摘要
Positron emission tomography (PET) image quality is limited by patient motion. Emission data are blurred owing to cardiac and/or respiratory motion. Although spatial resolution is 4 mm for standard clinical whole-body PET scanners, the effective resolution can be as low as 1 cm owing to motion. Additionally, the deformation of attenuation medium causes image artifacts. Previously, gating has been used to "freeze" the motion, but led to significantly increased noise level. Simultaneous PET/magnetic resonance (MR) modality offers a new way to perform PET motion correction. MR can be used to measure 3-dimensional motion fields, which can then be incorporated into the iterative PET reconstruction to obtain motion-corrected PET images. In this report, we present MR imaging techniques to acquire dynamic images, a nonrigid image registration algorithm to extract motion fields from acquired MR images, and a PET reconstruction algorithm with motion correction. We also present results from both phantom and in vivo animal PET/MR studies. We demonstrate that MR-based PET motion correction using simultaneous PET/MR improves image quality and lesion detectability compared with gating and no motion correction. Semin Nucl Med 43:60-67 (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 53 条
[1]   Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction [J].
Alessio, Adam M. ;
Stearns, Charles W. ;
Tong, Shan ;
Ross, Steven G. ;
Kohlmyer, Steve ;
Ganin, Alex ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) :938-949
[2]   MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[3]   Motion Correction and Attenuation Correction for Respiratory Gated PET Images [J].
Bai, Wenjia ;
Brady, Michael .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) :351-365
[4]   Regularized B-spline deformable registration for respiratory motion correction in PET images [J].
Bai, Wenjia ;
Brady, Michael .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2719-2736
[5]   Joint Reconstruction of Image and Motion in Gated Positron Emission Tomography [J].
Blume, Moritz ;
Martinez-Moeller, Axel ;
Keil, Andreas ;
Navab, Nassir ;
Rafecas, Magdalena .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) :1892-1906
[6]  
Boucher L, 2004, J NUCL MED, V45, P214
[7]  
Brasse D, 2005, J NUCL MED, V46, P859
[8]   List Mode-Driven Cardiac and Respiratory Gating in PET [J].
Buether, Florian ;
Dawood, Mohammad ;
Stegger, Lars ;
Wuebbeling, Frank ;
Schaefers, Michael ;
Schober, Otmar ;
Schaefers, Klaus P. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (05) :674-681
[9]   An accurate method for correction of head movement in PET [J].
Bühler, P ;
Just, U ;
Will, E ;
Kotzerke, J ;
van den Hoff, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) :1176-1185
[10]  
Burden R, 1978, NUMERICAL ANAL, P34