Progress on the Design and Development of the Continuous-Flow Total Artificial Heart

被引:35
|
作者
Kobayashi, Mariko [1 ]
Horvath, David J. [1 ]
Mielke, Nicole [1 ]
Shiose, Akira [1 ]
Kuban, Barry [1 ]
Goodin, Mark [2 ]
Fukamachi, Kiyotaka [1 ]
Golding, Leonard A. R. [1 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
[2] SimuTech Grp Inc, Hudson, OH USA
基金
美国国家卫生研究院;
关键词
Continuous flow; Artificial heart; Hemolysis; Computational fluid dynamics; REPLACEMENT; TRANSPLANTATION; EXPERIENCE; FAILURE; SYSTEM; BRIDGE;
D O I
10.1111/j.1525-1594.2012.01489.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cleveland Clinic's continuous-flow total artificial heart has one motor and one rotating assembly supported by a hydrodynamic bearing. The right hydraulic output is self regulated by passive axial movement of the rotating assembly to balance itself with the left output. The purpose of this article is to present progress in four areas of development: the automatic speed control system, self-regulation to balance right/left inlet pressures and flows, hemolysis testing using calf blood, and coupled electromagnetics (EMAG) and computational fluid dynamics (CFD) analysis. The relationships between functions of motor power and speed, systemic flow, and systemic vascular resistance (SVR) were used for the sensorless speed control algorithm and demonstrated close correlations. Based on those empirical relationships, systemic flow and SVR were calculated in the system module and showed good correlation with measured pump flow and SVR. The automatic system adjusted the pump's speed to obtain the target flow in response to the calculated SVR. Atrial pressure difference (left minus right atrial pressure) was maintained within +/- 10 mm Hg for a wide range of SVR/pulmonary vascular resistance ratios, demonstrating a wide margin of self-regulation under fixed-speed mode and 25% sinusoidally modulated speed mode. Hemolysis test results indicated acceptable values (normalized index of hemolysis <0.01 mg/dL). The coupled EMAG/CFD model was validated for use in further device development.
引用
收藏
页码:705 / 713
页数:9
相关论文
共 50 条
  • [1] Development of Continuous-Flow Total Artificial Heart for Use in Infants
    Karimov, J. H.
    Polakowski, A.
    Horvath, D.
    Byram, N.
    Kado, Y.
    Miyamoto, T.
    Ahmad, M.
    Najm, H.
    Stewart, R.
    Saarel, E.
    Kuban, B.
    Fukamachi, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S482 - S482
  • [2] Artificial pulse with a continuous-flow total artificial heart
    Khalil, H. A.
    Kerr, D. T.
    Schusterman, M. A., II
    Frazier, O. H.
    Radovancevic, B.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S157 - S158
  • [3] Hybrid Continuous-Flow Total Artificial Heart
    Fox, Carson
    Chopski, Steven
    Murad, Nohra
    Allaire, Paul
    Mentzer, Robert, Jr.
    Rossano, Joseph
    Arabia, Francisco
    Throckmorton, Amy
    ARTIFICIAL ORGANS, 2018, 42 (05) : 500 - 509
  • [4] Cleveland Clinic Continuous-Flow Total Artificial Heart: Progress Report and Technology Update
    Kuroda, Taiyo
    Miyagi, Chihiro
    Polakowski, Anthony R.
    Flick, Christine R.
    Kuban, Barry D.
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    ASAIO JOURNAL, 2024, 70 (02) : 116 - 123
  • [5] New continuous-flow total artificial heart and vascular permeability
    Feng, Jun
    Cohn, William E.
    Parnis, Steven M.
    Sodha, Neel R.
    Clements, Richard T.
    Sellke, Nicholas
    Frazier, O. Howard
    Sellke, Frank W.
    JOURNAL OF SURGICAL RESEARCH, 2015, 199 (02) : 296 - 305
  • [6] Early in vivo experience with the pediatric continuous-flow total artificial heart
    Karimov, Jamshid H.
    Horvath, David J.
    Byram, Nicole
    Sunagawa, Gengo
    Kuban, Barry D.
    Gao, Shengqiang
    Dessoffy, Raymond
    Fukamachi, Kiyotaka
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (08): : 1029 - 1034
  • [7] Initial Fitting Study of a Pediatric Continuous-Flow Total Artificial Heart
    Miyagi, C.
    Karimov, J. H.
    Kado, Y.
    Ray, D.
    Polakowski, T.
    Ahmad, M.
    Karamlow, T.
    Najm, H. K.
    Fukamachi, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S173 - S174
  • [8] Initial in vitro testing of a paediatric continuous-flow total artificial heart
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    Horvath, David J.
    Sunagawa, Gengo
    Byram, Nicole A.
    Kuban, Barry D.
    Moazami, Nader
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 26 (06) : 897 - 901
  • [9] Initial In Vitro Testing of a Pediatric Continuous-Flow Total Artificial Heart
    Fukamachi, K.
    Horvath, D. J.
    Karimov, J. H.
    Sunagawa, G.
    Byram, N.
    Kuban, B. D.
    Gao, S.
    Dessoffy, R.
    Moazami, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S164 - S164
  • [10] An innovative, sensorless, pulsatile, continuous-flow total artificial heart: Device design and initial in vitro study
    Fukamachi, Kiyotaka
    Horvath, David J.
    Massietto, Alex L.
    Fumoto, Hideyuki
    Horai, Tetsuya
    Rao, Santosh
    Golding, Leonard A. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (01): : 13 - 20