Primary stability of a press-fit cup in combination with impaction grafting in an acetabular defect model

被引:0
作者
Schierjott, Ronja A. [1 ,2 ]
Hettich, Georg [1 ]
Baxmann, Marc [1 ]
Morosato, Federico [3 ]
Cristofolini, Luca [3 ]
Grupp, Thomas M. [1 ,2 ]
机构
[1] Aesculap AG, Res & Dev Dept, Tuttlingen, Germany
[2] Ludwig Maximilians Univ Munchen, Dept Orthopaed Surg Phys Med & Rehabil, Campus Grosshadern, Munich, Germany
[3] Alma Mater Studiorum Univ Bologna, Dept Ind Engn, Bologna, Italy
关键词
acetabular bone defect model; impaction grafting; optical measurement; press-fit cup; primary stability; synthetic bone graft substitute; MORSELLIZED BONE-GRAFTS; TOTAL HIP-ARTHROPLASTY; INITIAL STABILITY; CEMENTED CUPS; REVISION; RECONSTRUCTION; PARTICLES; SURVIVORSHIP; REPLACEMENT; FIXATION;
D O I
10.1002/jor.24810
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objectives of this study were to (a) assess primary stability of a press-fit cup in a simplified acetabular defect model, filled with compacted cancellous bone chips, and (b) to compare the results with primary stability of a press-fit cup combined with two different types of bone graft substitute in the same defect model. A previously developed acetabular test model made of polyurethane foam was used, in which a mainly medial contained defect was implemented. Three test groups (N = 6 each) were prepared: Cancellous bone chips (bone chips), tricalciumphosphate tetrapods + collagen matrix (tetrapods + coll), bioactive glass S53P4 + polyethylene glycol-glycerol matrix (b.a.glass + PEG). Each material was compacted into the acetabulum and a press-fit cup was implanted. The specimens were loaded dynamically in the direction of the maximum resultant force during level walking. Relative motion between cup and test model was assessed with an optical measurement system. At the last load step (3000 N), inducible displacement was highest for bone chips with median [25th percentile; 75th percentile] value of 113 [110; 114] mu m and lowest forb.a.glass + PEGwith 91 [89; 93] mu m. Migration at this load step was highest forb.a.glass + PEGwith 868 [845; 936] mu m and lowest fortetrapods + collwith 491 [487; 497] mu m. The results show a comparable behavior under load oftetrapods + colland bone chips and suggest thattetrapods + collcould be an attractive alternative to bone chips. However, so far, this was found for one specific defect type and primary stability should be further investigated in additional/more severe defects.
引用
收藏
页码:929 / 940
页数:12
相关论文
共 45 条
[21]   Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins [J].
Huber, Wolfgang O. ;
Noble, Philip C. .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) :725-731
[22]   Improving Initial Acetabular Component Stability in Revision Total Hip Arthroplasty Calcium Phosphate Cement vs Reverse Reamed Cancellous Allograft [J].
Jacofsky, David J. ;
McCamley, John D. ;
Jaczynski, Andrew M. ;
Shrader, M. Wade ;
Jacofsky, Marc C. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (02) :305-309
[23]   Does An Enhanced Surface Finish Improve Acetabular Fixation in Revision Total Hip Arthroplasty? [J].
Jamieson, Miranda L. ;
Russell, Robert D. ;
Incavo, Stephen J. ;
Noble, Philip C. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (04) :644-648
[24]   Impaction Grafting Made Easy [J].
Jones, Stephen A. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (09) :S54-S58
[25]   Processing of collagen based biomaterials and the resulting materials properties [J].
Meyer, Michael .
BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (1)
[26]   A reliable in vitro approach to assess the stability of acetabular implants using digital image correlation [J].
Morosato, F. ;
Traina, F. ;
Cristofolini, L. .
STRAIN, 2019, 55 (04)
[27]  
Morosato F, 2020, PRIMARY STABIL UNPUB
[28]   Effect of different motor tasks on hip cup primary stability and on the strains in the periacetabular bone: An in vitro study [J].
Morosato, Federico ;
Traina, Francesco ;
Cristofolini, Luca .
CLINICAL BIOMECHANICS, 2019, 70 :137-145
[29]   Acetabular revision without cement [J].
Ng, TP ;
Chiu, KY .
JOURNAL OF ARTHROPLASTY, 2003, 18 (04) :435-441
[30]   Early proximal migration of cups is associated with late revision in THA A systematic review and meta-analysis of 26 RSA studies and 49 survival studies [J].
Pijls, Bart G. ;
Nieuwenhuijse, Marc J. ;
Fiocco, Marta ;
Plevier, Josepha W. M. ;
Middeldorp, Saskia ;
Nelissen, Rob G. H. H. ;
Valstar, Edward R. .
ACTA ORTHOPAEDICA, 2012, 83 (06) :583-591