3D free-breathing cardiac magnetic resonance fingerprinting

被引:43
作者
Cruz, Gastao [1 ]
Jaubert, Olivier [1 ]
Qi, Haikun [1 ]
Bustin, Aurelien [1 ]
Milotta, Giorgia [1 ]
Schneider, Torben [2 ]
Koken, Peter [3 ]
Doneva, Mariya [3 ]
Botnar, Rene M. [1 ,4 ]
Prieto, Claudia [1 ,4 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] Philips Healthcare, Guildford, England
[3] Philips Res Europe, Hamburg, Germany
[4] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
3D whole heart; low rank; MR fingerprinting; myocardial tissue characterization; quantitative cardiac MRI; T(1)map; T(2)map; INVERSION-RECOVERY; MOTION CORRECTION; SATURATION RECOVERY; MYOCARDIAL T-1; RECONSTRUCTION; QUANTIFICATION; HEART; MRI; RESOLUTION; MOLLI;
D O I
10.1002/nbm.4370
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose To develop a novel respiratory motion compensated three-dimensional (3D) cardiac magnetic resonance fingerprinting (cMRF) approach for whole-heart myocardialT(1)andT(2)mapping from a free-breathing scan. Methods Two-dimensional (2D) cMRF has been recently proposed for simultaneous, co-registeredT(1)andT(2)mapping from a breath-hold scan; however, coverage is limited. Here we propose a novel respiratory motion compensated 3D cMRF approach for whole-heart myocardialT(1)andT(2)tissue characterization from a free-breathing scan. Variable inversion recovery andT(2)preparation modules are used for parametric encoding, respiratory bellows driven localized autofocus is proposed for beat-to-beat translation motion correction and a subspace regularized reconstruction is employed to accelerate the scan. The proposed 3D cMRF approach was evaluated in a standardizedT(1)/T(2)phantom in comparison with reference spin echo values and in 10 healthy subjects in comparison with standard 2D MOLLI, SASHA andT(2)-GraSE mapping techniques at 1.5 T. Results 3D cMRFT(1)andT(2)measurements were generally in good agreement with reference spin echo values in the phantom experiments, with relative errors of 2.9% and 3.8% forT(1)andT(2)(T-2< 100 ms), respectively. in vivo left ventricle (LV) myocardialT(1)values were 1054 +/- 19 ms for MOLLI, 1146 +/- 20 ms for SASHA and 1093 +/- 24 ms for the proposed 3D cMRF; correspondingT(2)values were 51.8 +/- 1.6 ms for T2-GraSE and 44.6 +/- 2.0 ms for 3D cMRF. LV coefficients of variation were 7.6 +/- 1.6% for MOLLI, 12.1 +/- 2.7% for SASHA and 5.8 +/- 0.8% for 3D cMRFT(1), and 10.5 +/- 1.4% for T2-GraSE and 11.7 +/- 1.6% for 3D cMRFT(2). Conclusion The proposed 3D cMRF can provide whole-heart, simultaneous and co-registeredT(1)andT(2)maps with accuracy and precision comparable to those of clinical standards in a single free-breathing scan of about 7 min.
引用
收藏
页数:16
相关论文
共 77 条
  • [1] Joint Myocardial T1 and T2 Mapping Using a Combination of Saturation Recovery and T2-preparation
    Akcakaya, Mehmet
    Weingaertner, Sebastian
    Basha, Tamer A.
    Roujol, Sebastien
    Bellm, Steven
    Nezafat, Reza
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 888 - 896
  • [2] Hybrid-state free precession in nuclear magnetic resonance
    Asslander, Jakob
    Novikov, Dmitry S.
    Lattanzi, Riccardo
    Sodickson, Daniel K.
    Cloos, Martijn A.
    [J]. COMMUNICATIONS PHYSICS, 2019, 2 (1)
  • [3] Low rank alternating direction method of multipliers reconstruction for MR fingerprinting
    Asslander, Jakob
    Cloos, Martijn A.
    Knoll, Florian
    Sodickson, Daniel K.
    Hennig, Juergen
    Lattanzi, Riccardo
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 83 - 96
  • [4] Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
    Atkinson, D
    Hill, DLG
    Stoyle, PNR
    Summers, PE
    Keevil, SF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) : 903 - 910
  • [5] A systematic evaluation of three different cardiac T2-mapping sequences at 1.5 and 3T in healthy volunteers
    Baessler, Bettina
    Schaarschmidt, Frank
    Stehning, Christian
    Schnackenburg, Bernhard
    Maintz, David
    Bunck, Alexander C.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2161 - 2170
  • [6] Matrix description of general motion correction applied to multishot images
    Batchelor, PG
    Atkinson, D
    Irarrazaval, P
    Hill, DLG
    Hajnal, J
    Larkman, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1273 - 1280
  • [7] Interleaved T1 and T2 Relaxation Time Mapping for Cardiac Applications
    Blume, Ulrike
    Lockie, Timothy
    Stehning, Christian
    Sinclair, Stephen
    Uribe, Sergio
    Razavi, Reza
    Schaeffter, Tobias
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 480 - 487
  • [8] Boyd S., 2010, FOUND TRENDS MACH LE, V3, P1, DOI DOI 10.1561/2200000016
  • [9] MR Fingerprinting with Simultaneous B1 Estimation
    Buonincontri, Guido
    Sawiak, Stephen J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1127 - 1135
  • [10] High-dimensionality undersampled patch-based reconstruction (HD-PROST) for accelerated multi-contrast MRI
    Bustin, Aurelien
    da Cruz, Gastao Lima
    Jaubert, Olivier
    Lopez, Karina
    Botnar, Rene M.
    Prieto, Claudia
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3705 - 3719