Endovascular stent-grafting via the aortic arch for distal aortic arch aneurysm: an alternative to endovascular stent-grafting

被引:20
|
作者
Orihashi, K [1 ]
Sueda, T [1 ]
Watari, M [1 ]
Okada, K [1 ]
Ishii, O [1 ]
Matsuura, Y [1 ]
机构
[1] Hiroshima Univ, Sch Med, Dept Surg 1, Minami Ku, Hiroshima 7348551, Japan
关键词
aortic aneurysm; stent grafting; aortic dissection; transesophageal echocardiography;
D O I
10.1016/S1010-7940(01)00909-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We have experienced transaortic stent-grafting for treating distal arch aneurysm or type B dissection. This paper is to mainly report the surgical aspect of these procedures. Methods: Fifteen patients underwent this surgery, including 12 men and three women ranging from 47 to 83 years. Twelve had aneurysms and three aortic dissection. Concomitant surgery was necessary in seven patients (coronary artery bypass grafting in five, tricuspid annuloplasty in one, and replacement of ascending aorta and/or total arch replacement in three cases). A stent graft (Gianturco Z-stent and Intervascular prosthesis) was loaded in a 30-F sheath catheter. Under circulatory arrest, selective cerebral perfusion was established, and the sheath catheter was inserted through aortotomy into descending aorta and the stent graft was deployed at an appropriate level. The proximal end of graft was sutured to the aorta just distal to the left subclavian artery with inclusion method at the posterior wall. Concomitant surgery was done during cooling or rewarming period. TEE was utilized to visualize every endovascular manipulation to avoid unintended intimal injury or misplacement of graft and to assess the surgical results in the operative theater. Results: Aneurysm was successfully excluded except in one patient who had a proximal endoleak and distal endoleak due to underestimation of aortic diameter. There was one operative mortality caused by cerebral infarction, possibly due to debris from femoral arterial cannulation. In the remaining patients, there was no enlargement of residual aneurysm. The excluded aneurysmal sac gradually regressed and disappeared within 2 years in five patients and the thrombosed false lumen completely shrunk within I year in two patients. One patient had paraplegia, possibly because the graft was intentionally advanced deeply to cover the thick and fragile atheromatous layer in order to avoid destruction of the atheroma by an expanded graft. Conclusions: Endovascular stent graft via the aortic arch is an acceptable treatment for distal arch aneurysms close to or involving left subclavian artery or type B dissections, especially for those cases requiring other cardiac procedures. It can lead to regression and disappearance of aneurysm or dissection in the mid-term follow-up. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:973 / 978
页数:6
相关论文
共 50 条
  • [31] Continued aortic aneurysmal expansion after thoracic endovascular stent-grafting
    Bakaeen, Faisal G.
    Coselli, Joseph S.
    LeMaire, Scott A.
    Huh, Joseph
    ANNALS OF THORACIC SURGERY, 2007, 84 (03): : 1007 - 1008
  • [32] Endoleaks After Endovascular Aortic Stent-Grafting: Impact, Diagnosis, and Management
    Gleason, Thomas G.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2009, 21 (04) : 363 - 372
  • [33] Endovascular stent-grafting for traumatic aortic aneurysms with the use of a fenestrated stent-graft
    Sueda, T
    Orihashi, K
    Watari, M
    Okada, K
    Ishii, O
    Naito, A
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (01): : 144 - 146
  • [34] VISUALIZING CHANGES IN VESSEL WALL DYNAMICS DUE TO STENT-GRAFTING IN THE AORTIC ARCH
    Schwartz, Ernst
    Holfeld, Johannes
    Czerny, Martin
    Langs, Georg
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 788 - 791
  • [35] A case report of blunt aortic arch injury treated by immediate stent-grafting
    Kurimoto, Y
    Morishita, K
    Kawaharada, N
    Fukada, J
    Asai, Y
    Abe, T
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 26 (04) : 445 - 447
  • [36] Fate of aneurysms of the distal arch and proximal descending thoracic aorta after transaortic endovascular stent-grafting
    Sueda, T
    Orihashi, K
    Okada, K
    Sugawara, Y
    Imai, K
    Kochi, K
    ANNALS OF THORACIC SURGERY, 2003, 76 (01): : 84 - 89
  • [37] Endovascular aortic repair immediately after open stent-grafting: collapse of the endograft
    Motomatsu, Yuma
    Oishi, Yasuhisa
    Matsunaga, Shogo
    Tominaga, Ryuji
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (02) : 390 - 392
  • [38] Endovascular stent-grafting for recurrent aneurysm in Behcet's disease
    Watanabe, H
    Oda, H
    Yoshida, TS
    Yamaura, M
    Takahashi, K
    Miida, T
    Takahashi, N
    Nakazawa, S
    Kanazawa, H
    Higuma, N
    Aizawa, Y
    INTERNATIONAL HEART JOURNAL, 2005, 46 (04) : 745 - 749
  • [39] Fenestrated and branched stent-grafting after previous open or endovascular aortic surgery
    Katsargyris, A.
    Oikonomou, K.
    Spinelli, D.
    Houthoofd, S.
    Verhoeven, E. L. G.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2014, 55 (02): : 95 - 103
  • [40] Shrinkage of excluded aneurysmal spaces: The excellent results of endovascular stent grafting through the aortic arch for distal arch aneurysm
    Watari, M
    Sueda, T
    Ishii, O
    Imai, K
    Hidenori, S
    Sakai, H
    Wada, H
    Okada, K
    Orihashi, K
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (04): : 829 - 832