Impact of interfraction seroma collection on breast brachytherapy dosimetry - a mathematical model

被引:7
作者
Bhatt, Aashish [1 ]
Sowards, Keith [1 ]
Bhatt, Geetika [1 ]
Freeman, Andrew [2 ]
Dragun, Anthony [1 ]
机构
[1] Univ Louisville, Sch Med, Louisville, KY 40292 USA
[2] Marshall Univ, Sch Med, Huntington, WV USA
关键词
seroma; dosimetry; breast brachytherapy; contura catheter;
D O I
10.5114/jcb.2012.29366
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Balloon brachytherapy is a widely accepted modality for delivery of accelerated partial breast irradiation (APBI). Our hypothesis was that inter-fraction seroma collection around the balloon surface would have an adverse effect on dosimetry of the target. Material and methods: This is a dosimetric re-planning study using two volumetric models (30 cc and 45 cc) in a Contura (R) multi-lumen balloon (MLB) catheter. In a previously treated patient, two customized baseline plans were generated using multiple channels of the Contura (R) catheter prescribed to the Planning Target Volume Evaluation (PTV_Eval). Symmetric expansions of 1.0 mm (0-9 mm) increments around the balloon surface were performed to simulate a "Virtual Seroma" (VS) accumulation for both balloon volumes and plans were obtained for each expansion using Eclipse Brachy vision T. An analysis of these plans was then performed to evaluate the effect of seroma accumulation on dosimetric parameters of V100 and V90. Results: 20 plans were generated and analyzed (10 plans for each balloon volume), representing VS of 6.0-66.0 cc. There was a commensurate decrease in the dose delivered to the PTV_Eval V100 and V90 (as defined by the original treatment plan) with increasing VS accumulation leading to a sub-optimal coverage of the PTV_Eval. For 30 cc MLB catheter, V100 decreased by 1.4% and V90 decreased by 0.9% for every 1 cc of VS. For 45cc MLB catheter, V100 decreased by 1.3% and V90 decreased by 1.15% for every 1.0 cc accumulation of VS. Conclusions: Balloon catheter-tissue adherence ensures daily dose delivery to the planned PTV_Eval. Accumulation of seroma, hematoma or air between HDR fractions can significantly impact PTV_Eval dosimetry. Vacuum-port aspiration prior to delivery of each fraction, if available, should be considered to minimize the risk of geographic under dosing.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 29 条
  • [1] Accelerated partial breast irradiation as a part of breast conservation therapy
    Arthur, DW
    Vicini, FA
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (08) : 1726 - 1735
  • [2] The use of high-dose-rate brachytherapy alone after lumpectomy in patients with early-stage breast cancer treated with breast-conserving therapy
    Baglan, KL
    Martinez, AA
    Frazier, RC
    Kini, VR
    Kestin, LL
    Chen, PY
    Edmundson, G
    Mele, E
    Jaffray, D
    Vicini, FA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (04): : 1003 - 1011
  • [3] The study of cytokine dynamics at the operation site after mastectomy
    Chow, LWC
    Loo, WTY
    Yuen, KY
    Cheng, C
    [J]. WOUND REPAIR AND REGENERATION, 2003, 11 (05) : 326 - 330
  • [4] RANDOMIZED CLINICAL-TRIAL TO ASSESS THE EFFECTIVENESS OF BREAST IRRADIATION FOLLOWING LUMPECTOMY AND AXILLARY DISSECTION FOR NODE-NEGATIVE BREAST-CANCER
    CLARK, RM
    MCCULLOCH, PB
    LEVINE, MN
    LIPA, M
    WILKINSON, RH
    MAHONEY, LJ
    BASRUR, VR
    NAIR, BD
    MCDERMOT, RS
    WONG, CS
    CORBETT, PJ
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1992, 84 (09): : 683 - 689
  • [5] Persistent seroma after intraoperative placement of mammosite for accelerated partial breast irradiation: Incidence, pathologic anatomy, and contributing factors
    Evans, Suzanne B.
    Kaufman, Seth A.
    Price, Lori Lyn
    Cardarelli, Gene
    Dipetrillo, Thomas A.
    Wazer, David E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 333 - 339
  • [6] FAVERLY DRG, 1994, SEMIN DIAGN PATHOL, V11, P193
  • [7] Gonzalez Ernest A, 2003, Breast J, V9, P385, DOI 10.1046/j.1524-4741.2003.09504.x
  • [8] Interfractional dose variation due to seromas in radiotherapy of breast cancer
    Huh, SJ
    Han, Y
    Park, W
    Yang, JH
    [J]. MEDICAL DOSIMETRY, 2005, 30 (01) : 8 - 11
  • [9] Relationship between the morphological and biological characteristics of intraductal components accompanying invasive ductal breast carcinoma and patient age
    Imamura, H
    Haga, S
    Shimizu, T
    Watanabe, O
    Kinoshita, J
    Nagumo, H
    Kajiwara, T
    Aiba, M
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2000, 62 (03) : 177 - 184
  • [10] WHEN IS CT-BASED POSTOPERATIVE SEROMA MOST USEFUL TO PLAN PARTIAL BREAST RADIOTHERAPY? EVALUATION OF CLINICAL FACTORS AFFECTING SEROMA VOLUME AND CLARITY
    Kader, Hosam A.
    Truong, Pauline T.
    Pai, Rohit
    Panades, Miguel
    Jones, Stuart
    Ansbacher, Will
    Olivotto, Ivo A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1064 - 1069