Optically pumped quantum Mx-MR magnetometer with high oscillating magnetic field

被引:4
作者
Ding Zhi-Chao [1 ,2 ]
Yuan Jie [1 ,2 ]
Wang Zhi-Guo [1 ,2 ]
Yang Kai-Yong [1 ,2 ]
Luo Hui [1 ,2 ]
机构
[1] Natl Univ Def Technol, Coll Optoelect Sci & Engn, Changsha 410073, Hunan, Peoples R China
[2] Natl Univ Def Technol, Interdisciplinary Ctr Quantum Informat, Changsha 410073, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
magnetic moment; linewidth; M-x-M-R magnetometer; sensitivity; RELAXATION; ATOMS;
D O I
10.1088/1674-1056/24/8/083202
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A dip of the transverse component of the magnetic moment as a function of resonance frequency-detuning will emerge when the intensity of oscillating magnetic field exceeds a specific value, which is demonstrated theoretically and experimentally. The linewidth of magnetic-resonance signal can be much smaller than when the M-x-M-R magnetometer operates on condition that the intensity of oscillating magnetic field is smaller than this specific value, and the M-x-M-R magnetometer can possess a much higher signal-to-noise ratio. The experimental result shows that the sensitivity of M-x-M-R magnetometer can be improved by an order of magnitude under this condition.
引用
收藏
页数:5
相关论文
共 14 条
[1]   Modern radio-optical methods in quantum magnetometry [J].
Aleksandrov, E. B. ;
Vershovskii, A. K. .
PHYSICS-USPEKHI, 2009, 52 (06) :573-601
[2]   Magnetic resonance for nonrotating fields [J].
Bloch, F ;
Siegert, A .
PHYSICAL REVIEW, 1940, 57 (06) :522-527
[3]   PRINCIPLES OF OPERATION OF THE RUBIDIUM VAPOR MAGNETOMETER [J].
BLOOM, AL .
APPLIED OPTICS, 1962, 1 (01) :61-68
[4]   New Limit on Lorentz- and CPT-Violating Neutron Spin Interactions [J].
Brown, J. M. ;
Smullin, S. J. ;
Kornack, T. W. ;
Romalis, M. V. .
PHYSICAL REVIEW LETTERS, 2010, 105 (15)
[5]   Resonant nonlinear magneto-optical effects in atoms [J].
Budker, D ;
Gawlik, W ;
Kimball, DF ;
Rochester, SM ;
Yashchuk, VV ;
Weis, A .
REVIEWS OF MODERN PHYSICS, 2002, 74 (04) :1153-1201
[6]   RELAXATION OF SPINS DUE TO FIELD INHOMOGENEITIES IN GASEOUS SAMPLES AT LOW MAGNETIC-FIELDS AND LOW-PRESSURES [J].
CATES, GD ;
SCHAEFER, SR ;
HAPPER, W .
PHYSICAL REVIEW A, 1988, 37 (08) :2877-2885
[7]   SLOW SPIN RELAXATION OF OPTICALLY POLARIZED SODIUM ATOMS [J].
DEHMELT, HG .
PHYSICAL REVIEW, 1957, 105 (05) :1487-1489
[8]   A high-sensitivity laser-pumped Mx magnetometer [J].
Groeger, S ;
Bison, G ;
Schenker, JL ;
Wynands, R ;
Weis, A .
EUROPEAN PHYSICAL JOURNAL D, 2006, 38 (02) :239-247
[9]   OPTICAL-PUMPING [J].
HAPPER, W .
REVIEWS OF MODERN PHYSICS, 1972, 44 (02) :169-&
[10]   A High Sensitivity Laser-Pumped Cesium Magnetometer [J].
Huang Kai-Kai ;
Li Nan ;
Lu Xuan-Hui .
CHINESE PHYSICS LETTERS, 2012, 29 (10)