An intriguing signal-off responsive photoelectrochemical aptasensor for ultrasensitive detection of microcystin-LR and its mechanism study

被引:37
作者
Du, Xiaojiao [1 ]
Jiang, Ding [1 ]
Li, Henan [1 ]
Hao, Nan [1 ]
You, Tianyan [1 ]
Wang, Kun [1 ]
机构
[1] Jiangsu Univ, Sch Chem & Chem Engn, Key Lab Modern Agr Equipment & Technol, Zhenjiang 212013, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Photoelectrochemical; Aptasensor; Sensing mechanism; Microcystin-LR; Photoluminescence; REDUCED GRAPHENE OXIDE; NITROGEN-DOPED GRAPHENE; SENSITIVE DETECTION; GREEN SYNTHESIS; CARBON NITRIDE; QUANTUM DOTS; PERFORMANCE; BIOSENSOR; WATER; NANOPARTICLES;
D O I
10.1016/j.snb.2017.12.065
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct formatted photoelectrochemical (PEC) aptasensing platform was constructed for ultrasensitive microcystin-LR (MC-LR) detection with AgI-nitrogen-doped graphene (AgI-NG) composites as photocathode and aptamer as recognition element. The photocurrent of the AgI-NG composites was about 10.9 times higher than that of AgI. Furthermore, to investigate the sensing mechanism, the experiments with photoluminescence (PL) and time-correlated single-photon counting (TCSPC) technique were implemented as supporting evidence. The developed aptasensor can be used for MC-LR detection in fish samples. The experimental and theoretical efforts elucidate that the theory of flow directions of electron give reasonable explanation for the sensing process: prevailing electron-hole recombination constitutes a signal-off strategy, while electron transfer playing the leading role presents a signal-on performance. Impressively, we discovered that the sensing mechanism differed significantly when applied to the same analyte despite the commonality among the detecting configuration themselves, which is dependent by the interaction between the analyte MC-LR and transducer. For the detection process, in the presence of MC-LR, the specific recognition of the targets with the sensing interface would trigger the formation of the aptamer/MC-LR complex, resulting in reduced electron transfer rate, increased charge recombination, and hence quenched photocurrent intensity of the AgI-NG with detection limits of 0.017 pM. This work will help to complement the vital theoretical explanation about the underlying sensing mechanism, and future designing of PEC aptasensors. (c) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:316 / 324
页数:9
相关论文
共 48 条
[1]  
[Anonymous], 1998, GUIDELINES DRINKING, V1, P13
[2]   Highly efficient three-dimensional flower-like AgI/Bi2O2CO3 heterojunction with enhanced photocatalytic performance [J].
Chen, Jian ;
Mei, Weigang ;
Huang, Qianjin ;
Chen, Ningna ;
Lu, Chunliang ;
Zhu, Hongjun ;
Chen, Jing ;
Hou, Wenhua .
JOURNAL OF ALLOYS AND COMPOUNDS, 2016, 688 :225-234
[3]   One-Step Synthesis of the Nanostructured AgI/BiOI Composites with Highly Enhanced Visible-Light Photocatalytic Performances [J].
Cheng, Hefeng ;
Huang, Baibiao ;
Dai, Ying ;
Qin, Xiaoyan ;
Zhang, Xiaoyang .
LANGMUIR, 2010, 26 (09) :6618-6624
[4]   Enhanced photocatalytic activity and anti-photocorrosion of AgI nanostructures by coupling with graphene-analogue boron nitride nanosheets [J].
Choi, Jiha ;
Reddy, D. Amaranatha ;
Kim, Tae Kyu .
CERAMICS INTERNATIONAL, 2015, 41 (10) :13793-13803
[5]   Photoelectrochemical biosensors: New insights into promising photoelectrodes and signal amplification strategies [J].
Devadoss, Anitha ;
Sudhagar, Pitchaimuthu ;
Terashima, Chiaki ;
Nakata, Kazuya ;
Fujishima, Akira .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY C-PHOTOCHEMISTRY REVIEWS, 2015, 24 :43-63
[6]   In Situ Construction of g-C3N4/g-C3N4 Metal-Free Heterojunction for Enhanced Visible-Light Photocatalysis [J].
Dong, Fan ;
Zhao, Zaiwang ;
Xiong, Ting ;
Ni, Zilin ;
Zhang, Wendong ;
Sun, Yanjuan ;
Ho, Wing-Kei .
ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (21) :11392-11401
[7]   Fabricating photoelectrochemical aptasensor for selectively monitoring microcystin-LR residues in fish based on visible light-responsive BiOBr nanoflakes/N-doped graphene photoelectrode [J].
Du, Xiaojiao ;
Jiang, Ding ;
Dai, Liming ;
Zhou, Lei ;
Hao, Nan ;
Qian, Jing ;
Qiu, Baijing ;
Wang, Kun .
BIOSENSORS & BIOELECTRONICS, 2016, 81 :242-248
[8]   Label-Free Voltammetric Aptasensor for the Sensitive Detection of Microcystin-LR Using Graphene-Modified Electrodes [J].
Eissa, Shimaa ;
Ng, Andy ;
Siaj, Mohamed ;
Zourob, Mohammed .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :7551-7557
[9]   A Femtomolar Level and Highly Selective 17β-estradiol Photoelectrochemical Aptasensor Applied in Environmental Water Samples Analysis [J].
Fan, Lifang ;
Zhao, Guohua ;
Shi, Huijie ;
Liu, Meichuan ;
Wang, Yanbin ;
Ke, Hongyang .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (10) :5754-5761
[10]   Unique Ability of BiOBr To Decarboxylate D-Glu and D-MeAsp in the Photocatalytic Degradation of Microcystin-LR in Water [J].
Fang Yanfen ;
Huang Yingping ;
Yang Jing ;
Wang Pan ;
Cheng Genwei .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (04) :1593-1600