bohnen, Sebastian
    Avanesov, Maxim
    Saring, Dennis
    Stehning, Christian
    Schnackenburg, Bernhard
    Eulenburg, Christine
    Wien, Joshua
    Radunski, Ulf K.
    Blankenberg, Stefan
    Adam, Gerhard
    Higgins, Charles B.
    Saeed, Maythem
    Muellerleile, Kai
    Lund, Gunnar K.
    [J]. RADIOLOGY, 2017, 285 (01) : 83 - 91
  • [70] ESPIRiT-An Eigenvalue Approach to Autocalibrating Parallel MRI: Where SENSE Meets GRAPPA
    Uecker, Martin
    Lai, Peng
    Murphy, Mark J.
    Virtue, Patrick
    Elad, Michael
    Pauly, John M.
    Vasanawala, Shreyas S.
    Lustig, Michael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 990 - 1001