On-site ion monitoring system for precision hydroponic nutrient management

被引:57
作者
Cho, Woo-Jae [1 ]
Kim, Hak-Jin [1 ,2 ]
Jung, Dae-Hyun [1 ]
Kim, Dong-Wook [1 ]
Ahn, Tae In [3 ]
Son, Jung-Eek [3 ]
机构
[1] Seoul Natl Univ, Coll Agr & Life Sci, Dept Biosyst & Biomat Engn, Seoul, South Korea
[2] Seoul Natl Univ, Res Inst Agr & Life Sci, Seoul, South Korea
[3] Seoul Natl Univ, Coll Agr & Life Sci, Dept Plant Sci, Seoul, South Korea
关键词
Closed system; Hydroponics; Ion-selective electrode (ISE); Automatic system; CAPSICUM-ANNUUM L; SELECTIVE ELECTRODES; SOILLESS CULTURES; GREENHOUSE; PAPRIKA; WATER; GROWTH; ARRAY;
D O I
10.1016/j.compag.2018.01.019
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Hydroponic solutions used in greenhouses or plant factories are usually evaluated based on their electrical conductivity (EC) and pH. However, EC and pH cannot provide sufficient information about ion imbalances in hydroponic solutions, and this may result in wastage of nutrients or poor yields. This paper reports on the development of an on-site ion monitoring system based on ion-selective electrodes (ISEs) that can automatically calibrate sensors and measure the concentrations of individual ions (NO3-, K+, and Ca2+) in hydroponic solutions. This enables farmers to effectively manage nutrients in reused solutions by rapidly identifying any imbalances that appear in the nutrient ratios. The measurement performance of the developed system was evaluated using hydroponic solutions prepared for growing paprika crops in greenhouses. An application test was conducted to investigate the feasibility of using the developed on-site ion monitoring system for the automated measurement of three macronutrients (NO3-, K+, and Ca2+) in a real greenhouse. The results showed that the developed system was able to measure NO3- concentrations, showing an almost 1:1 relationship with the results of a standard instrument, i.e., ion chromatography (slope of 0.99 and R-2 of 0.99). Although the developed system overestimated and underestimated the K+ and Ca2+ concentrations with slopes of 1.17 and 0.75, respectively, the high coefficients of determination of 0.99 and 0.97 made it possible to use calibration factors to compensate for differences in estimation. In fact, relatively low RMSEs of < 20 mg L-1 over the range of 40-1200 mg L-1 were obtained from a comparison of the ISE method and standard analysis when tested in hydroponic samples taken on different days during the period of paprika growing. This indicates that ISEs could be applicable to measurements where there is a strong linear relationship between the ISE method and standard analysis. In the application tests, the system could monitor the temporal changes in ionic concentrations in hydroponic solutions effectively, showing sensitive responses to changes in the concentrations of the three ions with an acceptable level of performance.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 24 条
  • [1] Ahn T.I., 2010, J BIOENVIRON CONTROL, V19, P298
  • [2] MONITORING NUTRIENT FILM SOLUTIONS USING ION-SELECTIVE ELECTRODES
    BAILEY, BJ
    HAGGETT, BGD
    HUNTER, A
    ALBERY, WJ
    SVANBERG, LR
    [J]. JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1988, 40 (02): : 129 - 142
  • [3] Ion-Specific Nutrient Management in Closed Systems: The Necessity for Ion-Selective Sensors in Terrestrial and Space-Based Agriculture and Water Management Systems
    Bamsey, Matthew
    Graham, Thomas
    Thompson, Cody
    Berinstain, Alain
    Scott, Alan
    Dixon, Michael
    [J]. SENSORS, 2012, 12 (10) : 13349 - 13392
  • [4] Web app for real-time monitoring of the performance of constructed wetlands treating horticultural leachates
    Caceres, Rafaela
    Pol, Enric
    Narvaez, Lola
    Puerta, Anna
    Marfa, Oriol
    [J]. AGRICULTURAL WATER MANAGEMENT, 2017, 183 : 177 - 185
  • [5] AN EMBEDDED SYSTEM FOR AUTOMATED HYDROPONIC NUTRIENT SOLUTION MANAGEMENT
    Cho, W. J.
    Kim, H. J.
    Jung, D. H.
    Kang, C. I.
    Choi, G. L.
    Son, J. E.
    [J]. TRANSACTIONS OF THE ASABE, 2017, 60 (04) : 1083 - 1096
  • [6] Automated system developed to control pH and concentration of nutrient solution evaluated in hydroponic lettuce production
    Domingues, Diego S.
    Takahashi, Hideaki W.
    Camara, Carlos A. P.
    Nixdorf, Suzana L.
    [J]. COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2012, 84 : 53 - 61
  • [7] Computer-controlled system for ISEs automatic calibration
    Dorneanu, SA
    Coman, V
    Popescu, IC
    Fabry, P
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02) : 521 - 531
  • [8] Influence of Ca2+, K+ and NO3-fertilisation on nutritional quality of pepper
    Flores, P
    Navarro, JM
    Garrido, C
    Rubio, JS
    Martínez, V
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2004, 84 (06) : 569 - 574
  • [9] 김학진, 2011, Journal of Biosystems Engineering, V36, P326
  • [10] Jung DH, 2015, T ASABE, V58, P1309