Robot-Based NDE System Using Movable HTS-SQUID Magnetometer Covered With HTS Film for Use in Unshielded Environment

被引:4
|
作者
Hatsukade, Y. [1 ,2 ]
Yoshida, K. [3 ]
Kage, T. [3 ]
Suzuki, T. [3 ]
Tanaka, S. [3 ]
机构
[1] Toyohashi Univ Technol, Toyohashi, Aichi 4418580, Japan
[2] Kinki Univ, Fac Engn, Hiroshima 7392116, Japan
[3] Toyohashi Univ Technol, Toyohashi, Aichi 4418580, Japan
关键词
Active shield; flip-chip configuration; HTS film; HTS-SQUID magnetometer; robot-based NDE system;
D O I
10.1109/TASC.2014.2362847
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a robust HTS-SQUID magnetometer utilizing bicrystal SrTiO3 substrates, single-layer YBa2Cu3O7-x films and flip-chip technique, aiming for movable robot-based NDE system in unshielded environment. Robustness in the unshielded environment was achieved by coverage of the SQUID magnetometer with another cross-shaped HTS film in flip-chip configuration, and introduction of mesh structure in both the magnetometer and the HTS film. SQUID parameters, such as critical current 2I(c), resistance R-n/2, modulation voltage depth V-PP, and flux noise S-Phi(1/2) F, were measured in DC and AC fields. The SQUID magnetometer was rotated in unshielded environment, and moved by a robot arm, resulting in stable operation during the motion at 20 mm/s with active magnetic shielding technique.
引用
收藏
页数:5
相关论文
共 46 条
  • [1] Mobile NDE System Utilizing Robust HTS-SQUID Magnetometer for Use in Unshielded Environments
    Hatsukade, Yoshimi
    Tanaka, Saburo
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
  • [2] Robot-Based NDE System Using 3D-Mobile HTS-SQUID
    Hatsukade, Yoshimi
    Yotsugi, Kohe
    Kanai, Sho
    Hayashi, Keita
    Wakana, Hironori
    Tarutani, Yoshinobu
    Tanabe, Keiichi
    Tanaka, Saburo
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 796 - 800
  • [3] Detection of deep flaws by using a HTS-SQUID in unshielded environment
    Jeng, JT
    Yang, SY
    Horng, HE
    Yang, HC
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 1295 - 1298
  • [4] Reproducibility of HTS-SQUID magnetocardiography in an unshielded clinical environment
    Leder, U
    Schrey, F
    Haueisen, J
    Dorrer, L
    Schreiber, J
    Liehr, M
    Schwarz, G
    Solbrig, O
    Figulla, HR
    Seidel, P
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2001, 79 (2-3) : 237 - 243
  • [5] HTS-SQUID magnetometer with digital feedback control for NDE applications
    Zimmermann, E
    Brandenburg, G
    Clemens, U
    Rongen, H
    Halling, H
    Krause, HJ
    Hohmann, R
    Soltner, H
    Lomparski, D
    Gruneklee, M
    Husemann, KD
    Bousack, H
    Braginski, AI
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 16A AND 16B, 1997, 16 : 2129 - 2135
  • [6] Mobile HTS-SQUID NDE system with robot arm and active shielding using fluxgate
    Hatsukade, Y.
    Yotsugi, K.
    Tanaka, S.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (15-20): : 1932 - 1935
  • [7] HTS SQUID magnetometer with SQUID vector reference for operation in unshielded environment
    He, DF
    Krause, HJ
    Zhang, Y
    Bick, M
    Soltner, H
    Wolters, N
    Wolf, W
    Bousack, H
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 3684 - 3687
  • [8] Robot-arm-based NDE of hydrogen fuel tank using a 3D-movable HTS-SQUID gradiometer
    Hatsukade, Y.
    Hayashi, K.
    Tanaka, S.
    Tanabe, K.
    9TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS 09), 2010, 234
  • [9] Development of Robust HTS-SQUID for Non-destructive Inspection System in Unshielded Environment
    Yoshida, K.
    Kage, T.
    Suzuki, T.
    Hatsukade, Y.
    Tanaka, S.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [10] Design and feasibility test of unshielded HTS-SQUID system for magnetocardiogram diagnosis
    Sakuta, K
    Fujii, T
    Ogawa, K
    Tamai, H
    Kobayashi, T
    Tonouchi, M
    Itozaki, H
    Nagaishi, T
    Kamitani, F
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 378 (PART 2): : 1391 - 1395