Effectiveness and agreement of 3 optical biometers in measuring axial length in the eyes of patients with mature cataracts

被引:15
作者
Alejandra Henriquez, Maria [1 ]
Zuniga, Raul [1 ]
Camino, Maythe [1 ]
Camargo, Jorge [1 ]
Ruiz-Montenegro, Katia [1 ]
Izquierdo Jr, Luis [1 ]
机构
[1] Oftalmosalud Inst Eyes, Res Dept, Lima, Peru
关键词
POSTERIOR CORNEAL ASTIGMATISM; REPEATABILITY;
D O I
10.1097/j.jcrs.0000000000000237
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effectiveness and agreement of 3 optical biometers in measuring axial length (AL) and biometric parameters in the eyes of patients with mature cataracts. Setting: Oftalmosalud Instituto de Ojos, Peru. Design: Prospective, comparative study. Methods: Eyes with mature cataracts were examined. Three consecutive scans were performed with each device: the IOLMaster 700, the Galilei G6, and the Pentacam AXL. The following parameters were recorded: AL, anterior flat keratometry ( K1), steep K (K2), anterior astigmatism, mean K (Km), anterior chamber depth (ACD), central corneal thickness (CCT), and lens thickness. Agreement between devices was assessed using the coefficient of correlation of concordance (CCC). Results: Forty-five eyes were included. After 3 attempts, the acquisition success rates in measuring mature cataracts were 84.4% (38/45), 42.2% (19/45), and 37.7% (17/45) for the IOLMaster, the Galilei, and the Pentacam, respectively. Significant differences were found between the Pentacam and the IOLMaster in terms of AL, K2, and CCT. Significant differences were found in terms of K1, K2, Km, ACD, and CCT between the Pentacam and the Galilei; and significant differences were found in AL, K1, Km, and ACD between the Galilei and the IOLMaster (P < .05 all). Good correlations were found between devices (>0.90) in terms of keratometries and AL. Conclusions: The IOLMaster 700 had the highest AL acquisition success rate when compared with the Pentacam AXL and Galilei G6. Good agreement between devices was found in terms of AL and K readings. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:1222 / 1228
页数:7
相关论文
共 22 条
[1]   Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500 [J].
Akman, Ahmet ;
Asena, Leyla ;
Gungor, Sirel Gur .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) :1201-1205
[2]   Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement [J].
Aramberri, Jaime ;
Araiz, Luis ;
Garcia, Ane ;
Illarramendi, Igor ;
Olmos, Jaione ;
Oyanarte, Izaskun ;
Romay, Amaya ;
Vigara, Itxaso .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11) :1934-1949
[3]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[4]   Retrochop technique for rock-hard cataracts [J].
Falabella, Paulo ;
Yogi, Milton Seiyu ;
Teixeira, Anderson ;
Jopetibe, Fernando ;
Sartori, Juliana ;
Schor, Paulo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06) :826-829
[5]   The impact of age-related cataract on measures of frailty in an aging global population [J].
Fukuoka, Hideki ;
Afshari, Natalie A. .
CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (01) :93-97
[6]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[7]  
Henriquez M, 2020, BR J OPHTHALMOL
[8]   Enhanced Penetration for Axial Length Measurement of Eyes with Dense Cataracts Using Swept Source Optical Coherence Tomography: A Consecutive Observational Study [J].
Hirnschall, Nino ;
Varsits, Ralph ;
Doeller, Birgit ;
Findl, Oliver .
OPHTHALMOLOGY AND THERAPY, 2018, 7 (01) :119-124
[9]  
Hoffer KJ, 2007, J CATARACT REFR SURG, V33, P2, DOI 10.1016/j.jcrs.2006.08.054
[10]  
Jung SJ, 2017, EVID-BASED COMPL ALT, V2017, P1