Determination of penumbral widths from ion chamber measurements

被引:16
作者
Herrup, D [1 ]
Chu, J
Cheung, H
Pankuch, M
机构
[1] Rush Univ, Med Ctr, Chicago, IL 60614 USA
[2] Lutheran Gen Hosp, Park Ridge, IL 60068 USA
关键词
D O I
10.1118/1.2128086
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have investigated methods of reconstructing beam profiles in the penumbral region using a set of axially symmetric chambers, differing only in the detector radius. In principal, the transfer functions, or kernels, of such chambers should be functions of radius only. Three chambers of radii 0.297, 0.556, and 0.714 cm have been used. The transfer functions of the chambers can be determined by deconvolving the profiles measured with each detector with the PPMC profile. The results indicate that the transfer functions can be parametrized accurately as a Gaussian cutoff at 1.75 < r >. with < r > the average radius of the chamber. Deconvolution of the measured profiles with the transfer functions yields a profile that agrees with the PPMC profile to +/- 0.5 min over the 20-90% penumbra. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:3636 / 3640
页数:5
相关论文
共 12 条
[1]  
[Anonymous], 2003, PHYS RAD THERAPY
[2]   Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams [J].
Bednarz, G ;
Huq, MS ;
Rosenow, UF .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20) :3643-3649
[3]   The effect of detector size to the broadening of the penumbra - A computer simulated study [J].
Chang, KS ;
Yin, FF ;
Nie, KW .
MEDICAL PHYSICS, 1996, 23 (08) :1407-1411
[4]  
CHATLAND P, 1998, MED PHYS, V25, P152
[5]   EXTRACTION OF PENCIL BEAM KERNELS BY THE DECONVOLUTION METHOD [J].
CHUI, CS ;
MOHAN, R .
MEDICAL PHYSICS, 1988, 15 (02) :138-144
[6]   ANALYSIS OF PHYSICAL PARAMETERS ASSOCIATED WITH THE MEASUREMENT OF HIGH-ENERGY X-RAY PENUMBRA [J].
DAWSON, DJ ;
HARPER, JM ;
AKINRADEWO, AC .
MEDICAL PHYSICS, 1984, 11 (04) :491-497
[7]   Experimental determination of the convolution kernel for the study of the spatial response of a detector [J].
Garcia-Vicente, F ;
Delgado, JM ;
Peraza, C .
MEDICAL PHYSICS, 1998, 25 (02) :202-207
[8]  
Gonzalez R.C., 1992, DIGITAL IMAGE PROCES
[9]   DECONVOLUTION OF DETECTOR SIZE EFFECT FOR SMALL-FIELD MEASUREMENT [J].
HIGGINS, PD ;
SIBATA, CH ;
SISKIND, L ;
SOHN, JW .
MEDICAL PHYSICS, 1995, 22 (10) :1663-1666
[10]   The volume effect of detectors in the dosimetry of small fields used in IMRT [J].
Laub, WU ;
Wong, T .
MEDICAL PHYSICS, 2003, 30 (03) :341-347