Tumor motion and deformation during external radiotherapy of bladder cancer

被引:71
作者
Lotz, HT
Pos, FJ
Hulshof, MCCM
Van Herk, M
Lebesque, JV
Duppen, JC
Remeijer, P
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiat Oncol, NL-1105 AZ Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 05期
关键词
bladder cancer; bladder shape; tumor motion; image-guided radiotherapy;
D O I
10.1016/j.ijrobp.2005.12.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: First, to quantify bladder-tumor motion in 3 dimensions during a 4-week to 5-week course of external radiotherapy. Second, to relate the motion to the tumor location on the bladder wall. Third, to extensively evaluate gross tumor volume (GTV) shape and volume changes during the course of the treatment. Methods and Materials: Multiple repeat computed tomography (CT) images were obtained for 21 bladder cancer patients. These scans were matched to the rigid bony anatomy. For each patient, the main direction and magnitude of the tumor movement was determined by use of principle-component analysis. To study GTV shape changes, all GTVs were registered to the GTV in the planning CT scan, and the residual shape errors were determined by measurement of edge variations perpendicular to the median surface. Results: Gross tumor volume translations were largest in cranial-caudal and anterior-posterior direction (SD, 0.1 to similar to 0.9 cm). The translations were strongly correlated with the tumor location on the bladder wall. The average value of the local standard deviations of the GTV shape ranged from 0.1 to approximately 0.35 cm. Conclusions: Despite large differences in bladder filling, variations in GTV shape were small compared with variations in GTV position. Geometric uncertainties in the GTV position depended strongly on the tumor location on the bladder wall. (c) 2006 Elsevier Inc.
引用
收藏
页码:1551 / 1558
页数:8
相关论文
共 23 条
  • [1] Automatic registration of the prostate for computed-tomography-guided radiotherapy
    Court, LE
    Dong, L
    [J]. MEDICAL PHYSICS, 2003, 30 (10) : 2750 - 2757
  • [2] Impact of changes in bladder and rectal filling volume on organ motion and dose distribution of the bladder in radiotherapy for urinary bladder cancer
    Fokdal, L
    Honoré, H
    Hoyer, M
    Meldgaard, P
    Fode, K
    von der Maase, H
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02): : 436 - 444
  • [3] Harris S J, 1998, Clin Oncol (R Coll Radiol), V10, P262, DOI 10.1016/S0936-6555(98)80014-9
  • [4] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [5] A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
    Jaffray, DA
    Drake, DG
    Moreau, M
    Martinez, AA
    Wong, JW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03): : 773 - 789
  • [6] Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer
    Lebesque, JV
    Bruce, AM
    Kroes, APG
    Touw, A
    Shouman, T
    VanHerk, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1109 - 1119
  • [7] Lorensen WE, 1987, COMPUT GRAPH, DOI 10.1145/37401.37422
  • [8] Reproducibility of the bladder shape and bladder shape changes during filling
    Lotz, HT
    van Herk, M
    Betgen, A
    Pos, F
    Lebesque, JV
    Remeijer, P
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2590 - 2597
  • [9] A model to predict bladder shapes from changes in bladder and rectal filling
    Lotz, HT
    Remeijer, P
    van Herk, M
    Lebesque, JV
    de Bois, JA
    Zijp, LJ
    Moonen, LM
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1415 - 1423
  • [10] Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer
    Meijer, GJ
    Rasch, C
    Remeijer, P
    Lebesque, JV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05): : 1277 - 1287