Intra-eye Visual Function Comparison With and Without a Central Hole Contact Lens-Based System: Potential Applications to ICL Design

被引:13
作者
Ferrer-Blasco, Teresa [1 ]
Garcia-Lazaro, Santiago [1 ]
Belda-Salmeron, Lurdes [1 ]
Albarran-Diego, Cesar [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, E-46100 Valencia, Spain
关键词
PHAKIC INTRAOCULAR-LENS; IMPLANTABLE COLLAMER LENS; 3-YEAR FOLLOW-UP; HIGH MYOPIA; CLINICAL-OUTCOMES; OPTICAL-QUALITY; MODERATE;
D O I
10.3928/1081597X-20130919-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the effects of a central hole contact lens-based design on visual performance and to compare it with the standard version of that same contact lens without the hole (non-hole scenario). METHODS: The visual performance of 10 myopic patients wearing either a central hole myopic contact lens or its corresponding standard version (non-hole contact lens) was assessed on the same eye. Monocular corrected distance visual acuity was measured under photopic conditions and monocular contrast sensitivity was measured under both photopic and mesopic conditions and higher-order ocular aberrations using Hartmann-Shack aberrometry. An in vitro optical analysis of both contact lenses was performed and a symptoms questionnaire was administered to the participants. RESULTS: No statistically significant differences in terms of corrected distance visual acuity were found: -0.091 and -0.098 logMAR for the hole and non-hole contact lenses, respectively (P > .05). Contrast sensitivity was comparable between lenses and no differences were found for specific spatial frequencies or a particular luminance level (P > .05). The hole contact lenses provided excellent outcomes, essentially equivalent to those of non-hole contact lenses, even in terms of subjective symptoms such as glare or halo. In vivo and in vitro optical quality analysis revealed no statistically significant differences between the hole and the non-hole contact lenses for either pupil size (P > .1). CONCLUSION: A contact lens having a central hole provides good visual and optical quality outcomes comparable to those yielded by the same lens without a hole. The results suggest that the impact of a central hole may be clinically negligible.
引用
收藏
页码:702 / 707
页数:6
相关论文
共 15 条
[1]   Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega Cueto, Luis ;
Belda-Salmeron, Lurdes ;
Madrid-Costa, David ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06) :915-921
[2]   Three-year follow-up of subjective vault following myopic implantable collamer lens implantation [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Abdelhamid, A. ;
Fernandes, Paulo ;
Jorge, Jorge ;
Montes-Mico, Robert .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (12) :1827-1835
[3]   In vitro power profiles of daily disposable contact lenses [J].
Belda-Salmeron, Lurdes ;
Madrid-Costa, David ;
Ferrer-Blasco, Teresa ;
Garcia-Lazaro, Santiago ;
Montes-Mico, Robert .
CONTACT LENS & ANTERIOR EYE, 2013, 36 (05) :247-252
[4]   Quality of Life in High Myopia before and after Implantable Collamer Lens Implantation [J].
Ieong, Alvin ;
Hau, Scott C. H. ;
Rubin, Gary S. ;
Allan, Bruce D. S. .
OPHTHALMOLOGY, 2010, 117 (12) :2295-2300
[5]  
Jewelewicz Daniel A., 1998, CLAO Journal, V24, P107
[6]   Four-Year Follow-up of Posterior Chamber Phakic Intraocular Lens Implantation for Moderate to High Myopia [J].
Kamiya, Kazutaka ;
Shimizu, Kimiya ;
Igarashi, Akihito ;
Hikita, Fumika ;
Komatsu, Mari .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (07) :845-850
[7]   Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation [J].
Kawamorita, Takushi ;
Uozato, Hiroshi ;
Shimizu, Kimiya .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (06) :935-939
[8]   Optical Quality Comparison of Conventional and Hole-Visian Implantable Col lamer Lens at Different Degrees of Decentering [J].
Perez-Vives, Cari ;
Ferrer-Blasco, Teresa ;
Madrid-Costa, David ;
Garcia-Lazaro, Santiago ;
Montes-Mico, Robert .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (01) :69-76
[9]   Optical quality of the Visian Implantable Collamer Lens for different refractive powers [J].
Perez-Vives, Cari ;
Dominguez-Vicent, Alberto ;
Ferrer-Blasco, Teresa ;
Pons, Alvaro M. ;
Montes-Mico, Robert .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (05) :1423-1429
[10]   Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator [J].
Perez-Vives, Cari ;
Ferrer-Blasco, Teresa ;
Dominguez-Vicent, Alberto ;
Garcia-Lazaro, Santiago ;
Montes-Mico, Robert .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (03) :499-507