Visualization of pigment distributions in paintings using synchrotron K-edge imaging

被引:33
作者
Krug, K
Dik, J
den Leeuw, M
Whitson, A
Tortora, J
Coan, P
Nemoz, C
Bravin, A
机构
[1] Delft Univ Technol, Dept Mat Sci & Engn, NL-2628 AL Delft, Netherlands
[2] Atelier Restorat & Res Paintings, The Hague, Netherlands
[3] L3 Commun, Woburn, MA 01801 USA
[4] JK Consulting, Sudbury, MA 01776 USA
[5] European Synchrotron Radiat Facil, F-38043 Grenoble, France
来源
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING | 2006年 / 83卷 / 02期
关键词
D O I
10.1007/s00339-006-3519-y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
X-ray radiography plays an important role in the study of artworks and archaeological artifacts. The internal structure of objects provides information on genesis, authenticity, painting technique, material condition and conservation history. Transmission radiography, however, does not provide information on the exact elemental composition of objects and heavy metal layers can shadow or obscure the ones including lighter elements. This paper presents the first application of synchrotron-based K-edge absorption imaging applied to paintings. Using highly monochromatic radiation, K-edge imaging is used to obtain elemental distribution images over large areas. Such elemental maps visualize the distribution of an individual pigment throughout the paint stratigraphy. This provides color information on hidden paint layers, which is of great relevance to art historians and painting conservators. The main advantage is the quick data acquisition time and the sensitivity to elements throughout the entire paint stratigraphy. The examination of a test painting is shown and further instrumental developments are discussed.
引用
收藏
页码:247 / 251
页数:5
相关论文
共 21 条
[1]   High-resolution blood-brain barrier permeability and blood volume imaging using quantitative synchrotron radiation computed tomography:: study on an F98 rat brain glioma [J].
Adam, JF ;
Nemoz, C ;
Bravin, A ;
Fiedler, S ;
Bayat, S ;
Monfraix, S ;
Berruyer, G ;
Charvet, AM ;
Le Bas, JF ;
Elleaume, H ;
Estève, F .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2005, 25 (02) :145-153
[2]  
[Anonymous], Z KUNSTTECHNOLOGIE K
[3]  
[Anonymous], STUD CONSERV, DOI DOI 10.2307/1505428
[4]  
BALDELLI P, 2004, EUR C XRAY SPECTR, P22
[5]   Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty [J].
Bertrand, B ;
Estève, F ;
Elleaume, H ;
Nemoz, C ;
Fiedler, S ;
Bravin, A ;
Berruyer, G ;
Brochard, T ;
Renier, M ;
Machecourt, J ;
Thomlinson, W ;
Le Bas, JF .
EUROPEAN HEART JOURNAL, 2005, 26 (13) :1284-1291
[6]   Cure of fisher rats bearing radioresistant F98 glioma treated with cis-platinum and irradiated with monochromatic synchrotron X-rays [J].
Biston, MC ;
Joubert, A ;
Adam, JF ;
Elleaume, H ;
Bohic, S ;
Charvet, AM ;
Estève, F ;
Foray, N ;
Balosso, J .
CANCER RESEARCH, 2004, 64 (07) :2317-2323
[7]  
Bridgman C.F., 1964, Stud. Conserv., V9, P135
[8]  
DIK J, 2004, INT WORKSH INT NOND, P45
[9]  
DIRVEN R, 2003, VERLOREN VONDSTEN
[10]   Instrumentation of the ESRF medical imaging facility [J].
Elleaume, H ;
Charvet, AM ;
Berkvens, P ;
Berruyer, G ;
Brochard, T ;
Dabin, Y ;
Dominguez, MC ;
Draperi, A ;
Fiedler, S ;
Goujon, G ;
Le Duc, G ;
Mattenet, M ;
Nemoz, C ;
Perez, M ;
Renier, M ;
Schulze, C ;
Spanne, P ;
Suortti, P ;
Thomlinson, W ;
Esteve, F ;
Bertrand, B ;
Le Bas, JF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :513-527