Coronary flow velocity reserve measurement in three major coronary arteries using transthoracic doppler echocardiography

被引:26
作者
Murata, E
Hozumi, T
Matsumura, Y
Fujimoto, K
Sugioka, K
Takemoto, Y
Watanabe, H
Yamagishi, H
Yoshiyama, M
Iwao, H
Yoshikawa, J
机构
[1] Osaka City Univ, Sch Med, Dept Internal Med & Cardiol, Abeno Ku, Osaka 5458585, Japan
[2] Osaka City Univ, Sch Med, Dept Pharmacol, Osaka 5458585, Japan
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2006年 / 23卷 / 04期
关键词
coronary flow velocity reserve; myocardial ischemia; transthoracic Doppler echocardiography;
D O I
10.1111/j.1540-8175.2006.00206.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Measurement of the coronary flow velocity reserve (CFVR) by transthoracic Doppler echocardiography (TTDE) has been reported to be useful for the noninvasive assessment of significant coronary artery stenosis or myocardial ischemia. The purpose of this study was to evaluate the value of this method in three major coronary arteries for detecting myocardial ischemia in the clinical setting. Methods: We studied 89 consecutive patients who were referred to our outpatient clinic because of chest pain. We measured CFVR using TTDE in three major coronary arteries. We defined CFVR < 2.0 in at least one vessel as being positive for myocardial ischemia. The accuracy of CFVR measurements for detecting myocardial ischemia was determined in comparison with exercise thallium-201 (Tl-201) single photon emission computed tomography (SPECT) as a reference standard. Results: CFVR in at least one vessel was successfully measured in 87 of 89 patients (98%). The sensitivity and specificity of CFVR < 2.0 in at least one coronary vessel, in any of the coronary territories, was 86% and 89%, respectively. In terms of assessing myocardial ischemia in each coronary artery territory, the agreement between CFVR < 2.0 and Tl-201 SPECT for the left anterior descending coronary artery, the posterior descending coronary artery, and the left circumflex coronary artery territories was 95%, 81%, and 73%, respectively. Conclusion: Noninvasive CFVR measurement by TTDE may be useful for detecting myocardial ischemia, as well as for identifying ischemic territories in the clinical setting.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 21 条
[1]   Coronary Vasodilator Reserve in Untreated and Treated Hypertensive Patients With and Without Left Ventricular Hypertrophy [J].
Antony, Isabelle ;
Nitenberg, Alain ;
Foult, Jean-Marc ;
Aptecar, Eduardo .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :514-520
[2]   TL-201 MYOCARDIAL PERFUSION IMAGING AT REST AND DURING EXERCISE - COMPARATIVE SENSITIVITY TO ELECTROCARDIOGRAPHY IN CORONARY-ARTERY DISEASE [J].
BAILEY, IK ;
GRIFFITH, LSC ;
ROULEAU, J ;
STRAUSS, HW ;
PITT, B .
CIRCULATION, 1977, 55 (01) :79-87
[3]   TL-201 MYOCARDIAL PERFUSION SCINTIGRAPHY FOR CLINICAL CLARIFICATION OF NORMAL, ABNORMAL AND EQUIVOCAL ELECTROCARDIOGRAPHIC STRESS TESTS [J].
BOTVINICK, EH ;
TARADASH, MR ;
SHAMES, DM ;
PARMLEY, WW .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (01) :43-51
[4]   Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine - A noninvasive, rapid and effective method for coronary flow reserve assessment [J].
Caiati, C ;
Zedda, N ;
Montaldo, C ;
Montisci, R ;
Iliceto, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (01) :122-130
[5]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[6]   Physiologic assessment of coronary artery stenosis by coronary flow reserve measurements with transthoracic Doppler echocardiography: Comparison with exercise thallium-201 single-photon emission computed tomography [J].
Daimon, M ;
Watanabe, H ;
Yamagishi, H ;
Muro, T ;
Akioka, K ;
Hirata, K ;
Takeuchi, K ;
Yoshikawa, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1310-1315
[7]  
Fujimoto Kohei, 2004, J Cardiol, V43, P109
[8]   Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography [J].
Hozumi, T ;
Yoshida, K ;
Ogata, Y ;
Akasaka, T ;
Asami, Y ;
Takagi, T ;
Morioka, S .
CIRCULATION, 1998, 97 (16) :1557-1562
[9]   Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography - Comparison with invasive technique [J].
Hozumi, T ;
Yoshida, K ;
Akasaka, T ;
Asami, Y ;
Ogata, Y ;
Takagi, T ;
Kaji, S ;
Kawamoto, T ;
Ueda, Y ;
Morioka, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1251-1259
[10]   Change in coronary flow reserve on transthoracic Doppler echocardiography after a single high-fat meal in young healthy men [J].
Hozumi, T ;
Eisenberg, M ;
Sugioka, K ;
Kokkirala, AR ;
Watanabe, H ;
Teragaki, M ;
Yoshikawa, J ;
Homma, S .
ANNALS OF INTERNAL MEDICINE, 2002, 136 (07) :523-528