Thermographic and histological evaluation of laser skin resurfacing scans

被引:11
作者
Choi, B [1 ]
Chan, EK
Barton, JK
Thomsen, SL
Welch, AJ
机构
[1] Univ Texas, Biomed Engn Laser Lab, Austin, TX 78712 USA
[2] Indigo Med Inc, Cincinnati, OH 45242 USA
[3] Univ Arizona, Biomed Engn Program, Tucson, AZ 85721 USA
[4] Univ Texas, MD Anderson Canc Ctr, Dept Anat Pathol, Houston, TX USA
关键词
animals; biomedical infrared imaging; laser ablation; pulsed lasers; skin; temperature measurement;
D O I
10.1109/2944.796338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In general, ablative laser skin resurfacing procedures have shown good short-term efficacy. However, the mechanisms underlying laser skin resurfacing remain poorly understood. We performed a quantitative study to investigate the thermal response of skin to CO2 laser irradiation. Raster scans were performed on an in vivo rat model and radiometric surface temperatures measured using a thermal camera, Temperatures approaching 400 degrees C were measured during the scans and remained above the initial skin temperature for durations longer than ten seconds. Analysis of histology sections show ed that the epidermis remained partially intact after three passes. To explain the observed trends in the temperature response and histology, the dynamics of optical and thermal parameters were investigated. Water vaporization played a key role in governing the response of the skin to subsequent laser passes. Char formation and pulse stacking altered the thermal effects.
引用
收藏
页码:1116 / 1126
页数:11
相关论文
共 46 条
[1]   Comparison of two high-energy, pulsed carbon dioxide lasers in the treatment of periorbital rhytides [J].
Alster, TS .
DERMATOLOGIC SURGERY, 1996, 22 (06) :541-545
[2]   Histology of high-energy pulsed CO2 laser resurfacing [J].
Alster, TS ;
Kauvar, ANB ;
Geronemus, RG .
SEMINARS IN CUTANEOUS MEDICINE AND SURGERY, 1996, 15 (03) :189-193
[3]   SELECTIVE PHOTOTHERMOLYSIS - PRECISE MICROSURGERY BY SELECTIVE ABSORPTION OF PULSED RADIATION [J].
ANDERSON, RR ;
PARRISH, JA .
SCIENCE, 1983, 220 (4596) :524-527
[4]   The ultrapulse carbon dioxide laser with computer pattern generator automatic scanner for facial cosmetic surgery and resurfacing [J].
Apfelberg, DB .
ANNALS OF PLASTIC SURGERY, 1996, 36 (05) :522-529
[5]  
Biesman BS, 1996, OPHTHALMIC SURG LAS, V27, P685
[6]   TEMPERATURE RESPONSE OF BIOLOGICAL-MATERIALS TO PULSED NON-ABLATIVE CO2-LASER IRRADIATION [J].
BRUGMANS, MJP ;
KEMPER, J ;
GIJSBERS, GHM ;
VANDERMEULEN, FW ;
VANGEMERT, MJC .
LASERS IN SURGERY AND MEDICINE, 1991, 11 (06) :587-594
[7]  
Carslaw H. S., 1959, CONDUCTION HEAT SOLI
[8]  
Chernoff G, 1995, J Clin Laser Med Surg, V13, P97
[9]  
Choi B, 1998, LASER SURG MED, V23, P185, DOI 10.1002/(SICI)1096-9101(1998)23:4<185::AID-LSM1>3.0.CO
[10]  
2-7