Negative chemical ionization gas chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry and automated accurate mass data processing for determination of pesticides in fruit and vegetables

被引:19
作者
Besil, Natalia [1 ,2 ,3 ]
Ucles, Samanta [1 ]
Mezcua, Milagros [1 ]
Heinzen, Horacio [2 ,3 ]
Fernandez-Alba, Amadeo R. [1 ]
机构
[1] Univ Almeria, European Union Reference Lab Pesticide Residues F, Resticide Residue Res Grp, Dept Chem & Phys, La Canada De San Urbano 04120, Almeria, Spain
[2] Univ Republ, Dept Quim Del Litoral, Polo Agroalimentario & Agroind, Paysandu 60000, Uruguay
[3] Univ Republica, Fac Quim, Catedra Farmacognosia & Prod Nat, Montevideo 11800, Uruguay
关键词
Gas chromatography; Quadrupole time-of-flight mass spectrometry; Negative chemical ionization; High resolution; Pesticides; ORGANIC POLLUTANTS; IDENTIFICATION; MS;
D O I
10.1007/s00216-015-8514-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatography coupled to high resolution hybrid quadrupole time-of-flight mass spectrometry (GC-QTOF MS), operating in negative chemical ionization (NCI) mode and combining full scan with MSMS experiments using accurate mass analysis, has been explored for the automated determination of pesticide residues in fruit and vegetables. Seventy compounds were included in this approach where 50 % of them are not approved by the EU legislation. A global 76 % of the analytes could be identified at 1 mu g kg(-1). Recovery studies were developed at three concentration levels (1, 5, and 10 mu g kg(-1)). Seventy-seven percent of the detected pesticides at the lowest level yielded recoveries within the 70 %-120 % range, whereas 94 % could be quantified at 5 mu g kg(-1), and the 100 % were determined at 10 mu g kg(-1). Good repeatability, expressed as relative standard deviation (RSD < 20 %), was obtained for all compounds. The main drawback of the method was the limited dynamic range that was observed for some analytes that can be overcome either diluting the sample or lowering the injection volume. A home-made database was developed and applied to an automatic accurate mass data processing. Measured mass accuracies of the generated ions were mainly less than 5 ppm for at least one diagnostic ion. When only one ion was obtained in the single-stage NCI-MS, a representative product ion from MSMS experiments was used as identification criterion. A total of 30 real samples were analyzed and 67 % of the samples were positive for 12 different pesticides in the range 1.0-1321.3 mu g kg(-1).
引用
收藏
页码:6327 / 6343
页数:17
相关论文
共 18 条
[1]  
[Anonymous], 2013, SANCO/12571/2013
[2]  
Belmonte N, 2014, LCXGC EUROPE ADV GC
[3]   A sensitive and selective method for the determination of selected pesticides in fruit by gas chromatography/mass spectrometry with negative chemical ionization [J].
Belmonte Valles, N. ;
Retamal, M. ;
Mezcua, M. ;
Fernandez-Alba, A. R. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1264 :110-116
[4]   Screening and quantification of pesticide residues in fruits and vegetables making use of gas chromatography-quadrupole time-of-flight mass spectrometry with atmospheric pressure chemical ionization [J].
Cervera, M. I. ;
Portoles, T. ;
Lopez, F. J. ;
Beltran, J. ;
Hernandez, F. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (27) :6843-6855
[5]   Use of an accurate-mass database for the systematic identification of transformation products of organic contaminants in wastewater effluents [J].
del Mar Gomez-Ramos, Maria ;
Perez-Parada, Andres ;
Garcia-Reyes, Juan F. ;
Fernandez-Alba, Amadeo R. ;
Agueera, Ana .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (44) :8002-8012
[6]   Current use of high-resolution mass spectrometry in the environmental sciences [J].
Hernandez, F. ;
Sancho, J. V. ;
Ibanez, M. ;
Abad, E. ;
Portoles, T. ;
Mattioli, L. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (05) :1251-1264
[7]   Gas chromatography coupled to high-resolution time-of-flight mass spectrometry to analyze trace-level organic compounds in the environment, food safety and toxicology [J].
Hernandez, Felix ;
Portoles, Tania ;
Pitarch, Elena ;
Lopez, Francisco J. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (02) :388-400
[8]   Determination of polybrominated diphenyl ethers in human milk samples in the Czech Republic -: Comparative study of negative chemical ionisation mass spectrometry and time-of-flight high-resolution mass spectrometry [J].
Kazda, R ;
Hajslová, J ;
Poustka, J ;
Cajka, T .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :237-243
[9]   Determination of selected pesticides by GC with simultaneous detection by MS (NCI) and μ-ECD in fruit and vegetable matrices [J].
Martinez-Uroz, M. A. ;
Mezcua, M. ;
Valles, N. Belmonte ;
Fernandez-Alba, A. R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (03) :1365-1372
[10]   Assessment of gas chromatography time-of-flight accurate mass spectrometry for identification of volatile and semi-volatile compounds in honey [J].
Moniruzzaman, M. ;
Rodriguez, I. ;
Ramil, M. ;
Cela, R. ;
Sulaiman, S. A. ;
Gan, S. H. .
TALANTA, 2014, 129 :505-515