Primary stability of a press-fit cup in combination with impaction grafting in an acetabular defect model

被引:0
作者
Schierjott, Ronja A. [1 ,2 ]
Hettich, Georg [1 ]
Baxmann, Marc [1 ]
Morosato, Federico [3 ]
Cristofolini, Luca [3 ]
Grupp, Thomas M. [1 ,2 ]
机构
[1] Aesculap AG, Res & Dev Dept, Tuttlingen, Germany
[2] Ludwig Maximilians Univ Munchen, Dept Orthopaed Surg Phys Med & Rehabil, Campus Grosshadern, Munich, Germany
[3] Alma Mater Studiorum Univ Bologna, Dept Ind Engn, Bologna, Italy
关键词
acetabular bone defect model; impaction grafting; optical measurement; press-fit cup; primary stability; synthetic bone graft substitute; MORSELLIZED BONE-GRAFTS; TOTAL HIP-ARTHROPLASTY; INITIAL STABILITY; CEMENTED CUPS; REVISION; RECONSTRUCTION; PARTICLES; SURVIVORSHIP; REPLACEMENT; FIXATION;
D O I
10.1002/jor.24810
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objectives of this study were to (a) assess primary stability of a press-fit cup in a simplified acetabular defect model, filled with compacted cancellous bone chips, and (b) to compare the results with primary stability of a press-fit cup combined with two different types of bone graft substitute in the same defect model. A previously developed acetabular test model made of polyurethane foam was used, in which a mainly medial contained defect was implemented. Three test groups (N = 6 each) were prepared: Cancellous bone chips (bone chips), tricalciumphosphate tetrapods + collagen matrix (tetrapods + coll), bioactive glass S53P4 + polyethylene glycol-glycerol matrix (b.a.glass + PEG). Each material was compacted into the acetabulum and a press-fit cup was implanted. The specimens were loaded dynamically in the direction of the maximum resultant force during level walking. Relative motion between cup and test model was assessed with an optical measurement system. At the last load step (3000 N), inducible displacement was highest for bone chips with median [25th percentile; 75th percentile] value of 113 [110; 114] mu m and lowest forb.a.glass + PEGwith 91 [89; 93] mu m. Migration at this load step was highest forb.a.glass + PEGwith 868 [845; 936] mu m and lowest fortetrapods + collwith 491 [487; 497] mu m. The results show a comparable behavior under load oftetrapods + colland bone chips and suggest thattetrapods + collcould be an attractive alternative to bone chips. However, so far, this was found for one specific defect type and primary stability should be further investigated in additional/more severe defects.
引用
收藏
页码:929 / 940
页数:12
相关论文
共 45 条
[1]   Larger bone graft size and washing of bone grafts prior to impaction enhances the initial stability of cemented cups - Experiments using a synthetic acetabular model [J].
Arts, J. J. Chris ;
Verdonschot, Nico ;
Buma, Pieter ;
Schreurs, B. Willem .
ACTA ORTHOPAEDICA, 2006, 77 (02) :227-233
[2]   Comparison of the stability of three fixation techniques between porous metal acetabular components and augments [J].
Beckmann, N. A. ;
Bitsch, R. G. ;
Gondan, M. ;
Schonhoff, M. ;
Jaeger, S. .
BONE & JOINT RESEARCH, 2018, 7 (04) :282-288
[3]   Comparison of the Primary Stability of a Porous Coated Acetabular Revision Cup With a Standard Cup [J].
Beckmann, Nicholas A. ;
Jaeger, Sebastian ;
Janoszka, Maciej B. ;
Klotz, Matthias C. ;
Bruckner, Thomas ;
Bitsch, Rudi G. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (02) :580-585
[4]  
Bigoni M, 2019, EUR REV MED PHARMACO, V23, P240, DOI 10.26355/eurrev_201904_17498
[5]   Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. A study on the mechanical stability of cemented cups in an artificial acetabulum model [J].
Bolder, SBT ;
Verdonschot, N ;
Schreurs, BW ;
Buma, P .
BIOMATERIALS, 2002, 23 (03) :659-666
[6]   The initial stability of cemented acetabular cups can be augmented by mixing morsellized bone grafts with tricalciumphosphate/hydroxyapatite particles in bone impaction grafting [J].
Bolder, SBT ;
Verdonschot, N ;
Schreurs, BW ;
Buma, P .
JOURNAL OF ARTHROPLASTY, 2003, 18 (08) :1056-1063
[7]   Particle size of bone graft and method of impaction affect initial stability of cemented cups - Human cadaveric and synthetic pelvic specimen studies [J].
Bolder, SBT ;
Schreurs, BW ;
Verdonschot, N ;
van Unen, JMJ ;
Gardeniers, JWM ;
Slooff, TJJH .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (06) :652-657
[8]   COMPOSITION OF COLLAGEN AND ACID-SOLUBLE COLLAGEN OF BOVINE SKIN [J].
BOWES, JH ;
ELLIOTT, RG ;
MOSS, JA .
BIOCHEMICAL JOURNAL, 1955, 61 (01) :143-150
[9]   Differences in stiffness of the interface between a cementless porous implant and cancellous bone in vivo in dogs due to varying amounts of implant motion [J].
Bragdon, CR ;
Burke, D ;
Lowenstein, JD ;
OConnor, DO ;
Ramamurti, B ;
Jasty, M ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1996, 11 (08) :945-951
[10]   The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom [J].
Crosnier, Emilie A. ;
Keogh, Patrick S. ;
Miles, Anthony W. .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (08) :717-724