Dosimetric comparison between intra-cavitary breast brachytherapy techniques for accelerated partial breast irradiation and a novel stereotactic radiotherapy device for breast cancer: GammaPodTM

被引:12
作者
Oden, Jakob [1 ]
Toma-Dasu, Iuliana [2 ,3 ]
Yu, Cedric X. [4 ,5 ]
Feigenberg, Steven J. [5 ]
Regine, William F. [5 ]
Mutaf, Yildirim D. [5 ]
机构
[1] Karolinska Univ Hosp, Dept Med Phys, Stockholm, Sweden
[2] Stockholm Univ, S-10691 Stockholm, Sweden
[3] Karolinska Inst, Stockholm, Sweden
[4] Xcision Med Syst LLC, Columbia, MD USA
[5] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
CONTURA MULTILUMEN BALLOON; MAMMOSITE; MULTICATHETER; TOXICITY; CATHETER; SKIN;
D O I
10.1088/0031-9155/58/13/4409
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The GammaPod (TM) device, manufactured by Xcision Medical Systems, is a novel stereotactic breast irradiation device. It consists of a hemispherical source carrier containing 36 Cobalt-60 sources, a tungsten collimator with two built-in collimation sizes, a dynamically controlled patient support table and a breast immobilization cup also functioning as the stereotactic frame for the patient. The dosimetric output of the GammaPod (TM) was modelled using a Monte Carlo based treatment planning system. For the comparison, three-dimensional (3D) models of commonly used intra-cavitary breast brachytherapy techniques utilizing single lumen and multi-lumen balloon as well as peripheral catheter multi-lumen implant devices were created and corresponding 3D dose calculations were performed using the American Association of Physicists in Medicine Task Group-43 formalism. Dose distributions for clinically relevant target volumes were optimized using dosimetric goals set forth in the National Surgical Adjuvant Breast and Bowel Project Protocol B-39. For clinical scenarios assuming similar target sizes and proximity to critical organs, dose coverage, dose fall-off profiles beyond the target and skin doses at given distances beyond the target were calculated for GammaPod (TM) and compared with the doses achievable by the brachytherapy techniques. The dosimetric goals within the protocol guidelines were fulfilled for all target sizes and irradiation techniques. For central targets, at small distances from the target edge (up to approximately 1 cm) the brachytherapy techniques generally have a steeper dose fall-off gradient compared to GammaPod (TM) and at longer distances (more than about 1 cm) the relation is generally observed to be opposite. For targets close to the skin, the relative skin doses were considerably lower for GammaPod (TM) than for any of the brachytherapy techniques. In conclusion, GammaPod (TM) allows adequate and more uniform dose coverage to centrally and peripherally located targets with an acceptable dose fall-off and lower relative skin dose than the brachytherapy techniques considered in this study.
引用
收藏
页码:4409 / 4421
页数:13
相关论文
共 21 条
  • [1] DIFFERENCES IN PATTERNS OF FAILURE IN PATIENTS TREATED WITH ACCELERATED PARTIAL BREAST IRRADIATION VERSUS WHOLE-BREAST IRRADIATION: A MATCHED-PAIR ANALYSIS WITH 10-YEAR FOLLOW-UP
    Antonucci, J. Vito
    Wallace, Michelle
    Goldstein, Neal S.
    Kestin, Larry
    Chen, Peter
    Benitez, Pamela
    Dekhne, Nayana
    Martinez, Alvaro
    Vicini, Frank
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02): : 447 - 452
  • [2] IMPROVEMENTS IN CRITICAL DOSIMETRIC ENDPOINTS USING THE CONTURA MULTILUMEN BALLOON BREAST BRACHYTHERAPY CATHETER TO DELIVER ACCELERATED PARTIAL BREAST IRRADIATION: PRELIMINARY DOSIMETRIC FINDINGS OF A PHASE IV TRIAL
    Arthur, Douglas W.
    Vicini, Frank A.
    Todor, Dorin A.
    Julian, Thomas B.
    Lyden, Maureen R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01): : 26 - 33
  • [3] Accelerated partial breast irradiation as a part of breast conservation therapy
    Arthur, DW
    Vicini, FA
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (08) : 1726 - 1735
  • [4] A COMPARISON OF SKIN AND CHEST WALL DOSE DELIVERED WITH MULTICATHETER, CONTURA MULTILUMEN BALLOON, AND MAMMOSITE BREAST BRACHYTHERAPY
    Cuttino, Laurie W.
    Todor, Dorin
    Rosu, Mihaela
    Arthur, Douglas W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01): : 34 - 38
  • [5] Persistent seroma after intraoperative placement of mammosite for accelerated partial breast irradiation: Incidence, pathologic anatomy, and contributing factors
    Evans, Suzanne B.
    Kaufman, Seth A.
    Price, Lori Lyn
    Cardarelli, Gene
    Dipetrillo, Thomas A.
    Wazer, David E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 333 - 339
  • [6] Development of a Stereotactic Body Radiation Therapy (SBRT) System Dedicated to the Treatment of Early Stage Breast Cancer: The Gammapod
    Feigenberg, S. J.
    Yu, C. X.
    Regine, W. F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S208 - S208
  • [7] Dosimetry evaluation of SAVI-based HDR brachytherapy for partial breast irradiation
    Manoharan, Sivasubramanian R.
    Rodriguez, R. Rodney
    Bobba, Vidya S.
    Chandrashekar, Mukka
    [J]. JOURNAL OF MEDICAL PHYSICS, 2010, 35 (03) : 131 - 136
  • [8] THE DOSIMETRIC ADVANTAGE OF STEREOTACTIC RADIOTHERAPY IN PARTIAL BREAST IRRADIATION: A COMPARATIVE ANALYSIS
    Mutaf, Y.
    Nichols, E.
    Yu, C.
    Prado, K.
    Feigenberg, S.
    Yi, B.
    D'Souza, W.
    Regine, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S572 - S572
  • [9] DOSIMETRIC CHARACTERIZATION OF A NOVEL STEREOTACTIC RADIOTHERAPY DEVICE FOR BREAST CANCER
    Mutaf, Y.
    Yu, C.
    Zhang, J.
    Prado, K.
    Feigenberg, S.
    Yi, B.
    D'Souza, W.
    Regine, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S160 - S161
  • [10] Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod™
    Mutaf, Yildirim D.
    Zhang, Jin
    Yu, Cedric X.
    Yi, Byong Yong
    Prado, Karl
    D'Souza, Warren D.
    Regine, William F.
    Feigenberg, Steven J.
    [J]. MEDICAL PHYSICS, 2013, 40 (04)